Literature DB >> 31298720

Comparison of Visual Outcomes and Patient Satisfaction After Bilateral Implantation of an EDOF IOL and a Mix-and-Match Approach.

Imane Tarib, Insa Kasier, Claudia Herbers, Philip Hagen, Detlev Breyer, Hakan Kaymak, Karsten Klabe, Rafaela Lucchesi, Swetlana Teisch, Vasilios F Diakonis, Ursula Hahn, Höhn Fabian, Florian T A Kretz.   

Abstract

PURPOSE: To evaluate visual outcomes at different distances (near, intermediate, and far), depth of focus, optical quality, quantitative dysphotopsia, and patient satisfaction in two groups.
METHODS: The extended depth of focus (EDOF) only group (n = 40 eyes) was implanted bilaterally with an EDOF intraocular lens (IOL) and the mixed group (n = 40 eyes) was implanted with the same EDOF IOL in the dominant eye and a trifocal IOL in the fellow eye. At the 3-month postoperative visit, refractive outcomes and monocular and binocular uncorrected (UDVA) and corrected (CDVA) distance visual acuities for far UDVA, CDVA, distance-corrected intermediate visual acuity (DCIVA) at 80 cm, uncorrected near visual acuity (UNVA), distance-corrected near visual acuity (DCNVA) at 40 cm, and binocular defocus curve were evaluated.
RESULTS: The mean spherical equivalent (SE) 3 months postoperatively was -0.16 ± 0.41 diopters (D) in the EDOF only group and -0.39 ± 0.63 D in the mixed group. In the EDOF only group, binocular visual acuities were: UDVA = -0.04 ± 0.07 logMAR (20/18); CDVA = -0.04 ± 0.06 logMAR (20/18); DCIVA (80 cm) = 0.07 ± 0.19 logMAR (20/23); DCNVA (40 cm) = 0.32 ± 0.15 logMAR (20/42); and UNVA (40 cm) = 0.24 ± 0.17 logMAR (20/35). In the mixed group, binocular visual acuities were: UDVA = 0.03 ± 0.09 logMAR (20/21) (P = .08); CDVA = -0.01 ± 0.07 logMAR (20/20) (P = .25); DCIVA (80 cm) = 0.24 ± 0.23 logMAR (20/35) (P = .08); DCNVA (40 cm) = 0.19 ± 0.07 logMAR (20/31) (P = .03); and UNVA (40 cm) = 0.18 ± 0.10 logMAR (20/30) (P = .37).
CONCLUSIONS: Effective restoration of visual acuity was demonstrated in both groups, with high levels of visual quality and patient satisfaction. Better results in near visual acuity were demonstrated in the mixed group. [J Refract Surg. 2019;35(7):408-416.]. Copyright 2019, SLACK Incorporated.

Entities:  

Year:  2019        PMID: 31298720     DOI: 10.3928/1081597X-20190417-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  12 in total

1.  Comparisons of visual outcomes between bilateral implantation and mix-and-match implantation of three types intraocular lenses.

Authors:  Shurui Ke; Wenjuan Wan; Can Li
Journal:  Int Ophthalmol       Date:  2022-09-20       Impact factor: 2.029

2.  Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses.

Authors:  Jung Wan Kim; Youngsub Eom; Wonkyung Park; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-05-28       Impact factor: 3.535

3.  Visual Acuity, Defocus Curve, Reading Speed and Patient Satisfaction with a Combined Extended Depth of Focus Intraocular Lens and Multifocal Intraocular Lens Modality.

Authors:  Helga P Sandoval; Richard Potvin; Kerry D Solomon
Journal:  Clin Ophthalmol       Date:  2020-09-15

4.  Evaluation of Visual and Subjective Outcomes with Mix-and-Match of Three One-Piece Tecnis Multifocal IOLs of Varying Add Powers.

Authors:  Steven J Dell
Journal:  Clin Ophthalmol       Date:  2020-09-29

5.  Visual Outcomes, Visual Quality and Patient Satisfaction: Comparing a Blended Bifocal Approach to Bilateral Extended Depth of Focus Intraocular Lens Implantation.

Authors:  Matthew D Hammond; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2019-11-27

Review 6.  Comparison of Patient Outcomes following Implantation of Trifocal and Extended Depth of Focus Intraocular Lenses: A Systematic Review and Meta-Analysis.

Authors:  Yining Guo; Yinhao Wang; Ran Hao; Xiaodan Jiang; Ziyuan Liu; Xuemin Li
Journal:  J Ophthalmol       Date:  2021-12-29       Impact factor: 1.909

7.  Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses.

Authors:  Richard N McNeely; Salissou Moutari; Stephen Stewart; Jonathan E Moore
Journal:  Int Ophthalmol       Date:  2021-09-21       Impact factor: 2.031

8.  The Effect of Spectacle-Induced Low Myopia in the Non-Dominant Eye on the Binocular Defocus Curve with a Non-Diffractive Extended Vision Intraocular Lens.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2021-08-24

9.  Patients' dissatisfaction with multifocal intraocular lenses managed by exchange with other multifocal lenses of different optical profiles.

Authors:  Olena Al-Shymali; Colm McAlinden; Jorge L Alio Del Barrio; Mario Canto-Cerdan; Jorge L Alio
Journal:  Eye Vis (Lond)       Date:  2022-03-01

10.  Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation.

Authors:  Leopoldo Spadea; Maria Ilaria Giannico; Martina Formisano; Ludovico Alisi
Journal:  Ther Clin Risk Manag       Date:  2021-07-16       Impact factor: 2.423

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.