Literature DB >> 1290790

Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system.

M Quirynen1, I Naert, D van Steenberghe.   

Abstract

It has been documented that the long-term clinical outcome of the Brånemark system is very favourable. However, failures do occur before and after loading. This study examined the differences in marginal bone loss between standard and self-tapping fixtures and attempted to explain excessive marginal bone loss or loss of osseointegration during the first 3 years of loading. Marginal bone loss (scored on long cone radiographs) and fixture failure rate were compared for different fixture designs. For standard fixtures, in comparison with self-tapping fixtures, the failure rate was clearly higher before as well as after loading. However, for successful fixtures no difference in marginal bone loss was observed. For the conical fixtures an increased marginal bone loss around the smooth part was observed. The effect of fixture overload, marginal bone height and loss of osseointegration was examined in 69 patients with 1 and 15 patients with 2 fixed full prostheses, and in 9 patients with an overdenture in the upper jaw. Excessive marginal bone loss (more than 1 mm) after the first year of loading and/or fixture loss correlated well with the presence of overload due to a lack of anterior contact, the presence of parafunctional activity and osseointegrated full fixed prostheses in both jaws.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1290790     DOI: 10.1034/j.1600-0501.1992.030302.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  43 in total

1.  Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch.

Authors:  Bernd Koos; Arnim Godt; Christine Schille; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-11-17       Impact factor: 1.938

2.  Time-dependent analysis and representation of force distribution and occlusion contact in the masticatory cycle.

Authors:  Bernd Koos; Johanna Höller; Christine Schille; Arnim Godt
Journal:  J Orofac Orthop       Date:  2012-05-13       Impact factor: 1.938

3.  Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study.

Authors:  Sergio Alexandre Gehrke; Miriam Souza Dos Santos Vianna; Berenice Anina Dedavid
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

4.  A retrospective study of implant-abutment connections on crestal bone level.

Authors:  M-I Lin; Y-W Shen; H-L Huang; J-T Hsu; L-J Fuh
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

5.  Stress distribution in implant retained finger prosthesis: a finite element study.

Authors:  Pokpong Amornvit; Dinesh Rokaya; Konrawee Keawcharoen; Nimit Thongpulsawasdi
Journal:  J Clin Diagn Res       Date:  2013-12-15

6.  Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis.

Authors:  Kivanc Akca; Murat Cavit Cehreli
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

7.  Influence of implant number, length, and tilting degree on stress distribution in atrophic maxilla: a finite element study.

Authors:  Zeynep Gümrükçü; Yavuz Tolga Korkmaz
Journal:  Med Biol Eng Comput       Date:  2017-11-09       Impact factor: 2.602

8.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

9.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

Review 10.  Dental implant systems.

Authors:  Yoshiki Oshida; Elif B Tuna; Oya Aktören; Koray Gençay
Journal:  Int J Mol Sci       Date:  2010-04-12       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.