Abstract
PURPOSE: The aim of this study was to compare straight and tapered implant designs in terms of marginal bone loss, the modified plaque index (mPI), and the modified bleeding index (mBI) for 5 years after functional loading.Entities:
Keywords: Alveolar bone loss; Bone remodeling; Dental implants
Year: 2021 PMID: 34965621 PMCID: PMC8718336 DOI: 10.5051/jpis.2101180059
Source DB: PubMed Journal: J Periodontal Implant Sci ISSN: 2093-2278 Impact factor: 2.614
Participants' characteristics and the position and type of the implants
| Subject | Age (yr) | Sex | Implant position | Implant type | Inter-implant distance (mm) |
|---|---|---|---|---|---|
| 1 | 73 | M | 36 | S | 2.7 |
| 37 | T | ||||
| 2 | 66 | F | 24 | S | 2.7 |
| 25 | T | ||||
| 3 | 75 | M | 25 | S | 3.5 |
| 26 | T | ||||
| 4 | 59 | M | 26 | S | 2.7 |
| 27 | T | ||||
| 5 | 66 | M | 25 | S | 5.2 |
| 26 | T | ||||
| 6 | 53 | F | 35 | T | 6.7 |
| 36 | S | ||||
| 7 | 64 | F | 16 | S | 4.7 |
| 17 | T | ||||
| 8 | 66 | M | 36 | S | 4.0 |
| 37 | T | ||||
| 9 | 65 | F | 16 | S | 3.4 |
| 17 | T | ||||
| 10 | 64 | F | 26 | S | 4.1 |
| 27 | T | ||||
| 11 | 64 | F | 15 | S | 3.0 |
| 16 | T | ||||
| 12 | 57 | M | 44 | S | 3.3 |
| 45 | T |
S: Astra Tech Osseospeed™ 4.0s implant, T: Astra Tech Osseospeed™ 5.0 implant.
Figure 1Schematic representation of the site and reference point measurements.
S: Astra Tech Osseospeed™ 4.0s implant, T: Astra Tech Osseospeed™ 5.0 implant, horizontal dotted line: reference point, horizontal solid line: measuring point, Ds1 and Ds2: distance from the reference point to the measuring point at S, Dt1 and Dt2: distance from the reference point to the measuring point at T.
Figure 2Periapical radiographs of implants. (A) 1 day after the first surgery; (B) the day of second surgery; (C) the day of prostheses delivery; (D) 1 year after functional loading; (E) 2 years after functional loading; (F) 3 years after functional loading; (G) 4 years after functional loading; (H) 5 years after functional loading.
MBL changes compared to baseline, mPI, and mBI at 1, 2, 3, 4 and 5 years after delivery of prostheses
| Year | Value | Type | Mean | SD | Min. | 1st Quartile | Median | 3rd Quartile | Max. | Wilcoxon signed rank test ( |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | MBL | S | 0.1 | 0.1 | 0.0 | 0.0 | 0.0 | 0.1 | 0.3 | 1.000 |
| T | 0.1 | 0.2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.5 | |||
| mPI | S | 0.4 | 0.4 | 0.0 | 0.0 | 0.5 | 0.5 | 1.0 | 0.734 | |
| T | 0.5 | 0.6 | 0.0 | 0.0 | 0.3 | 0.9 | 2.0 | |||
| mBI | S | 0.2 | 0.5 | 0.0 | 0.0 | 0.0 | 0.0 | 1.8 | 0.039 | |
| T | 0.3 | 0.6 | 0.0 | 0.0 | 0.2 | 0.3 | 2.0 | |||
| 2 | MBL | S | 0.1 | 0.1 | 0.0 | 0.0 | 0.0 | 0.2 | 0.3 | 0.705 |
| T | 0.1 | 0.2 | 0.0 | 0.0 | 0.0 | 0.1 | 0.5 | |||
| mPI | S | 0.3 | 0.4 | 0.0 | 0.0 | 0.2 | 0.5 | 1.3 | 0.180 | |
| T | 0.2 | 0.3 | 0.0 | 0.0 | 0.0 | 0.5 | 1.0 | |||
| mBI | S | 0.3 | 0.4 | 0.0 | 0.0 | 0.0 | 0.5 | 1.0 | 0.655 | |
| T | 0.2 | 0.4 | 0.0 | 0.0 | 0.0 | 0.5 | 1.0 | |||
| 3 | MBL | S | 0.1 | 0.1 | 0.0 | 0.0 | 0.0 | 0.2 | 0.3 | 0.461 |
| T | 0.1 | 0.3 | 0.0 | 0.0 | 0.0 | 0.2 | 0.7 | |||
| mPI | S | 0.3 | 0.5 | 0.0 | 0.0 | 0.0 | 0.3 | 1.8 | 0.854 | |
| T | 0.3 | 0.5 | 0.0 | 0.0 | 0.2 | 0.5 | 1.5 | |||
| mBI | S | 0.2 | 0.3 | 0.0 | 0.0 | 0.0 | 0.3 | 0.8 | 0.414 | |
| T | 0.3 | 0.4 | 0.0 | 0.0 | 0.0 | 0.5 | 1.3 | |||
| 4 | MBL | S | 0.1 | 0.2 | 0.0 | 0.0 | 0.1 | 0.2 | 0.6 | 0.684 |
| T | 0.1 | 0.3 | 0.0 | 0.0 | 0.0 | 0.2 | 0.7 | |||
| mPI | S | 0.1 | 0.2 | 0.0 | 0.0 | 0.0 | 0.2 | 0.5 | 0.317 | |
| T | 0.1 | 0.2 | 0.0 | 0.0 | 0.0 | 0.3 | 0.5 | |||
| mBI | S | 0.1 | 0.2 | 0.0 | 0.0 | 0.0 | 0.2 | 0.5 | 0.180 | |
| T | 0.2 | 0.3 | 0.0 | 0.0 | 0.0 | 0.5 | 0.8 | |||
| 5 | MBL | S | 0.2 | 0.4 | 0.0 | 0.0 | 0.1 | 0.3 | 1.3 | 0.833 |
| T | 0.2 | 0.3 | 0.0 | 0.0 | 0.0 | 0.4 | 0.7 | |||
| mPI | S | 0.3 | 0.3 | 0.0 | 0.0 | 0.3 | 0.5 | 1.0 | 0.414 | |
| T | 0.2 | 0.3 | 0.0 | 0.0 | 0.2 | 0.5 | 1.0 | |||
| mBI | S | 0.3 | 0.4 | 0.0 | 0.0 | 0.0 | 0.5 | 1.0 | 0.317 | |
| T | 0.2 | 0.3 | 0.0 | 0.0 | 0.0 | 0.3 | 1.0 |
Level of significance (P<0.05).
12 implants per type (S and T).
MBL: marginal bone level, mPI: modified plaque index, mBI: modified bleeding index, SD: standard deviation, S: Astra Tech Osseospeed ™ 4.0s implant, T: Astra Tech Osseospeed ™ 5.0 implant.
Post hoc Wilcoxon signed rank test of marginal bone loss by time (P value [adjusted level of significance])
| Type | Baseline | 1 year | 2 years | 3 years | 4 years | 5 years | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S | └0.034 (0.005)┘ | |||||||||||
| └0.157 (0.015)┘ | ||||||||||||
| └0.317 (0.025)┘ | ||||||||||||
| └0.102 (0.010)┘ | ||||||||||||
| └0.317 (0.025)┘ | ||||||||||||
| T | └0.180 (0.020)┘ | |||||||||||
| └0.180 (0.020)┘ | ||||||||||||
| └0.102 (0.010)┘ | ||||||||||||
| └1.000 (0.030)┘ | ||||||||||||
| └0.317 (0.025)┘ | ||||||||||||
The adjusted level of significance was calculated using the Benjamini-Hochberg adjustment based on a level of significance of <0.05.
S: Astra Tech Osseospeed ™ 4.0s implant, T: Astra Tech Osseospeed ™ 5.0 implant.
Marginal bone level changes between baseline and at 1, 2, 3, 4 and 5 years after prosthesis delivery according to jaw location
| Year | Position | Mean | SD | Min. | 1st Quartile | Median | 3rd Quartile | Max. | Mann-Whitney test ( |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Maxilla | 0.1 | 0.2 | 0.0 | 0.0 | 0.0 | 0.3 | 0.5 | 0.697 |
| Mandible | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 | 0.1 | ||
| 2 | Maxilla | 0.1 | 0.2 | 0.0 | 0.0 | 0.1 | 0.3 | 0.5 | 0.528 |
| Mandible | 0.0 | 0.1 | 0.0 | 0.0 | 0.0 | 0.1 | 0.2 | ||
| 3 | Maxilla | 0.2 | 0.2 | 0.0 | 0.0 | 0.1 | 0.3 | 0.7 | 0.452 |
| Mandible | 0.0 | 0.1 | 0.0 | 0.0 | 0.0 | 0.1 | 0.2 | ||
| 4 | Maxilla | 0.2 | 0.3 | 0.0 | 0.0 | 0.1 | 0.5 | 0.7 | 0.881 |
| Mandible | 0.1 | 0.1 | 0.0 | 0.0 | 0.0 | 0.2 | 0.3 | ||
| 5 | Maxilla | 0.3 | 0.3 | 0.0 | 0.0 | 0.1 | 0.6 | 0.7 | 1.000 |
| Mandible | 0.2 | 0.4 | 0.0 | 0.0 | 0.0 | 0.3 | 1.3 |
Level of significance (P<0.05).
16 implants in the maxilla and 8 implants in the mandible.
SD: standard deviation.
Pearson correlation coefficients between Inter-implant distance and marginal bone loss at the inter-implant side
| Year | S | T | ||
|---|---|---|---|---|
| Correlation coefficient |
| Correlation coefficient |
| |
| 1 | −0.2 | 0.500 | −0.3 | 0.351 |
| 2 | −0.1 | 0.711 | −0.3 | 0.351 |
| 3 | 0.0 | 0.987 | −0.3 | 0.351 |
| 4 | −0.1 | 0.684 | −0.3 | 0.351 |
| 5 | −0.1 | 0.684 | −0.1 | 0.649 |
Level of significance (P<0.05).
12 implants per type (S and T).
S: Astra Tech Osseospeed ™ 4.0s implant, T: Astra Tech Osseospeed ™ 5.0 implant.