Impact of stent platform on longitudinal stent deformation: an in vivo frequency domain optical coherence tomography study.

Ryotaro Yamada1, Hiroyuki Okura2, Teruyoshi Kume2, Kenzo Fukuhara2, Terumasa Koyama2, Tomitaka Higa2, Yoji Neishi2, Kiyoshi Yoshida3, Shiro Uemura2.   

Abstract

Recently, longitudinal coronary stent deformation has been highlighted as a possible cause of drug-eluting stent failure. Although bench tests and in vivo studies have demonstrated difference in longitudinal stent strength among the stents with different platforms, its clinical impact is still unknown. Furthermore, it is unknown if modified stent platform favorably affect the incidence of stent deformation. The aim of this study was to investigate the longitudinal deformation of the everolimus-eluting stents (EES) with different stent platforms by using frequency domain optical coherence tomography (FD-OCT). Seventy-eight lesions treated with EES (Xience Prime: n = 26, Promus element: n = 29, Promus premier: n = 23) were studied. After successful stent implantation, FD-OCT was performed and stent length was measured using three-dimensional reconstruction of the images in vivo. Percent longitudinal stent shortening (%SS) was defined as the in vivo stent length divided by nominal stent length. Longitudinal stent deformation was defined as  %SS > 10 %. Patients' and procedural characteristics were similar among 3 EESs. There was no difference in mean  %SS between Xience Prime, Promus Element and Promus Premier (1.0 ± 5.8, 2.9 ± 6.7 and 0.8 ± 3.7 %, p = 0.322). Incidence of the longitudinal stent deformation was significantly higher in Promus Element than the other stents (0, 13.8 and 0 %, p = 0.028). Incidence of longitudinal stent deformation was different between EESs with different stent platforms. Stent material, stent design and/or stent delivery balloon may affect longitudinal stent deformation.

Entities:  

Keywords:  Deformation; Drug-eluting stent fracture; Optical coherence tomography

Mesh:

Substances:

Year:  2016        PMID: 27226007     DOI: 10.1007/s12928-016-0403-3

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  3 in total

1.  Longitudinal stent elongation or shortening after deployment in the coronary arteries: which is dominant?

Authors:  Magdy Algowhary; Mohammed Aboel-Kassem F Abdelmegid
Journal:  Egypt Heart J       Date:  2021-05-17

2.  Comparison of diagnostic performance in assessing the rewiring position into a jailed side branch between online 3D reconstruction systems version 1.1 and 1.2 derived from optical frequency domain imaging.

Authors:  Tatsuhiro Fujimura; Takayuki Okamura; Kazuki Furuya; Yosuke Miyazaki; Hitoshi Takenaka; Hiroki Tateishi; Tetsuro Oda; Mamoru Mochizuki; Hitoshi Uchinoumi; Takashi Nishimura; Jutaro Yamada; Masafumi Yano
Journal:  Cardiovasc Interv Ther       Date:  2019-11-09

3.  Evaluation of Mechanical Performances of Stents with 38 mm Length in Long Lesion.

Authors:  Xiaoting Yue; Jiacheng Guo; Jianchao Zhang; Chang Cao; Zenglei Zhang; Deliang Shen; Junnan Tang; Jinying Zhang
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.