Literature DB >> 33304618

Development of a scanner-specific simulation framework for photon-counting computed tomography.

Ehsan Abadi1, Brian Harrawood1, Jayasai R Rajagopal1, Shobhit Sharma1, Anuj Kapadia1, William Paul Segars1, Karl Stierstorfer1, Martin Sedlmair1, Elizabeth Jones1, Ehsan Samei1.   

Abstract

The aim of this study was to develop and validate a simulation platform that generates photon-counting CT images of voxelized phantoms with detailed modeling of manufacturer-specific components including the geometry and physics of the x-ray source, source filtrations, anti-scatter grids, and photon-counting detectors. The simulator generates projection images accounting for both primary and scattered photons using a computational phantom, scanner configuration, and imaging settings. Beam hardening artifacts are corrected using a spectrum and threshold dependent water correction algorithm. Physical and computational versions of a clinical phantom (ACR) were used for validation purposes. The physical phantom was imaged using a research prototype photon-counting CT (Siemens Healthcare) with standard (macro) mode, at four dose levels and with two energy thresholds. The computational phantom was imaged with the developed simulator with the same parameters and settings used in the actual acquisition. Images from both the real and simulated acquisitions were reconstructed using a reconstruction software (FreeCT). Primary image quality metrics such as noise magnitude, noise ratio, noise correlation coefficients, noise power spectrum, CT number, in-plane modulation transfer function, and slice sensitivity profiles were extracted from both real and simulated data and compared. The simulator was further evaluated for imaging contrast materials (bismuth, iodine, and gadolinium) at three concentration levels and six energy thresholds. Qualitatively, the simulated images showed similar appearance to the real ones. Quantitatively, the average relative error in image quality measurements were all less than 4% across all the measurements. The developed simulator will enable systematic optimization and evaluation of the emerging photon-counting computed tomography technology.

Entities:  

Keywords:  computational phantoms; computed tomography; photon-counting; photon-counting computed tomography; simulation; virtual clinical trial

Year:  2019        PMID: 33304618      PMCID: PMC7725233          DOI: 10.1088/2057-1976/ab37e9

Source DB:  PubMed          Journal:  Biomed Phys Eng Express        ISSN: 2057-1976


  25 in total

1.  Optimized generation of high resolution breast anthropomorphic software phantoms.

Authors:  David D Pokrajac; Andrew D A Maidment; Predrag R Bakic
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2005-12-01       Impact factor: 3.609

3.  DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography.

Authors:  Ehsan Abadi; Brian Harrawood; Shobhit Sharma; Anuj Kapadia; William P Segars; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2018-12-12       Impact factor: 10.048

4.  Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit.

Authors:  Andreu Badal; Aldo Badano
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

5.  Spatio-energetic cross-talk in photon counting detectors: N × N binning and sub-pixel masking.

Authors:  Katsuyuki Taguchi; Karl Stierstorfer; Christoph Polster; Okkyun Lee; Steffen Kappler
Journal:  Med Phys       Date:  2018-09-27       Impact factor: 4.071

6.  To bin or not to bin? The effect of CT system limiting resolution on noise and detectability.

Authors:  Jongduk Baek; Angel R Pineda; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2013-02-11       Impact factor: 3.609

7.  Spatio-energetic cross-talk in photon counting detectors: Numerical detector model (PcTK) and workflow for CT image quality assessment.

Authors:  Katsuyuki Taguchi; Karl Stierstorfer; Christoph Polster; Okkyun Lee; Steffen Kappler
Journal:  Med Phys       Date:  2018-04-15       Impact factor: 4.071

8.  Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data.

Authors:  Nooshin Kiarashi; Adam C Nolte; Gregory M Sturgeon; William P Segars; Sujata V Ghate; Loren W Nolte; Ehsan Samei; Joseph Y Lo
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

9.  Strategies for scatter correction in dual source CT.

Authors:  M Petersilka; K Stierstorfer; H Bruder; T Flohr
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

10.  Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment.

Authors:  A Pourmorteza; R Symons; D S Reich; M Bagheri; T E Cork; S Kappler; S Ulzheimer; D A Bluemke
Journal:  AJNR Am J Neuroradiol       Date:  2017-10-05       Impact factor: 3.825

View more
  4 in total

1.  A scanner-specific framework for simulating CT images with tube current modulation.

Authors:  Giavanna Jadick; Ehsan Abadi; Brian Harrawood; Shobhit Sharma; W Paul Segars; Ehsan Samei
Journal:  Phys Med Biol       Date:  2021-09-13       Impact factor: 3.609

2.  Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom.

Authors:  Sachin S Shankar; Giavanna L Jadick; Eric A Hoffman; Jarron Atha; Jessica C Sieren; Ehsan Samei; Ehsan Abadi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

3.  Photon-counting CT versus conventional CT for COPD quantifications: intra-scanner optimization and inter-scanner assessments using virtual imaging trials.

Authors:  Saman Sotoudeh-Paima; W Paul Segars; Ehsan Samei; Ehsan Abadi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

4.  Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT.

Authors:  Ehsan Abadi; Cindy McCabe; Brian Harrawood; Saman Sotoudeh-Paima; W Paul Segars; Ehsan Samei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.