Literature DB >> 9002835

Marginal bone levels at Brånemark system implants used for single tooth restoration. The influence of implant design and anatomical region.

C Malevez1, M Hermans, P Daelemans.   

Abstract

In this retrospective study of Brånemark system oral implants, 75 consecutive patients were treated with 84 implants for single-tooth replacement from 1988 to 1993. Two implants were lost and not replaced: the first one before the abutment connection, the latter during the first year in function. The cumulative failure rate reached 2.4% during the 5-year period. Seventy-one percent of the implants were located in the incisor/canine region of both jaws. Twenty-six per cent of the implants were inserted in special presurgical or surgical conditions. The mean annual bone loss as scored on radiograph, was 0.8 mm during the first year and 0.1 mm the following years. Different implant designs were used, a more pronounced bone loss was observed for the conical implant. The present data shows that the cumulative failure rate for single Brånemark implants and radiographic bone loss is similar to that found around implants used for the treatment of complete and partial edentulism.

Entities:  

Mesh:

Year:  1996        PMID: 9002835     DOI: 10.1034/j.1600-0501.1996.070210.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  A retrospective study of implant-abutment connections on crestal bone level.

Authors:  M-I Lin; Y-W Shen; H-L Huang; J-T Hsu; L-J Fuh
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

2.  Microstructured zirconia surfaces modulate osteogenic marker genes in human primary osteoblasts.

Authors:  Claudia Bergemann; Kathrin Duske; J Barbara Nebe; André Schöne; Ulrike Bulnheim; Hermann Seitz; Jens Fischer
Journal:  J Mater Sci Mater Med       Date:  2015-01-13       Impact factor: 3.896

3.  Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results.

Authors:  Han Park; Ik-Sang Moon; Chooryung Chung; Su-Jung Shin; Jong-Ki Huh; Jeong-Ho Yun; Dong-Won Lee
Journal:  J Periodontal Implant Sci       Date:  2021-12       Impact factor: 2.614

4.  Osseointegration of a novel dental implant in canine.

Authors:  Lingxiao Wang; Zhenhua Gao; Yucheng Su; Qian Liu; Yi Ge; Zhaochen Shan
Journal:  Sci Rep       Date:  2021-02-22       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.