Literature DB >> 17239693

Intravascular ultrasound assessment of drug-eluting stent expansion.

Jose de Ribamar Costa1, Gary S Mintz, Stéphane G Carlier, Kenichi Fujii, Koichi Sano, Masashi Kimura, Kaoru Tanaka, Ricardo A Costa, Joanna Lui, Yingbo Na, Celia Castellanos, Sinan Biro, Issam Moussa, Gregg W Stone, Jeffrey W Moses, Martin B Leon.   

Abstract

BACKGROUND: In the drug-eluting stent (DES) era, stent expansion remains an important predictor of restenosis and subacute thrombosis. Compliance charts are developed to predict final minimum stent diameter (MSD) and area (MSA). The objectives of the study were (1) to assess DES expansion by comparing intravascular ultrasound (IVUS)-measured MSD and MSA against the values predicted by compliance charts and (2) to compare each DES against its bare-metal stent (BMS) equivalent.
METHODS: We enrolled 200 patients with de novo coronary lesions treated with single, >2.5-mm Cypher (Cordis, Johnson & Johnson, Miami Lakes, FL) (sirolimus-eluting stent [SES], 133 patients) or Taxus (Boston Scientific, Natick, MA) (paclitaxel-eluting stent [PES], 67 patients) stent under IVUS guidance without another postdilation balloon. We used a comparison cohort of 65 equivalent BMS (Express 2 [Boston Scientific], 37 patients; Bx Velocity [Cordis, Johnson & Johnson], 28 patients) deployed under similar conditions.
RESULTS: The DES achieved only 75% +/- 10% of predicted MSD and 66% +/- 17% of predicted MSA; this was similar for SES and PES. Furthermore, 24% of SES and 28% of PES did not achieve a final MSA of 5 mm(2), a consistent predictor of DES failure. The SES achieved 75% +/- 10% of predicted MSA versus 75% +/- 9% for Bx Velocity (P = .9). The PES achieved 79.9% +/- 14% of predicted MSA versus 79% +/- 10% for Express 2 (P = .8). Lesion morphology, arc and length of calcium, stent diameter and length, and implantation pressures did not affect expansion.
CONCLUSIONS: Compliance charts fail to predict final MSD and MSA. A considerable percentage of DES does not achieve minimum standards of stent expansion. The SES and PES achieve similar expansion to their BMS platform, indicating that the polymer coating does not affect DES expansion in vivo. However, stent expansion cannot be predicted from preintervention IVUS lesion assessment.

Entities:  

Mesh:

Year:  2007        PMID: 17239693     DOI: 10.1016/j.ahj.2006.08.026

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  18 in total

1.  Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.

Authors:  Yoshitaka Muraoka; Shinjo Sonoda; Yuki Tsuda; Seiya Tanaka; Masahiro Okazaki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2010-12-23       Impact factor: 2.037

2.  New strategies in the treatment of coronary bifurcations.

Authors:  I Iakovou; N Foin; A Andreou; N Viceconte; C Di Mario
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

Review 3.  Assessment of drug-eluting stents and bioresorbable stents by grayscale IVUS and IVUS-based imaging modalities.

Authors:  Salvatore Brugaletta; Jose Ribamar Costa; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

4.  Compliance charts to guide non-complex small artery stenting: validation by quantitative coronary angiography.

Authors:  Yohan Chacko; J Kimberly Haladyn; Debbie M Smith; Richard Lim
Journal:  Heart Asia       Date:  2013-05-31

Review 5.  Mechanoresponsive materials for drug delivery: Harnessing forces for controlled release.

Authors:  Julia Wang; Jonah A Kaplan; Yolonda L Colson; Mark W Grinstaff
Journal:  Adv Drug Deliv Rev       Date:  2016-11-14       Impact factor: 15.470

6.  Healing score of the Xinsorb scaffold in the treatment of de novo lesions: 6-month imaging outcomes.

Authors:  Xucheng Lv; Li Shen; Yizhe Wu; Lei Ge; Jiahui Chen; Jiasheng Yin; Rui Wang; Meng Ji; Bin Hong; Junbo Ge
Journal:  Int J Cardiovasc Imaging       Date:  2018-02-28       Impact factor: 2.357

7.  Impact of Intravascular Ultrasound in Clinical Practice.

Authors:  Andres Vasquez; Neville Mistry; Jasvindar Singh
Journal:  Interv Cardiol       Date:  2014-08

8.  Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons.

Authors:  Ashok Seth; Sajal Gupta; Vivudh Pratap Singh; Vijay Kumar
Journal:  Interv Cardiol       Date:  2017-09

Review 9.  Restenosis after PCI. Part 1: pathophysiology and risk factors.

Authors:  J Wouter Jukema; Jeffrey J W Verschuren; Tarek A N Ahmed; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-09-13       Impact factor: 32.419

10.  Longitudinal stent elongation or shortening after deployment in the coronary arteries: which is dominant?

Authors:  Magdy Algowhary; Mohammed Aboel-Kassem F Abdelmegid
Journal:  Egypt Heart J       Date:  2021-05-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.