Literature DB >> 27027706

Correlation of the ratio of caudal vena cava diameter and aorta diameter with systolic pressure variation in anesthetized dogs.

Caterina Meneghini, Roberto Rabozzi, Paolo Franci.   

Abstract

OBJECTIVE: To evaluate the correlation coefficient of the ratio between diameter of the caudal vena cava (CVC) and diameter of the aorta (Ao) in dogs as determined ultrasonographically with systolic pressure variation (SPV). ANIMALS: 14 client-owned dogs (9 females and 5 males; mean ± SD age, 73 ± 40 months; mean body weight, 22 ± 7 kg) that underwent anesthesia for repair of skin wounds. PROCEDURES: Anesthesia was induced. Controlled mechanical ventilation with a peak inspiratory pressure of 8 cm H2O was immediately started, and SPV was measured. During a brief period of suspension of ventilation, CVC-to-Ao ratio was measured on a transverse right-lateral intercostal ultrasonographic image obtained at the level of the porta hepatis. When the SPV was ≥ 4 mm Hg, at least 1 bolus (3 to 4 mL/kg) of Hartmann solution was administered IV during a 1-minute period. Bolus administration was stopped and the CVC-to-Ao ratio measured when SPV was < 4 mm Hg. Correlation coefficient analysis was performed.
RESULTS: 28 measurements were obtained. The correlation coefficient was 0.86 (95% confidence interval, 0.72 to 0.93). Mean ± SD SPV and CVC-to-Ao ratio before bolus administration were 7 ± 2 mm Hg and 0.52 ± 0.16, respectively. Mean ± SD SPV and CVC-to-Ao ratio after bolus administration were 2 ± 0.6 mm Hg and 0.91 ± 0.13, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: In this study, the CVC-to-Ao ratio was a feasible, noninvasive ultrasonographically determined value that correlated well with SPV.

Entities:  

Mesh:

Year:  2016        PMID: 27027706     DOI: 10.2460/ajvr.77.2.137

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  5 in total

1.  Ultrasound measurements of the caudal vena cava before and after blood donation in 9 greyhound dogs.

Authors:  Kristen A Marshall; Elizabeth J Thomovsky; Aimee C Brooks; Paula A Johnson; Chee Kin Lim; Hock Gan Heng
Journal:  Can Vet J       Date:  2018-09       Impact factor: 1.008

2.  Ultrasonographic assessment of the caudal vena cava diameter in cats during blood donation.

Authors:  Florian Sänger; Roswitha Dorsch; Katrin Hartmann; René Dörfelt
Journal:  J Feline Med Surg       Date:  2021-07-27       Impact factor: 1.971

3.  Ultrasonographical Assessment of Caudal Vena Cava Size through Different Views in Healthy Calves: A Pilot Study.

Authors:  Hélène Casalta; Valeria Busoni; Justine Eppe; Sigrid Grulke; Anne-Christine Merveille; Nassim Moula; Kris Gommeren
Journal:  Vet Sci       Date:  2022-06-22

4.  Establishment of reference values of the caudal vena cava by fast-ultrasonography through different views in healthy dogs.

Authors:  Elodie Darnis; Soren Boysen; Anne-Christine Merveille; Loïc Desquilbet; Serge Chalhoub; Kris Gommeren
Journal:  J Vet Intern Med       Date:  2018-05-10       Impact factor: 3.333

5.  Transabdominal ultrasonographic measurement of caudal vena cava to aorta derived ratios in clinically healthy neonatal foals.

Authors:  Chiara Del Prete; Francesca Freccero; Aliai Lanci; Gayle D Hallowell; Chiara Bullone; Carolina Castagnetti; Maria Pia Pasolini
Journal:  Vet Med Sci       Date:  2021-05-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.