Performance of conical abutment (Morse Taper) connection implants: a systematic review.

Christian M Schmitt1, Getulio Nogueira-Filho, Howard C Tenenbaum, Jim Yuan Lai, Carlos Brito, Hendrik Döring, Jörg Nonhoff.   

Abstract

In this systematic review, we aimed to compare conical versus nonconical implant-abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: "dental implant" AND "dental abutment" AND ("conical" OR "taper" OR "cone"). Names of the most common conical implant-abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty-two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta-analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant-abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  Morse Taper; dental abutment; dental implant; implant-abutment connection; systematic review

Mesh:

Year:  2013        PMID: 23533139     DOI: 10.1002/jbm.a.34709

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  32 in total

1.  3D X-ray microscopic analysys on a prosthetically loaded implant with platform-switching and conical connection: a case report.

Authors:  M DI Girolamo; L Baggi; P Pirelli; L Pappalardo; G Massei; F Iaculli; G Iezzi; A Piattelli; R Calcaterra
Journal:  Oral Implantol (Rome)       Date:  2017-11-30

Review 2.  Implant-abutment connections on single crowns: a systematic review.

Authors:  F M Ceruso; P Barnaba; S Mazzoleni; L Ottria; M Gargari; A Zuccon; G Bruno; A DI Fiore
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

3.  Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent.

Authors:  Pedro Ferrás Fernandes; Liliana Grenho; Maria Helena Fernandes; João Carlos Sampaio-Fernandes; Pedro Sousa Gomes
Journal:  Odontology       Date:  2021-08-27       Impact factor: 2.634

4.  A Finite Element Stress Analysis of a Concical Triangular Connection in Implants: A New Proposal.

Authors:  Romy Angeles Maslucan; John Alexis Dominguez
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

5.  Stress analysis and factor of safety in three dental implant systems by finite element analysis.

Authors:  E Menacho-Mendoza; R Cedamanos-Cuenca; A Díaz-Suyo
Journal:  Saudi Dent J       Date:  2022-08-27

6.  Single-tooth morse taper connection implant placed in grafted site of the anterior maxilla: clinical and radiographic evaluation.

Authors:  Francesco Guido Mangano; Piero Zecca; Fabrizia Luongo; Giovanna Iezzi; Carlo Mangano
Journal:  Case Rep Dent       Date:  2014-11-05

7.  In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection.

Authors:  Hooman Khorshidi; Saeed Raoofi; Afagh Moattari; Atoosa Bagheri; Mohammad Hassan Kalantari
Journal:  Int J Biomater       Date:  2016-05-03

Review 8.  Morse taper dental implants and platform switching: The new paradigm in oral implantology.

Authors:  José Paulo Macedo; Jorge Pereira; Brendan R Vahey; Bruno Henriques; Cesar A M Benfatti; Ricardo S Magini; José López-López; Júlio C M Souza
Journal:  Eur J Dent       Date:  2016 Jan-Mar

9.  Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis.

Authors:  Takashi Matsuoka; Tamaki Nakano; Satoshi Yamaguchi; Shinji Ono; Shota Watanabe; Takumi Sato; Hirofumi Yatani
Journal:  Materials (Basel)       Date:  2021-05-06       Impact factor: 3.623

10.  Impact of crestal and subcrestal implant placement in peri-implant bone: A prospective comparative study.

Authors:  Hilario Pellicer-Chover; María Peñarrocha-Diago; David Peñarrocha-Oltra; Sonia Gomar-Vercher; Rubén Agustín-Panadero; Miguel Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-01-01