| Literature DB >> 35706684 |
Stephen A Stewart1,2, Richard N McNeely1, Wing C Chan1, Jonathan E Moore1,3,4.
Abstract
Purpose: To assess the visual and refractive outcomes following exchange of an opacified multifocal intraocular lens (IOL). Patients andEntities:
Keywords: IOL exchange; cataract surgery; multifocal IOL; opacified IOL
Year: 2022 PMID: 35706684 PMCID: PMC9191835 DOI: 10.2147/OPTH.S362930
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1Diffusely opacified Lentis Mplus IOL prior to explantation.
Demographics and Baseline Characteristics
| Preoperative | |
|---|---|
| No. of patients (eyes) | 31 (37) |
| Age (y), mean ± SD (range) | 69 ± 9.2 (52 to 88) |
| Gender, male/female (%) | 15/16 (48/52) |
| Time (y) from initial implant to exchange, mean ± SD (range) | 7.1 ± 1.6 (4.1 to 9.5) |
| Sphere (D) | 0.23 ± 0.62 (−0.75 to 2.00) |
| Cylinder (D) | −0.29 ± 0.43 (−1.50 to 0.00) |
| MSE (D) | 0.08 ± 0.57 (−1.00 to 1.25) |
| UDVA (logMAR) | 0.23 ± 0.20 (−0.10 to 0.80) |
| CDVA (logMAR) | 0.13 ± 0.15 (−0.14 to 0.46) |
Abbreviations: MSE, mean spherical equivalent; UDVA, unaided distance visual acuity; CDVA, corrected distance visual acuity.
Model, Design and Implant Location of Secondary IOLs
| Location of Secondary IOL | ||||
|---|---|---|---|---|
| Model/Design | Bag | Sulcus | Sulcus (+OC) | Iris |
| Alcon AcrySof IQ/1-piece monofocal | 2 | – | – | – |
| Zeiss CT Asphina 409MP/1-piece monofocal | 1 | – | – | – |
| Tecnis ZA9003/3-piece monofocal | – | 2 | 1 | – |
| Zeiss EC-3 PAL/3-piece monofocal | – | 3 | 4 | – |
| Zeiss CT Lucia 202/3-piece monofocal | – | 6 | – | – |
| Ophtec Artisan/Iris claw monofocal | – | – | – | 2 |
| Lenstec SBL-3/1-piece bifocal | 1 | – | – | – |
| Lentis Mplus LU-814 MF30/1-piece multifocal with 4 open loop haptics | – | 6 | – | – |
| Alcon Panoptix/1-piece multifocal | 9 | – | – | – |
| 13 | 17 | 5 | 2 | |
Abbreviation: OC, optic capture.
Visual Outcomes Following IOL Exchange
| Postoperative Visit 1 | Postoperative Visit 2 | |||
|---|---|---|---|---|
| Secondary IOL | Monofocal (n = 21) | Multifocal (n = 16) | Monofocal (n = 19) | Multifocal (n = 10) |
| Mean time to follow-up (weeks) | 4.5 ± 2.3 | 4.1 ± 1.1 | 39.1 ± 25.7 | 30.0 ± 14.7 |
| Sphere (D) | −0.23 ± 0.88 (−1.75 to 1.50) | −0.08 ± 0.47 (−1.00 to 0.75) | −0.31 ± 0.74 (−1.75 to 1.25) | −0.05 ± 0.63 (−1.00 to 1.25) |
| Cylinder (D) | −0.64 ± 0.55 (−2.25 to 0.00) | −0.58 ± 0.42 (−1.50 to 0.00) | −0.56 ± 0.50 (−1.50 to 0.00) | −0.60 ± 0.64 (−2.00 to 0.00) |
| MSE (D) | −0.54 ± 0.80 (−2.00 to 1.00) | −0.37 ± 0.50 (−1.13 to 0.50) | −0.58 ± 0.74 (−2.00 to 0.75) | −0.35 ± 0.62 (−1.25 to 0.75) |
| UDVA (logMAR) | 0.20 ± 0.24 (−0.10 to 0.74) | 0.16 ± 0.11 (0.00 to 0.34) | 0.17 ± 0.20 (−0.10 to 0.54) | 0.10 ± 0.15 (−0.06 to 0.42) |
| UIVA (logMAR) | – | 0.33 ± 0.10 (0.20 to 0.40) | – | 0.43 ± 0.06 (0.30 to 0.48) |
| UNVA (logMAR) | – | 0.25 ± 0.10 (0.10 to 0.40) | – | 0.25 ± 0.13 (0.00 to 0.48) |
| CDVA (logMAR) | −0.02 ± 0.08 (−0.14 to 0.20) | 0.02 ± 0.08 (−0.10 to 0.12) | −0.02 ± 0.10 (−0.18 to 0.20) | −0.02 ± 0.09 (−0.18 to 0.10) |
Abbreviations: UIVA, unaided intermediate visual acuity; UNVA, unaided near visual acuity.
Refractive Outcomes Following IOL Exchange
| Multifocal to Monofocal (n = 21) | Multifocal to Multifocal (n = 16) | All (n = 37) | |
|---|---|---|---|
| Mean prediction error (D) ± SD (Range) | −0.57 ± 0.67 (−2.21 to 0.60) | −0.33 ± 0.59 (−1.53 to 0.72) | −0.46 ± 0.64 (−2.21 to 0.72) |
| Mean absolute error (D) ± SD (Range) | 0.70 ± 0.53 (0.04 to 2.21) | 0.56 ± 0.37 (0.10 to 1.53) | 0.64 ± 0.47 (0.04 to 2.21) |
Figure 2Lentis Mplus LU-814 MF30 IOL (image courtesy of Oculentis GmbH).