Literature DB >> 20443797

Effect of conical configuration of fixture on the maintenance of marginal bone level: preliminary results at 1 year of function.

Jung-Joo Kim1, Dong-Won Lee, Chong-Kwan Kim, Kwang-Ho Park, Ik-Sang Moon.   

Abstract

OBJECTIVES: To evaluate and to compare the effect of the conical neck design on marginal bone loss around the fixtures, when both implants were provided with micro-threads to the top of the fixture.
MATERIALS AND METHODS: Two types of implant, one with a straight shape (S) and the other with a conical neck design (C) provided with a retentive element to the top of the fixture, were placed adjacent to each other in the partially edentulous areas of 12 patients. Bone loss around each implant was analyzed after 1 year of functional loading. The bone losses after loading were compared using Wilcoxon's signed-rank test.
RESULTS: The mean marginal bone losses (S, 0.05 + or - 0.09 mm; C, 0.07 + or - 0.14 mm) were not statistically significant between the two groups (P=0.578).
CONCLUSIONS: There was no significant difference between conical and straight neck implants in terms of marginal bone loss after 1 year of loading.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20443797     DOI: 10.1111/j.1600-0501.2009.01871.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Adult human gingival epithelial cells as a source for whole-tooth bioengineering.

Authors:  A Angelova Volponi; M Kawasaki; P T Sharpe
Journal:  J Dent Res       Date:  2013-03-04       Impact factor: 6.116

Review 2.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

3.  Evaluation of crestal bone resorption around cylindrical and conical implants following 6 months of loading: A randomized clinical trial.

Authors:  Naser Sargolzaie; Hamid Reza Arab; Marzieh Mohammadi Moghaddam
Journal:  Eur J Dent       Date:  2017 Jul-Sep

4.  Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results.

Authors:  Han Park; Ik-Sang Moon; Chooryung Chung; Su-Jung Shin; Jong-Ki Huh; Jeong-Ho Yun; Dong-Won Lee
Journal:  J Periodontal Implant Sci       Date:  2021-12       Impact factor: 2.614

5.  Does Oral Implant Design Affect Marginal Bone Loss? Results of a Parallel-Group Randomized Controlled Equivalence Trial.

Authors:  Benedikt C Spies; Maria Bateli; Ghada Ben Rahal; Marin Christmann; Kirstin Vach; Ralf-Joachim Kohal
Journal:  Biomed Res Int       Date:  2018-01-31       Impact factor: 3.411

6.  Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review.

Authors:  Saverio Cosola; Simone Marconcini; Michela Boccuzzi; Giovanni Battista Menchini Fabris; Ugo Covani; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Int J Environ Res Public Health       Date:  2020-09-22       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.