OBJECTIVE: Current studies have not found sufficient evidence to encourage the use of ultrasound for assessing dehydration in children. We introduce a new sonographic parameter, the "aorta/inferior vena cava (IVC) cross-sectional area index" (Ao/IVCA) measured just inferior to the xiphoid process, for the effective evaluation of dehydration in children.
METHODS: This is a prospective, observational study. We enrolled children who presented to the pediatric emergency department (PED) between May 2014 and January 2015. We measured the maximum diameter of the aorta from inner wall to inner wall, and the long and short axis diameters of IVC using a convex array transducer. Ao/IVCA was calculated and compared with aorta/IVC maximal diameter index (Ao/IVCD) and the clinical dehydration scale (CDS).
RESULTS: A total of 34 children were enrolled. We found a statistically significant correlation between Ao/IVCA and CDS (R(2) = 0.30; P <.001). Ao/IVCD did not correlate significantly with CDS (R(2) = 0.08; P =.11). The ability of Ao/IVCA and Ao/IVCD to predict CDS ≥1 was assessed using the receiver operating characteristic analysis. The area under the receiver operating characteristic curve for Ao/IVCA was larger than that for Ao/IVCD (0.87 vs 0.75, P= .04). The cut-off value of Ao/IVCA that yielded the maximum value of Youden index was 1.81 (sensitivity: 72%, specificity: 89%).
CONCLUSIONS: Ao/IVCA might be a promising index for the assessment of dehydration. The diagnostic performance of Ao/IVCA for dehydration might be higher than that of the method that uses the maximum diameter of IVC and the aorta.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27339224     DOI: 10.1016/j.ajem.2016.06.060

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  5 in total

1.  Ultrasonographical Assessment of Caudal Vena Cava Size through Different Views in Healthy Calves: A Pilot Study.

Authors:  Hélène Casalta; Valeria Busoni; Justine Eppe; Sigrid Grulke; Anne-Christine Merveille; Nassim Moula; Kris Gommeren
Journal:  Vet Sci       Date:  2022-06-22

2.  Point-of-care ultrasound in pediatric nephrology.

Authors:  Sidharth Kumar Sethi; Rupesh Raina; Abhilash Koratala; Afagh Hassanzadeh Rad; Ananya Vadhera; Hamidreza Badeli
Journal:  Pediatr Nephrol       Date:  2022-09-26       Impact factor: 3.651

3.  Establishment of reference values of the caudal vena cava by fast-ultrasonography through different views in healthy dogs.

Authors:  Elodie Darnis; Soren Boysen; Anne-Christine Merveille; Loïc Desquilbet; Serge Chalhoub; Kris Gommeren
Journal:  J Vet Intern Med       Date:  2018-05-10       Impact factor: 3.333

4.  Transabdominal ultrasonographic measurement of caudal vena cava to aorta derived ratios in clinically healthy neonatal foals.

Authors:  Chiara Del Prete; Francesca Freccero; Aliai Lanci; Gayle D Hallowell; Chiara Bullone; Carolina Castagnetti; Maria Pia Pasolini
Journal:  Vet Med Sci       Date:  2021-05-03

5.  Interobserver Agreement of Inferior Vena Cava Ultrasound Collapse Duration and Correlated Outcomes in Children With Dehydration.

Authors:  Amy Z Zhou; Robert S Green; Elizabeth J Haines; Michelle N Vazquez; Ee T Tay; James W Tsung
Journal:  Pediatr Emerg Care       Date:  2022-01-01       Impact factor: 1.454

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.