BACKGROUND: Stent manufacturers always record stent shortening data while they do not record stent elongation data. The aim of this study is to identify both stent shortening and elongation occurring after deployment in the coronary arteries and know their percentage.
RESULTS: The length of coronary stents was measured by intravascular ultrasound (IVUS) by (1) edge-to-edge (E-E) length, measured from the appearance of the first distal strut to the last proximal strut, and (2) area-to-area (A-A) length, measured from the first distal struts seen at more than one IVUS quadrant to the last proximal struts seen at more than one IVUS quadrant. Stent shortening was defined as both E-E and A-A lengths were shorter than the manufacturer box-stated length (shortened group). Stent elongation was defined as both E-E and A-A lengths were longer than the manufacturer box-stated length (elongated group), otherwise unchanged group. Consecutive 102 stents deployed in ischemic patients were included. Stent elongation was detected in 67.6% (69 stents), and shortening was detected in 15.7% (16 stents), while unchanged stents were detected in 16.7% (17 stents). Although the 3 groups had similar box-stated length and predicted foreshortened length, they had significantly different measurements by IVUS, p<0.001 for each comparison. Differences from box-stated length were 1.9±1.4mm, -1.4±0.4mm, and 0.4±0.3mm, respectively, p<0.001. The elongated group had significantly longer differences from the corresponding box-stated and predicted foreshortened lengths, while the shortened group had significantly shorter differences from the corresponding box-stated length and similar foreshortened length. By multinomial regression analysis, the plaque-media area and stent deployment pressure were the independent predictors of the stent length groups, p=0.015 and p=0.026, respectively.
CONCLUSIONS: Change in stent length is not only shortening-as mentioned in the manufacturer documents-but also stent elongation. Stent elongation is dominant, and the most important predictors of longitudinal stent changes are plaque-media area and stent deployment pressure.

Entities:  

Keywords:  IVUS; Stent elongation and shortening; Stent length

Year:  2021        PMID: 34002293     DOI: 10.1186/s43044-021-00170-9

Source DB:  PubMed          Journal:  Egypt Heart J        ISSN: 1110-2608


  25 in total

1.  Stent longitudinal integrity bench insights into a clinical problem.

Authors:  John A Ormiston; Bruce Webber; Mark W I Webster
Journal:  JACC Cardiovasc Interv       Date:  2011-11-30       Impact factor: 11.195

2.  Longitudinal stent deformation: a retrospective analysis of frequency and mechanisms.

Authors:  Paul D Williams; Mamas A Mamas; Kenneth P Morgan; Magdi El-Omar; Bernard Clarke; Anthony Bainbridge; Farzin Fath-Ordoubadi; Douglas G Fraser
Journal:  EuroIntervention       Date:  2012-06-20       Impact factor: 6.534

3.  Predictors and Long-Term Clinical Outcome of Longitudinal Stent Deformation: Insights From Pooled Analysis of Korean Multicenter Drug-Eluting Stent Cohort.

Authors:  Tae-Min Rhee; Kyung Woo Park; Joo Myung Lee; Michael S Lee; Ki-Hyun Jeon; Hyun-Jae Kang; Bon-Kwon Koo; Jay Young Rhew; Kwang Soo Cha; Jang-Ho Bae; Kyoo-Rok Han; Si-Hoon Park; Woo-Jung Park; Seung-Woon Rha; Seok-Kyu Oh; Hyuck Moon Kwon; Ki-Bae Seung; Taehoon Ahn; Sang-Hyun Kim; Hyo-Soo Kim
Journal:  Circ Cardiovasc Interv       Date:  2017-11       Impact factor: 6.546

4.  Impact of stent platform on longitudinal stent deformation: an in vivo frequency domain optical coherence tomography study.

Authors:  Ryotaro Yamada; Hiroyuki Okura; Teruyoshi Kume; Kenzo Fukuhara; Terumasa Koyama; Tomitaka Higa; Yoji Neishi; Kiyoshi Yoshida; Shiro Uemura
Journal:  Cardiovasc Interv Ther       Date:  2016-05-25

5.  Longitudinal deformation of contemporary coronary stents: an integrated analysis of clinical experience and observations from the bench.

Authors:  Mohamed Abdel-Wahab; Dmitriy S Sulimov; Guido Kassner; Volker Geist; Ralph Toelg; Gert Richardt
Journal:  J Interv Cardiol       Date:  2012-09-28       Impact factor: 2.279

6.  Intravascular ultrasonic assessment of stent diameters derived from manufacturer's compliance charts.

Authors:  Jose de Ribamar Costa; Gary S Mintz; Stéphane G Carlier; Ricardo A Costa; Kenichi Fujii; Koichi Sano; Masashi Kimura; Joanna Lui; Giora Weisz; Issam Moussa; George Dangas; Roxana Mehran; Alexandra J Lansky; Edward M Kreps; Michael Collins; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  Am J Cardiol       Date:  2005-07-01       Impact factor: 2.778

7.  Intravascular ultrasound assessment of drug-eluting stent expansion.

Authors:  Jose de Ribamar Costa; Gary S Mintz; Stéphane G Carlier; Kenichi Fujii; Koichi Sano; Masashi Kimura; Kaoru Tanaka; Ricardo A Costa; Joanna Lui; Yingbo Na; Celia Castellanos; Sinan Biro; Issam Moussa; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  Am Heart J       Date:  2007-02       Impact factor: 4.749

8.  Prevalence and anatomical features of acute longitudinal stent deformation: An intravascular ultrasound study.

Authors:  Shinji Inaba; Giora Weisz; Nobuaki Kobayashi; Shigeo Saito; Tomotaka Dohi; Liang Dong; Lin Wang; Joyce A Moran; LeRoy E Rabbani; Manish A Parikh; Martin B Leon; Jeffrey W Moses; Gary S Mintz; Akiko Maehara
Journal:  Catheter Cardiovasc Interv       Date:  2014-02-10       Impact factor: 2.692

9.  Longitudinal deformation of a third generation zotarolimus eluting stent: "The concertina returns!"

Authors:  Vasileios F Panoulas; Ozan M Demir; Neil Ruparelia; Iqbal Malik
Journal:  World J Cardiol       Date:  2017-01-26

10.  Coronary stent concertina in proximal left anterior descending artery: An unusual case.

Authors:  Shivanand Patil; Natraj Setty; Rangaraj Ramalingam; Jayashree Kharge; Cholenahally Nanjappa Manjunath
Journal:  Interv Med Appl Sci       Date:  2017-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.