Literature DB >> 29343170

Accuracy of Ultrasonographic Measurements of Inferior Vena Cava to Determine Fluid Responsiveness: A Systematic Review and Meta-Analysis.

Daniele Orso1, Irene Paoli1, Tommaso Piani2, Francesco L Cilenti1, Lorenzo Cristiani1, Nicola Guglielmo1.   

Abstract

OBJECTIVE: Fluid responsiveness is the ability to increase the cardiac output in response to a fluid challenge. Only about 50% of patients receiving fluid resuscitation for acute circulatory failure increase their stroke volume, but the other 50% may worsen their outcome. Therefore, predicting fluid responsiveness is needed. In this purpose, in recent years, the assessment of the inferior vena cava (IVC) through ultrasound (US) has become very popular. The aim of our work was to systematically review all the previously published studies assessing the accuracy of the diameter of IVC or its respiratory variations measured through US in predicting fluid responsiveness. DATA SOURCES: We searched in the MEDLINE (PubMed), Embase, Web of Science databases for all relevant articles from inception to September 2017. STUDY SELECTION: Included articles specifically addressed the accuracy of IVC diameter or its respiratory variations assessed by US in predicting the fluid responsiveness in critically ill ventilated or not, adult or pediatric patients. DATA EXTRACTION: We included 26 studies that investigated the role of the caval index (IVC collapsibility or distensibility) and 5 studies on IVC diameter. DATA SYNTHESIS: We conducted a meta-analysis for caval index with 20 studies: The pooled area under the curve, logarithmic diagnostic odds ratio, sensitivity, and specificity were 0.71 (95% confidence interval [CI]: 0.46-0.83), 2.02 (95% CI: 1.29-2.89), 0.71 (95% CI: 0.62-0.80), and 0.75 (95% CI: 0.64-0.85), respectively.
CONCLUSION: An extreme heterogeneity of included studies was highlighted. Ultrasound evaluation of the diameter of the IVC and its respiratory variations does not seem to be a reliable method to predict fluid responsiveness.

Entities:  

Keywords:  fluid responsiveness; inferior vena cava; meta-analysis; review

Mesh:

Year:  2018        PMID: 29343170     DOI: 10.1177/0885066617752308

Source DB:  PubMed          Journal:  J Intensive Care Med        ISSN: 0885-0666            Impact factor:   3.510


  34 in total

Review 1.  Heart failure and sepsis: practical recommendations for the optimal management.

Authors:  Angelos Arfaras-Melainis; Eftihia Polyzogopoulou; Filippos Triposkiadis; Andrew Xanthopoulos; Ignatios Ikonomidis; Alexander Mebazaa; John Parissis
Journal:  Heart Fail Rev       Date:  2020-03       Impact factor: 4.214

2.  Internal jugular vein ultrasound for the diagnosis of hypovolemia and hypervolemia in acutely ill adults: a systematic review and meta-analysis.

Authors:  Michael Ke Wang; Joshua Piticaru; Coralea Kappel; Michael Mikhaeil; Lawrence Mbuagbaw; Bram Rochwerg
Journal:  Intern Emerg Med       Date:  2022-06-20       Impact factor: 5.472

3.  Comparison of inferior vena cava collapsibility and central venous pressure in assessing volume status in shocked patients.

Authors:  Monira T Ismail; Afaf A El-Iraky; Emad El-Din A Ibrahim; Tarek H El Kammash; Ahmed E Abou-Zied
Journal:  Afr J Emerg Med       Date:  2022-05-17

4.  Case Report: Tachycardia, Hypoxemia and Shock in a Severely Burned Pediatric Patient.

Authors:  Jianshe Shi; Chuheng Huang; Jialong Zheng; Yeqing Ai; Hiufang Liu; Zhiqiang Pan; Jiahai Chen; Runze Shang; Xinya Zhang; Shaoliang Dong; Rongkai Lin; Shurun Huang; Jianlong Huang; Chenghua Zhang
Journal:  Front Cardiovasc Med       Date:  2022-06-16

5.  Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery.

Authors:  Qian Ma; Jingjing Ji; Xueduo Shi; Ziyun Lu; Lu Xu; Jing Hao; Wei Zhu; Bingbing Li
Journal:  BMC Anesthesiol       Date:  2022-05-17       Impact factor: 2.376

6.  Performance of a 25% Inferior Vena Cava Collapsibility in Detecting Fluid Responsiveness When Assessed by Novice Versus Expert Physician Sonologists.

Authors:  Keith A Corl; Nader Azab; Mohammed Nayeemuddin; Alexandra Schick; Thomas Lopardo; Fatima Zeba; Gary Phillips; Grayson Baird; Roland C Merchant; Mitchell M Levy; Michael Blaivas; Adeel Abbasi
Journal:  J Intensive Care Med       Date:  2019-10-14       Impact factor: 3.510

7.  Assessment of end-tidal carbon dioxide and vena cava collapsibility in volume responsiveness in spontaneously breathing patients.

Authors:  S Güney Pınar; M Pekdemir; I U Özturan; N Ö Doğan; E Yaka; S Yılmaz; A Karadaş; D Ferek Emir
Journal:  Med Klin Intensivmed Notfmed       Date:  2020-10-25       Impact factor: 0.840

8.  The role of mitral annular plane systolic excursion in prediction of acute blood loss in healthy voluntary blood donors.

Authors:  Birdal Güllüpınar; Caner Sağlam; Serhat Koran; Ajda Turhan; Erden Erol Ünlüer
Journal:  J Ultrason       Date:  2022-02-08

9.  Comparison of cardiac output, IVC diameters and lactate levels in prediction of mortality in patients in emergency department; An observational study.

Authors:  Kavous Shahsavarinia; Ali Taqizadieh; Payman Moharramzadeh; Ramin Amirchoupani; Ata Mahmoodpoor
Journal:  Pak J Med Sci       Date:  2020 May-Jun       Impact factor: 1.088

10.  Tricuspid annular plane systolic excursion and central venous pressure in mechanically ventilated critically ill patients.

Authors:  Hongmin Zhang; Xiaoting Wang; Xiukai Chen; Qing Zhang; Dawei Liu
Journal:  Cardiovasc Ultrasound       Date:  2018-08-07       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.