Literature DB >> 25327537

Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial.

Gerard Torroella-Saura1, Javier Mareque-Bueno, Josep Cabratosa-Termes, Federico Hernández-Alfaro, Eduard Ferrés-Padró, José Luis Calvo-Guirado.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the effect of two different designs, tapered vs cylindrical, on the primary stability of implants placed with an immediate loading protocol in edentulous mandibles to support fixed prostheses within occlusal contacts during the first 48 h.
MATERIAL AND METHODS: Tapered and cylindrical implants were placed in a split-mouth study using the same implant protocol in ten patients with edentulous jaws. A total of 20 tapered implants (test group) and 20 cylindrical implants (control group) were placed. All implants were loaded immediately with provisional fixed prostheses during the healing period before the final restoration. The implants were evaluated at the implant placement by analyzing the insertion torque values (ITVs) and the resonance frequency analysis (RFA) and after the healing period of three months, the success of those implants and the marginal bone loss were evaluated.
RESULTS: Two cylindrical implants were mobile within the same patient and no tapered implants failed, resulting in implant survival rates of 90% and 100%, respectively after three months. The ITVs were statistically significantly different (P = 0.0210) for the tapered implants than for the cylindrical implants. However, no statistically significant differences in RFA values were found (P = 0.6063) when comparing the implant designs and the primary stability measured with implant stability quotient (ISQ) values. The control group resulted in a mean bone loss after three months of 0.91 mm while the test group resulted 0.42 mm.
CONCLUSION: The tapered implant achieved greater primary stability values measured with ITVs and less marginal bone loss than the cylindrical implants.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  edentulous mandible; immediate loading; implant design; insertion torque; primary stability

Mesh:

Substances:

Year:  2014        PMID: 25327537     DOI: 10.1111/clr.12506

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Accuracy and primary stability of tapered or straight implants placed into fresh extraction socket using dynamic navigation: a randomized controlled clinical trial.

Authors:  Shi-Min Wei; Jun-Yu Shi; Shi-Chong Qiao; Xiao Zhang; Hong-Chang Lai; Xiao-Meng Zhang
Journal:  Clin Oral Investig       Date:  2021-11-19       Impact factor: 3.573

2.  Assessment of reporting quality in randomised controlled clinical trial abstracts of dental implantology published from 2014 to 2016.

Authors:  Stephanie Knippschild; Jeremias Loddenkemper; Sabrina Tulka; Christine Loddenkemper; Christine Baulig
Journal:  BMJ Open       Date:  2021-08-13       Impact factor: 2.692

3.  A Split-Mouth Design Comparison for Lateral and Crestal Sinus Lift Techniques with Dental Implants Placements: Short Communication.

Authors:  Saad Al-Almaie; Abdul Majeed Kavarodi; Ali Alorf; Saeed Alzahrani
Journal:  Open Dent J       Date:  2017-11-30

4.  Clinical evaluation of the stability of implants placed at different supracrestal levels.

Authors:  B Alper Gultekin; Ali Sirali; Pinar Gultekin; Selim Ersanli
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

5.  Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results.

Authors:  Han Park; Ik-Sang Moon; Chooryung Chung; Su-Jung Shin; Jong-Ki Huh; Jeong-Ho Yun; Dong-Won Lee
Journal:  J Periodontal Implant Sci       Date:  2021-12       Impact factor: 2.614

6.  Osseodensification effect on implants primary and secondary stability: Multicenter controlled clinical trial.

Authors:  Edmara T P Bergamo; Abbas Zahoui; Raúl Bravo Barrera; Salah Huwais; Paulo G Coelho; Edward Dwayne Karateew; Estevam A Bonfante
Journal:  Clin Implant Dent Relat Res       Date:  2021-05-27       Impact factor: 3.932

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.