Literature DB >> 23399724

To bin or not to bin? The effect of CT system limiting resolution on noise and detectability.

Jongduk Baek1, Angel R Pineda, Norbert J Pelc.   

Abstract

We examine the noise advantages of having a computed tomography (CT) detector whose spatial resolution is significantly better (e.g. a factor of 2) than needed for a desired resolution in the reconstructed images. The effective resolution of detectors in x-ray CT is sometimes degraded by binning cells because the small cell size and fine sampling are not needed to achieve the desired resolution (e.g. with flat panel detectors). We studied the effect of the binning process on the noise in the reconstructed images and found that while the images in the absence of noise can be made identical for the native and the binned system, for the same system MTF in the presence of noise, the binned system always results in noisier reconstructed images. The effect of the increased noise in the reconstructed images on lesion detection is scale (frequency content) dependent with a larger difference between the high resolution and binned systems for imaging fine structure (small objects). We show simulated images reconstructed with both systems for representative objects and quantify the impact of the noise on the detection of the lesions based on mathematical observers. Through both subjective assessment of the reconstructed images and the quantification using mathematical observers, we show that for a CT system where the photon noise is dominant, higher resolution in the detectors leads to better noise performance in the reconstructed images at any resolution.

Mesh:

Year:  2013        PMID: 23399724     DOI: 10.1088/0031-9155/58/5/1433

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study.

Authors:  Mats Persson; Adam Wang; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2020-07-17

Review 2.  Task-based measures of image quality and their relation to radiation dose and patient risk.

Authors:  Harrison H Barrett; Kyle J Myers; Christoph Hoeschen; Matthew A Kupinski; Mark P Little
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

3.  150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images.

Authors:  Shuai Leng; Kishore Rajendran; Hao Gong; Wei Zhou; Ahmed F Halaweish; Andre Henning; Steffen Kappler; Matthias Baer; Joel G Fletcher; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2018-11       Impact factor: 6.016

4.  Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Authors:  Joakim da Silva; Fredrik Grönberg; Björn Cederström; Mats Persson; Martin Sjölin; Zlatan Alagic; Robert Bujila; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-15

5.  Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

Authors:  Hyo-Min Cho; William C Barber; Huanjun Ding; Jan S Iwanczyk; Sabee Molloi
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  Development of a scanner-specific simulation framework for photon-counting computed tomography.

Authors:  Ehsan Abadi; Brian Harrawood; Jayasai R Rajagopal; Shobhit Sharma; Anuj Kapadia; William Paul Segars; Karl Stierstorfer; Martin Sedlmair; Elizabeth Jones; Ehsan Samei
Journal:  Biomed Phys Eng Express       Date:  2019-08-09

7.  Low-dose lung cancer screening with photon-counting CT: a feasibility study.

Authors:  Rolf Symons; Tyler E Cork; Pooyan Sahbaee; Matthew K Fuld; Steffen Kappler; Les R Folio; David A Bluemke; Amir Pourmorteza
Journal:  Phys Med Biol       Date:  2016-12-17       Impact factor: 3.609

8.  Photon Counting CT: Clinical Applications and Future Developments.

Authors:  Scott S Hsieh; Shuai Leng; Kishore Rajendran; Shengzhen Tao; Cynthia H McCollough
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-08-28

Review 9.  Recent and future directions in CT imaging.

Authors:  Norbert J Pelc
Journal:  Ann Biomed Eng       Date:  2014-01-17       Impact factor: 3.934

Review 10.  Photon-counting detectors in computed tomography: from quantum physics to clinical practice.

Authors:  E Wehrse; L Klein; L T Rotkopf; W L Wagner; M Uhrig; C P Heußel; C H Ziener; S Delorme; S Heinze; M Kachelrieß; H-P Schlemmer; S Sawall
Journal:  Radiologe       Date:  2021-02-17       Impact factor: 0.635

View more