| Literature DB >> 33939323 |
Chiara Del Prete1, Francesca Freccero2, Aliai Lanci2, Gayle D Hallowell3, Chiara Bullone4, Carolina Castagnetti2,5, Maria Pia Pasolini1.
Abstract
BACKGROUND: Ultrasonographic measurement of the vena cava and aorta (Ao) diameters and their ratios have been suggested to be a reliable way of quantifying hypovolemia.Entities:
Keywords: caudal vena cava/aorta ratios; foals; intravascular volume; ultrasound
Mesh:
Year: 2021 PMID: 33939323 PMCID: PMC8464261 DOI: 10.1002/vms3.506
Source DB: PubMed Journal: Vet Med Sci ISSN: 2053-1095
FIGURE 1Left dorsal view (View 1): (a) transducer placement site and (b) ultrasonographic measurements of cross‐sectional diameters of the aorta and of the long and short axis of the caudal vena cava
FIGURE 2Right view (View 3): (a) transducer placement site and (b) ultrasonographic measurements of cross‐sectional diameters of the aorta and of the long and short axis of the caudal vena cava
FIGURE 3Left ventral view (View 2): (a) transducer placement site and (b) ultrasonographic measurements of cross‐sectional diameters of the aorta and of the long and short axis of the caudal vena cava
Four‐point scale used to score the image quality of the cineloops of Ao and CVC in cross sections obtained using three ultrasonographic imaging planes in healthy neonatal foals
| Scores | |
|---|---|
| 0 | Poor visualization |
| 1 | Both vessels unclear (i.e., gas within the intestinal tract obscuring all or part of the vessels) |
| 2 | Margins of ventral vessel unclear |
| 3 | Well‐defined visualization of both vessels |
FIGURE 4Graphic representation and table of the percentage of images of Ao and CVC assigned to each quality score for the left dorsal, left ventral and right ultrasonographic views. The imaging quality of cineloops was scored on a four‐point scale (0 = poor visualization, 1 = both vessels unclear, 2 = ventral vessel unclear and 3 = well‐defined visualization of both vessels) by observers A and B independently
Interobserver reliability for imaging quality score and intraobserver and interobserver reliabilities for ultrasonographic measurements of Ao and CVC obtained using three ultrasonographic views (left dorsal, left ventral and right) in healthy neonatal foals
| Left dorsal view | Left ventral view | Right view | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Quality score | Ao diameter | CVC long axis | CVC short axis | Quality score | Ao diameter | CVC long axis | CVC short axis | Quality Score | Ao diameter | CVC long axis | CVC short axis | |
|
Intraobserver reliability (Observer A) | / | 0.78 (0.31–0.92) | 0.90 (0.68–0.97) | 0.90 (0.71–9.70) | / | 0.91 (7.55–9.73) | 0.87 (0.65–0.96) | 0.98 (0.94–0.99) | / | 0.92 (0.75–0.97) | 0.70 (0.27–0.91) | 0.88 (0.63–0.96) |
| Intraobserver reliability (Observer B) | / | 0.95 (0.85–0.98) | 0.84 (0.51–0.95) | 0.90 (0.71–0.97) | / | 0.91 (0.74–0.97) | 0.93 (0.78–0.98) | 0.91 (0.72–0.97) | / | 0.76 (0.23–0.93) | 0.93 (0.80–0.98) | 0.92 (0.76–0.98) |
|
Interobserver reliability (A vs. B) | 1.09 (−0.36 to 0.58) | 0.81 (0.40 to 0.94) | 0.59 (−0.34 to 0.87) | 0.79 (0.33–0.93) | 0.57 (0.21–0.92) | 0.91 (0.73–0.97) | 0.85 (0.54–0.95) | 0.89 (0.67–0.96) | 0.27 (−0.93 to 0.64) | 0.32 (−1.37 to 0.79) | 0.71 (0.09–0.91) | 0.90 (0.70–0.97) |
κ and ICC values: <0 no agreement, 0.20 slight agreement, 0.21–0.40 fair agreement, 0.41–0.60 moderate agreement, 0.61–0.80 substantial agreement and 0.81–1.0 almost perfect agreement. ICC values: <0.5 poor reliability, 0.5–0.75 moderate reliability, 0.75–0.9 good reliability and >0.90 excellent reliability.
Abbreviations: Ao, aorta; CVC, caudal vena cava; ICC, intraclass correlation coefficient.
Ultrasonographic measurements and calculated variables obtained on images from the left ventral view (View 2) by two observers in healthy neonatal foals
| Mean ± | Ao diameter (mm) | CVC long axis (mm) | CVC short axis (mm) | CVC/Ao diameter index | Ao area (mm2) | CVC area (mm2) | CVC/Ao area index |
|---|---|---|---|---|---|---|---|
| Observer A | 16.0 ± 2.1 | 16.5 ± 2.5 | 14.1 ± 4 | 10.5 ± 1.9 | 20.7 ± 5.4 | 16.4 (13.8–19.8) | 9.1 ± 2.8 |
| Observer B | 16.4 ± 1.6 | 17.1 ± 3.7 | 14.9 ± 3.0 | 10.6 ± 2.5 | 21.2 ± 4.2 | 18.8 (16.1–21.4) | 9.7 ± 3.6 |
| A–B mean | 16.2 ± 1.8 | 16.8 ± 2.9 | 14.5 ± 3.4 | 10.5 ± 2.1 | 21 ± 4.6 | 18.0 (14.5–21) | 9.4 ± 3 |
Measured variables: Ao diameter, CVC long axis diameter and CVC short axis diameter. Calculated variables: CVC/Ao diameter index: CVC long axis/Ao diameter; Ao area: 3.14 × (½ of the Ao diameter)2; CVC area: 3.14 × ½ CVC long axis × ½ CVC short axis; CVC/Ao area index: CVC area/ Ao area. N = 14 foals.
FIGURE 5Linear correlation between foals' body weight (kg) and the short axis diameter of CVC (mm) (R 2 = 0.385; β = 0.620; p = 0.018)
FIGURE 6(a) Linear correlation between foals' age (h) and CVC long axis diameter (mm) (R 2 = 0.426; β = 0.653; p = 0.011) and (b) the CVC/Ao diameter index (R 2 = 0.625; β = 0.808; p = 0.001)