Literature DB >> 21513475

Effect of interimplant distance (2 and 3 mm) on the height of interimplant bone crest: a histomorphometric evaluation.

Nicolas Elian1, Mitchell Bloom, Michel Dard, Sang-Choon Cho, Richard D Trushkowsky, Dennis Tarnow.   

Abstract

BACKGROUND: Implants restored according to a platform-switching concept (implant abutment interface with a reduced diameter relative to the implant platform diameter) present less crestal bone loss than implants restored with a standard protocol. When implants are placed adjacent to one another, this bone loss may combine through overlapping, thereby causing loss of the interproximal height of bone and papilla. The present study compares the effects of two interimplant distances (2 and 3 mm) on bone maintenance when bone-level implants with platform-switching are used.
METHODS: This study evaluates marginal bone level preservation and soft tissue quality around a bone-level implant after 2 months of healing in minipig mandibles. The primary objective is to evaluate histologically and histomorphometrically the affect that an implant design with a horizontally displaced implant-abutment junction has on the height of the crest of bone, between adjacent implants separated by two different distances.
RESULTS: Results show that the interproximal bone loss measured from the edge of the implant platform to the bone crest was not different for interimplant distances of 2 or 3 mm. The horizontal position of the bone relative to the microgap on platform level (horizontal component of crestal bone loss) was 0.31 ± 0.3 mm for the 2-mm interimplant distance and 0.57 ± 0.51 mm above the platform 8 weeks after implantation for the 3-mm interimplant distance.
CONCLUSIONS: This study shows that interimplant bone levels can be maintained at similar levels for 2- and 3-mm distances. The horizontally displaced implant-abutment junction provided for a more coronal position of the first point of bone-implant contact. The study reveals a smaller horizontal component at the crest of bone than has been reported for non-horizontally displaced implant-abutment junctions.

Entities:  

Mesh:

Year:  2011        PMID: 21513475     DOI: 10.1902/jop.2011.100661

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  8 in total

1.  Evaluation of Crestal Bone Loss Around Implants Placed at Equicrestal and Subcrestal Levels Before Loading: A Prospective Clinical Study.

Authors:  Balaji Nagarajan; Varsha Murthy; David Livingstone; Manohar Paul Surendra; Srinivasan Jayaraman
Journal:  J Clin Diagn Res       Date:  2015-12-01

2.  Case presentation of two patients using diagonal platform-switched double implants for maxillary single-first-molar replacement as the alternative of a single-tooth implant.

Authors:  Yasunori Hotta; Koji Ito; Shinichi Komatsu; Takashi Saito
Journal:  Int J Implant Dent       Date:  2015-11-12

3.  Multidisciplinary Approach in the Management of a Complex Case: Implant-Prosthetic Rehabilitation of a Periodontal Smoking Patient with Partial Edentulism, Malocclusion, and Aesthetic Diseases.

Authors:  Alessandro Lanza; Fabrizio Di Francesco; Gennaro De Marco; Fabio Scognamiglio; Valeria Aruta; Angelo Itro
Journal:  Case Rep Dent       Date:  2017-03-21

Review 4.  Survival and Success Rates of Different Shoulder Designs: A Systematic Review of the Literature.

Authors:  Marco Tallarico; Marco Caneva; Silvio Mario Meloni; Erta Xhanari; Yuki Omori; Luigi Canullo
Journal:  Int J Dent       Date:  2018-04-26

5.  Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results.

Authors:  Han Park; Ik-Sang Moon; Chooryung Chung; Su-Jung Shin; Jong-Ki Huh; Jeong-Ho Yun; Dong-Won Lee
Journal:  J Periodontal Implant Sci       Date:  2021-12       Impact factor: 2.614

6.  The minipig intraoral dental implant model: A systematic review and meta-analysis.

Authors:  Marta Liliana Musskopf; Amanda Finger Stadler; Ulf Me Wikesjö; Cristiano Susin
Journal:  PLoS One       Date:  2022-02-28       Impact factor: 3.240

7.  Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis.

Authors:  Takashi Matsuoka; Tamaki Nakano; Satoshi Yamaguchi; Shinji Ono; Shota Watanabe; Takumi Sato; Hirofumi Yatani
Journal:  Materials (Basel)       Date:  2021-05-06       Impact factor: 3.623

8.  Patient-centered rehabilitation of single, partial, and complete edentulism with cemented- or screw-retained fixed dental prosthesis: The First Osstem Advanced Dental Implant Research and Education Center Consensus Conference 2017.

Authors:  Marco Tallarico; Marco Caneva; Nicola Baldini; Fulvio Gatti; Marco Duvina; Mauro Billi; Gaetano Iannello; Giacomo Piacentini; Silvio Mario Meloni; Marco Cicciù
Journal:  Eur J Dent       Date:  2018 Oct-Dec
  8 in total