Literature DB >> 32142039

Visual performance comparison of 2 extended depth-of-focus intraocular lenses.

Merita Schojai1, Tim Schultz, Corinna Jerke, Jörg Böcker, H Burkhard Dick.   

Abstract

PURPOSE: To compare the visual acuity and satisfaction outcomes of 2 different concepts of extended depth-of-focus intraocular lenses (EDOF IOLs).
SETTING: University Eye Hospital Bochum, Germany.
DESIGN: Prospective randomized comparative clinical trial.
METHODS: Patients undergoing cataract surgery with the implantation of 2 different concept EDOF IOLs. In the first group (IC-8 Group), a monofocal 1-piece Tecnis Z B00 IOL (Johnson & Johnson Vision Care, Inc.) was implanted in the dominant eye, and an IC-8 IOL (AcuFocus) was implanted in the nondominant eye. In the second group (Symfony Group), a Tecnis Symfony IOL (Johnson & Johnson Vision Care, Inc.) was implanted in both eyes. The target refraction of the dominant eye was emmetropia and slight myopia (mini-monovision, -0.75 diopters) in the nondominant eye. Visual and refractive outcomes and patient satisfaction rates were evaluated 3 months postoperatively.
RESULTS: This study comprised 76 eyes of 38 patients. No intraoperative or postoperative complications occurred in either group. Target refraction was reached in both groups without statistically significant differences. The uncorrected distance visual acuity (UDVA, photopic and mesopic light conditions) was excellent in both groups with statistically significantly better results in the IC-8 goup (logarithm of the minimum angle of resolution; IC-8 Group (0.1 ± 0.07 logarithm of the minimum angle of resolution [logMAR]; Symfony Group 0.07 ± 0.1 logMAR, P value .02 [photopic]; IC-8 group 0.12 ± 0.09 logMAR, Symfony group 0.22 ± 0.1 logMAR, P value < .01 [mesopic]). Binocular uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA) were also good in both groups without statistically significant differences (UIVA: IC-8 Group, 0.01 ± 0.07 logMAR, Symfony Group 0.01 ± 0.08 logMAR, P value .35; UNVA: IC-8 Group 0.14 ± 0.11, Symfony Group 0.09 ± 0.08, P value .14). Subjective satisfaction was high in both groups.
CONCLUSIONS: Both EDOF IOLs provided a very good UDVA with superior results in the IC-8 Group, and a good UIVA and UNVA under photopic light conditions. Subjective patient satisfaction was higher in the IC-8 Group.

Entities:  

Mesh:

Year:  2020        PMID: 32142039     DOI: 10.1097/j.jcrs.0000000000000068

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract Surgery: A Systematic Review and Bayesian Network Meta-analysis.

Authors:  Jeong-Yeon Cho; Yeo Kyoung Won; Jongyeop Park; Jin Hyun Nam; Ji-Yoon Hong; Serim Min; Nahyun Kim; Tae-Young Chung; Eui-Kyung Lee; Sun-Hong Kwon; Dong Hui Lim
Journal:  JAMA Ophthalmol       Date:  2022-09-22       Impact factor: 8.253

2.  Comparing Visual Acuity, Low Contrast Acuity and Contrast Sensitivity After Trifocal Toric and Extended Depth of Focus Toric Intraocular Lens Implantation.

Authors:  Kjell G Gundersen; Rick Potvin
Journal:  Clin Ophthalmol       Date:  2020-04-22

3.  Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study.

Authors:  María T Iradier; Verónica Cruz; Naty Gentile; Priscila Cedano; David P Piñero
Journal:  Clin Ophthalmol       Date:  2021-03-19

4.  Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs.

Authors:  Sri Ganesh; Sheetal Brar; Nikhil Rp; Dishitha Rathod
Journal:  Clin Ophthalmol       Date:  2021-10-21

5.  Clinical Outcomes and Quality of Vision Associated with Bilateral Implantation of a Wavefront Shaping Presbyopia Correcting Intraocular Lens.

Authors:  Kjell Gunnar Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2021-12-19

6.  The Effect of Spectacle-Induced Low Myopia in the Non-Dominant Eye on the Binocular Defocus Curve with a Non-Diffractive Extended Vision Intraocular Lens.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2021-08-24

7.  Presbyopia correction after previous Intracor treatment: Combined implantation of a small-aperture and a non-diffractive extended-depth-of-focus lens.

Authors:  Isabella D Baur; Gerd U Auffarth; Grzegorz Łabuz; Christian S Mayer; Ramin Khoramnia
Journal:  Am J Ophthalmol Case Rep       Date:  2022-02-04

8.  Patients' dissatisfaction with multifocal intraocular lenses managed by exchange with other multifocal lenses of different optical profiles.

Authors:  Olena Al-Shymali; Colm McAlinden; Jorge L Alio Del Barrio; Mario Canto-Cerdan; Jorge L Alio
Journal:  Eye Vis (Lond)       Date:  2022-03-01

Review 9.  Small Aperture IC-8 Extended-Depth-of-Focus Intraocular Lens in Cataract Surgery: A Systematic Review.

Authors:  José-María Sánchez-González; María Carmen Sánchez-González; Concepción De-Hita-Cantalejo; Antonio Ballesteros-Sánchez
Journal:  J Clin Med       Date:  2022-08-09       Impact factor: 4.964

10.  Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation.

Authors:  Leopoldo Spadea; Maria Ilaria Giannico; Martina Formisano; Ludovico Alisi
Journal:  Ther Clin Risk Manag       Date:  2021-07-16       Impact factor: 2.423

View more