Literature DB >> 29537627

Spatio-energetic cross-talk in photon counting detectors: Numerical detector model (PcTK) and workflow for CT image quality assessment.

Katsuyuki Taguchi1, Karl Stierstorfer2, Christoph Polster2,3, Okkyun Lee1, Steffen Kappler2.   

Abstract

PURPOSE: The interpixel cross-talk of energy-sensitive photon counting x-ray detectors (PCDs) has been studied and an analytical model (version 2.1) has been developed for double-counting between neighboring pixels due to charge sharing and K-shell fluorescence x-ray emission followed by its reabsorption (Taguchi K, et al., Medical Physics 2016;43(12):6386-6404). While the model version 2.1 simulated the spectral degradation well, it had the following problems that has been found to be significant recently: (1) The spectrum is inaccurate with smaller pixel sizes; (2) the charge cloud size must be smaller than the pixel size; (3) the model underestimates the spectrum/counts for 10-40 keV; and (4) the model version 2.1 cannot handlen-tuple-counting withn > 2 (i.e., triple-counting or higher). These problems are inherent to the design of the model version 2.1; therefore, we developed a new model and addressed these problems in this study.
METHODS: We propose a new PCD cross-talk model (version 3.2; Pc TK for "photon counting toolkit") that is based on a completely different design concept from the previous version. It uses a numerical approach and starts with a 2-D model of charge sharing (as opposed to an analytical approach and a 1-D model with version 2.1) and addresses all of the four problems. The model takes the following factors into account: (1) shift-variant electron density of the charge cloud (Gaussian-distributed), (2) detection efficiency, (3) interactions between photons and PCDs via photoelectric effect, and (4) electronic noise. Correlated noisy PCD data can be generated using either a multivariate normal random number generator or a Poisson random number generator. The effect of the two parameters, the effective charge cloud diameter (d0 ) and pixel size (dpix ), was studied and results were compared with Monte Carlo simulations and the previous model version 2.1. Finally, a script for the workflow for CT image quality assessment has been developed, which started with a few material density images, generated material-specific sinogram (line integrals) data, noisy PCD data with spectral distortion using the model version 3.2, and reconstructed PCD- CT images for four energy windows.
RESULTS: The model version 3.2 addressed all of the four problems listed above. The spectra withdpix  = 56-113 μm agreed with that of Medipix3 detector withdpix  = 55-110 μm without charge summing mode qualitatively. The counts for 10-40 keV were larger than the previous model (version 2.1) and agreed with MC simulations very well (root-mean-square difference values with model version 3.2 were decreased to 16%-67% of the values with version 2.1). There were many non-zero off-diagonal elements withn-tuple-counting withn > 2 in the normalized covariance matrix of 3 × 3 neighboring pixels. Reconstructed images showed biases and artifacts attributed to the spectral distortion due to the charge sharing and fluorescence x rays.
CONCLUSION: We have developed a new PCD model for spatio-energetic cross-talk and correlation between PCD pixels. The workflow demonstrated the utility of the model for general or task-specific image quality assessments for the PCD- CT.Note: The program (Pc TK) and the workflow scripts have been made available to academic researchers. Interested readers should visit the website (pctk.jhu.edu) or contact the corresponding author.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  computed tomography; cross-talk; double-counting; photon counting; spectral distortion; spectral response

Mesh:

Year:  2018        PMID: 29537627     DOI: 10.1002/mp.12863

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study.

Authors:  Mats Persson; Adam Wang; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2020-07-17

2.  Low-dose photon counting CT reconstruction bias reduction with multi-energy alternating minimization algorithm.

Authors:  Jingwei Lu; Shuangyue Zhang; David G Politte; Joseph A O'Sullivan
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-05-28

3.  Development of a scanner-specific simulation framework for photon-counting computed tomography.

Authors:  Ehsan Abadi; Brian Harrawood; Jayasai R Rajagopal; Shobhit Sharma; Anuj Kapadia; William Paul Segars; Karl Stierstorfer; Martin Sedlmair; Elizabeth Jones; Ehsan Samei
Journal:  Biomed Phys Eng Express       Date:  2019-08-09

4.  Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.

Authors:  Xu Ji; Kevin Treb; Ke Li
Journal:  Phys Med Biol       Date:  2021-04-14       Impact factor: 3.609

5.  Ultra-Low-Dose Spectral CT Based on a Multi-level Wavelet Convolutional Neural Network.

Authors:  Minjae Lee; Hyemi Kim; Hyo-Min Cho; Hee-Joung Kim
Journal:  J Digit Imaging       Date:  2021-09-29       Impact factor: 4.056

6.  Photon Counting CT: Clinical Applications and Future Developments.

Authors:  Scott S Hsieh; Shuai Leng; Kishore Rajendran; Shengzhen Tao; Cynthia H McCollough
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-08-28

7.  Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.

Authors:  Adam S Wang; Norbert J Pelc
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-07-07

8.  Assessment of Multienergy Interpixel Coincidence Counters (MEICC) for Charge Sharing Correction or Compensation for Photon Counting Detectors With Boxcar Signals.

Authors:  Katsuyuki Taguchi
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-06-17

Review 9.  Advances in micro-CT imaging of small animals.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2021-07-17       Impact factor: 3.119

10.  Photon-counting cine-cardiac CT in the mouse.

Authors:  Darin P Clark; Matthew Holbrook; Chang-Lung Lee; Cristian T Badea
Journal:  PLoS One       Date:  2019-09-19       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.