Literature DB >> 26744262

Peri-implant bone loss clinical and radiographic evaluation around rough neck and microthread implants: a 5-year study.

José Luis Calvo-Guirado1, Patricia J López-López1, Carlos Pérez-Albacete Martínez1, Fawad Javed2, José Manuel Granero-Marín1, José Eduardo Maté Sánchez de Val1, Maria Piedad Ramírez Fernández1.   

Abstract

OBJECTIVE: To evaluate marginal bone loss over 5 years around microthreaded implants placed in the maxillary anterior/esthetic zone and immediate restored with non-occlusal loading.
MATERIALS AND METHODS: Seventy-one implants (with microthreads up to the platform-rough surface body and neck, internal connection and platform switching) were placed in healed bone in the maxillary arches of 30 men and 23 women (mean age 37.85 ± 7.09 years, range 27-60). All subjects had at least 3 mm of soft tissue to allow the establishment of adequate biologic width and to reduce bone resorption. Each patient received a provisional restoration immediately after implant placement with slight occlusal contact. Mesial and distal bone height was evaluated using digital radiography on the day following implant placement (baseline) and after 1, 2, 3, 4 and 5 years. Primary stability was measured with resonance frequency analysis.
RESULTS: No implants failed, resulting in a cumulative survival rate of 100% after 3 years. Marginal bone loss from implant collar to bone crest measured at baseline (peri-implant bone defect at the fresh extraction socket) and after 5 years was 0.90 mm ± 0.26 mm. Mesial and distal site crestal bone loss ranged from 3.42 ± 1.2 mm at baseline to 3.51 ± 1.5 mm after 5 years and from 3.38 ± 0.9 mm at baseline to 3.49 ± 0.9 mm after 5 years, respectively (P = 0.086).
CONCLUSIONS: The results of this study showed limited implant crestal bone loss 0.90 mm ± 0.26 mm and 100% of implant survival rate at 5-year follow-up of immediate restored implants with rough surface neck and microthreads.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implants; immediate non-occlusal loading; marginal bone loss; microthread; rough surface neck

Mesh:

Substances:

Year:  2016        PMID: 26744262     DOI: 10.1111/clr.12775

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  7 in total

Review 1.  Evaluation of Implant Collar Surfaces for Marginal Bone Loss: A Systematic Review and Meta-Analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

2.  Evaluation of a New Dental Implant Cervical Design in Comparison with a Conventional Design in an Experimental American Foxhound Model.

Authors:  Maria Ángeles Pérez-Albacete Martínez; Carlos Pérez-Albacete Martínez; José Eduardo Maté Sánchez De Val; María Luisa Ramos Oltra; Manuel Fernández Domínguez; Jose Luis Calvo Guirado
Journal:  Materials (Basel)       Date:  2018-03-21       Impact factor: 3.623

3.  Esthetic aspects in implant-prosthetic rehabilitation.

Authors:  Norina Forna; Doriana Agop-Forna
Journal:  Med Pharm Rep       Date:  2019-12-15

4.  Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study.

Authors:  Sara Hussain Alhammadi; Girvan Burnside; Alexander Milosevic
Journal:  BMC Oral Health       Date:  2021-04-01       Impact factor: 2.757

5.  Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results.

Authors:  Han Park; Ik-Sang Moon; Chooryung Chung; Su-Jung Shin; Jong-Ki Huh; Jeong-Ho Yun; Dong-Won Lee
Journal:  J Periodontal Implant Sci       Date:  2021-12       Impact factor: 2.614

6.  Influence of Implant Neck Design on Peri-Implant Tissue Dimensions: A Comparative Study in Dogs.

Authors:  José Luis Calvo-Guirado; Raúl Jiménez-Soto; Carlos Pérez Albacete-Martínez; Manuel Fernández-Domínguez; Sérgio Alexandre Gehrke; José Eduardo Maté-Sánchez de Val
Journal:  Materials (Basel)       Date:  2018-10-17       Impact factor: 3.623

7.  A Retrospective Study on Insertion Torque and Implant Stability Quotient (ISQ) as Stability Parameters for Immediate Loading of Implants in Fresh Extraction Sockets.

Authors:  Giuseppe Bavetta; Giorgio Bavetta; Valentina Randazzo; Alessio Cavataio; Carlo Paderni; Vincenzo Grassia; Gianna Dipalma; Ciro Gargiulo Isacco; Antonio Scarano; Danila De Vito; Stefania Cantore; Andrea Ballini; Francesco Inchingolo
Journal:  Biomed Res Int       Date:  2019-11-03       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.