| Literature DB >> 35227312 |
Olena Al-Shymali1, Colm McAlinden2, Jorge L Alio Del Barrio3, Mario Canto-Cerdan1, Jorge L Alio4,5.
Abstract
BACKGROUND: The aim of the study was to evaluate the outcomes of dissatisfied patients reporting poor visual quality following implantation of multifocal intraocular lenses (MF-IOLs), managed by IOL exchange with another multifocal optical profile.Entities:
Year: 2022 PMID: 35227312 PMCID: PMC8887122 DOI: 10.1186/s40662-022-00280-8
Source DB: PubMed Journal: Eye Vis (Lond) ISSN: 2326-0254
Patients’ data
| Patient No. | Gender | Age (years) | Eye | MF1 | MF2 | T(m) | Repeat surgery |
|---|---|---|---|---|---|---|---|
| 1 | M | 63 | R | Lentis Mplus LS-313 MF 15 | AT LISA tri 839MP | 3 | Yes |
| L | Lentis Mplus LS-313 MF 30 | AT LISA tri 839MP | 3 | ||||
| 2 | M | 58 | R | AcrySof IQ ReSTOR SN6AD1 | Lentis Mplus LS-313 MF30 | 3 | Yes |
| L | AcrySof IQ ReSTOR SN6AD1 | Lentis Mplus LS-313 MF15 | 3 | ||||
| 3 | M | 47 | R | Mini Well Ready | Lentis Mplus LS-313 MF 15 | 9 | Yes |
| L | Mini Well Ready | Lentis Mplus LS-313 MF 30 | 9 | ||||
| 4 | F | 67 | R | AcrySof IQ PanOptix TFNT00 | Lentis Mplus LS-313 MF 30 | 7 | Yes |
| L | AcrySof IQ PanOptix TFNT00 | Lentis Mplus LS-313 MF15 | 3 | ||||
| 5 | F | 54 | R | Lentis Mplus LS-313 MF 30 | AT LISA tri 839MP | 26 | Yes |
| L | Lentis Mplus LS-313 MF 30 | AT LISA tri 839MP | 26 | ||||
| 6 | F | 55 | R | M-flex 630-F | AT LISA tri 839MP | 12 | Yes |
| L | M-flex 630-F | AT LISA tri 839MP | 12 | ||||
| 7 | F | 62 | R | MiniWell Ready | AT LISA tri 839MP | 3 | Yes |
| L | MiniWell Ready | AT LISA tri 839MP | 3 | ||||
| 8 | M | 54 | R | MiniWell Ready | Lentis Mplus LS-313 MF 15 | 3 | Yes |
| L | MiniWell Ready | Lentis Mplus LS-313 MF 15 | 3 | ||||
| 9 | F | 62 | R | Lentis Mplus LS-313 MF 30 | AT LISA 809 M | 3 | No |
| L | Lentis Mplus LS-313 MF 30 | Acri Lisa 366D | 3 | ||||
| 10 | F | 70 | R | AcrySof IQ ReSTOR SN6AD3 | Lentis Mplus LS-313 MF 30 | 89 | Yes |
| L | AcrySof IQ ReSTOR SN6AD3 | Lentis Mplus LS-313 MF 30 | 89 | ||||
| 11 | F | 61 | R | Lentis Mplus LS 313 MF 15 | AcrySof IQ PanOptix TFNT00 | 5 | No |
| L | Lentis Mplus LS-313 MF 30 | AcrySof IQ PanOptix TFNT00 | 4 | ||||
| 12 | F | 57 | R | Precizon Presbyopic | AT LISA tri 839MP | 7 | Yes |
| L | Precizon Presbyopic | AT LISA tri 839MP | 7 | ||||
| 13 | M | 50 | R | Precizon Presbyopic | FineVision Pod F | 3 | Yes |
| L | Precizon Presbyopic | FineVision Pod F | 3 | ||||
| 14 | F | 47 | R | Acunex Vario | AT LISA tri 839MP | 3 | Yes |
| L | Lentis Mplus LS 313 MF 15 | AT LISA tri 839MP | 3 | ||||
| 15 | M | 57 | R | Precizon Presbyopic | Intensity SL HP | 3 | No |
| L | Precizon Presbyopic | Intensity SL HP | 3 |
MF1 = the first multifocal intraocular lens; MF2 = the second multifocal intraocular lens; T(m) = time between implantation and explantation in months; M = male; F = female; R = right; L = left
Multifocal intraocular lenses physical design description
| IOL model | IOL type | IOL physical design description |
|---|---|---|
| Lentis Mplus LS-313 MF (Oculentis) | Refractive | Optic size: 6.0 mm Overall size: 11.0 mm Haptic style: plate with 0° angulation |
| AT LISA tri 839MP (Zeiss) | Diffractive | Optic size: 6.0 mm Overall size: 11.0 mm Haptic style: plate with 0° angulation |
| AcrySof IQ ReSTOR SN6AD1/D3 (Alcon) | Diffractive | Optic size: 6.0 mm Overall size: 13.0 mm Haptic style: STABLEFORCE® Modified-L Haptics with 0° angulation Diffractive steps: 9 |
| Mini Well Ready (Sifi Medtech) | EDOF | Optic size: 6.0 mm Overall size: 10.75 mm Haptic style: Four haptics in closed double–C loop with 5° haptic angulation |
| AcrySof IQ PanOptix TFNT00 (Alcon) | Diffractive | Optic size: 6.0 mm Overall size: 13.0 mm Haptic style: STABLEFORCE™ Modified-L Haptics with 0° angulation |
| AT Lisa 809 M (Zeiss) | Diffractive | Optic size: 6.0 mm Overall size: 11.0 mm Haptic style: plate with 0° angulation |
| FineVision Pod F (PhysIOL) | Diffractive | Optic size: 6.0 mm Overall size: 11.4 mm Haptic style: double C-loop haptics with 5° haptic angulation |
| M-flex 630-F (Rayner) | Refractive | Optic size: 6.25 mm Overall size: 12.5 mm Haptic style: Closed loop with anti-vaulting haptic with 0° haptic angulation |
| Precizon Presbyopic (Ophtec BV) | Refractive | Optic size: 6.0 mm Overall size: 12.5 mm Haptic style: open modified-C loops with offset-shaped haptics with 0° angulation |
| Acri Lisa 366D (Zeiss) | Diffractive | Optic size: 6.0 mm Overall size: 11.0 mm Haptic style: plate with 0° angulation |
| Acunex Vario (Teleon Surgical) | EDOF | Optic size: 6.0 mm Overall size: 12.5 mm Haptic style: C-loop haptics with 0° angulation |
| Intensity SL HP (Hanita Lenses) | Diffractive | Optic size: 6.0 mm Overall size: 13.0 mm Haptic style: C-loop haptics with 5° angulation |
IOL = intraocular lens; EDOF = extended depth of focus
Refractive and visual outcomes following the first multifocal intraocular lens (MF1) and the second multifocal intraocular lens (MF2) implantation
| MF1 | MF2 | ||||
|---|---|---|---|---|---|
| Mean ± SD | Range | Mean ± SD | Range | ||
| UDVA (logMAR) | 0.24 ± 0.61 | 1.7–0.0 | 0.12 ± 0.77 | 0.44–0.00 | < 0.001 |
| CDVA (logMAR) | 0.15 ± 0.57 | 1.7–0.0 | 0.04 ± 0.98 | 0.26–0.00 | < 0.001 |
| Sph (D) | 0.21 ± 0.67 | − 1.00–1.25 | 0.38 ± 0.44 | − 0.50–1.50 | 0.111 |
| Cyl (D) | − 0.35 ± 0.49 | − 1.25–1.25 | − 0.68 ± 0.45 | − 1.50–0.00 | 0.010 |
| SE (D) | 0.03 ± 0.59 | − 1.00–1.00 | 0.04 ± 0.43 | − 0.75–1.00 | 0.884 |
| UNVA (logMAR) | 0.31 ± 0.66 | 1.4–0.0 | 0.28 ± 0.68 | 0.62–0.00 | 0.076 |
| DCNVA (logMAR) | 0.26 ± 0.56 | 1.4–0.0 | 0.20 ± 0.62 | 0.52–0.00 | 0.235 |
UDVA = uncorrected distance visual acuity; CDVA = corrected distance visual acuity; Sph = sphere; Cyl = cylinder; SE = spherical equivalent; UNVA = uncorrected near visual acuity; DCNVA = distance-corrected near visual acuity; SD = standard deviation
Quality of Vision questionnaire Rasch score
| Preoperative score (mean ± SD) | Postoperative score (mean ± SD) | ||
|---|---|---|---|
| Frequency | 61.27 ± 16.42 | 35.87 ± 29.40 | 0.012 |
| Severity | 54.20 ± 17.83 | 34.20 ± 32.26 | 0.042 |
| Bothersome | 59.67 ± 18.13 | 32.33 ± 35.97 | 0.019 |
Scores of the patients before the exchange of a multifocal IOL and after the exchange to another multifocal IOL. The greater the score (maximum 100), the worse is the quality of vision. SD = standard deviation
Visual Function Index-14 questionnaire score
| Preoperative score (mean ± SD) | Postoperative score (mean ± SD) | ||
|---|---|---|---|
| Total score | 60.41 ± 24.81 | 90.16 ± 10.91 | < 0.001 |
| Far distance | 61.55 ± 22.98 | 89.70 ± 13.03 | < 0.001 |
| Intermediate distance | 68.89 ± 26.63 | 97.50 ± 7.01 | 0.001 |
| Near distance | 58.00 ± 30.17 | 86.00 ± 14.78 | 0.004 |
Mean scores of the patients before the exchange of a multifocal IOL and after the exchange to another multifocal IOL. The greater the score (maximum 100), the better is the visual function. SD = standard deviation
Percentage of patients answering 4 questions regarding their overall satisfaction with their vision for different distances, their willingness to repeat the surgery, their spectacle independency, and the frequency of spectacle use, all with the first multifocal intraocular lens (MF1) versus the second multifocal intraocular lens (MF2)
| What was your overall satisfaction with the vision? | ||||||
| With MF1 | With MF2 | |||||
| Far (%) | Intermediate (%) | Near (%) | Far (%) | Intermediate (%) | Near (%) | |
| Very good | 6.67 | 0.00 | 0.00 | 20.00 | 46.67 | 33.33 |
| Good | 13.33 | 26.67 | 26.67 | 60.00 | 26.67 | 33.33 |
| Average | 40.00 | 40.00 | 33.33 | 0.00 | 6.67 | 13.33 |
| Bad | 0.00 | 6.67 | 6.67 | 13.33 | 13.33 | 20.00 |
| Very bad | 40.00 | 26.67 | 33.33 | 6.67 | 6.67 | 0.00 |
| Would you repeat the surgery? | ||||||
| With MF1 (%) | With MF2 (%) | |||||
| Yes | 13.33 | 80.00 | ||||
| No | 86.67 | 20.00 | ||||
| Were you spectacle independent? | ||||||
| With MF1 | With MF2 | |||||
| Far (%) | Intermediate (%) | Near (%) | Far (%) | Intermediate (%) | Near (%) | |
| Yes | 86.67 | 80.00 | 60.00 | 93.33 | 93.33 | 73.33 |
| No | 13.33 | 20.00 | 40.00 | 6.67 | 6.67 | 26.67 |
| How often you used spectacles? | ||||||
| With MF1 | With MF2 | |||||
| Far (%) | Intermediate (%) | Near (%) | Far (%) | Intermediate (%) | Near (%) | |
| Never | 93.33 | 86.67 | 66.67 | 100.00 | 100.00 | 66.67 |
| Almost never | 6.67 | 6.67 | 6.67 | 0.00 | 0.00 | 6.67 |
| Sometimes | 0.00 | 0.00 | 6.67 | 0.00 | 0.00 | 0.00 |
| Almost always | 0.00 | 0.00 | 6.67 | 0.00 | 0.00 | 0.00 |
| Always | 0.00 | 6.67 | 13.33 | 0.00 | 0.00 | 26.67 |