Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT.

Ehsan Abadi1, Cindy McCabe1, Brian Harrawood1, Saman Sotoudeh-Paima1, W Paul Segars1, Ehsan Samei1.   

Abstract

The purpose of this study was to develop a virtual imaging framework that simulates a new photon-counting CT (PCCT) system (NAEOTOM Alpha, Siemens). The PCCT simulator was built upon the DukeSim platform, which generates projection images of computational phantoms given the geometry and physics of the scanner and imaging parameters. DukeSim was adapted to account for the geometry of the PCCT prototype. To model the photon-counting detection process, we utilized a Monte Carlo-based detector model with the known properties of the detectors. We validated the simulation platform against experimental measurements. The images were acquired at four dose levels (CTDIvol of 1.5, 3.0, 6.0, and 12.0 mGy) and reconstructed with three kernels (Br36, Br40, Br48). The experimental acquisitions were replicated using our developed simulation platform. The real and simulated images were quantitatively compared in terms of image quality metrics (HU values, noise magnitude, noise power spectrum, and modulation transfer function). The clinical utility of our framework was demonstrated by conducting two clinical applications (COPD quantifications and lung nodule radiomics). The phantoms with relevant pathologies were imaged with DukeSim modeling the PCCT systems. Different imaging parameters (e.g., dose, reconstruction techniques, pixel size, and slice thickness) were altered to investigate their effects on task-based quantifications. We successfully implemented the acquisition and physics attributes of the PCCT prototype into the DukeSim platform. The discrepancy between the real and simulated data was on average about 2 HU in terms of noise magnitude, 0.002 mm-1 in terms of noise power spectrum peak frequency and 0.005 mm-1 in terms of the frequency at 50% MTF. Analysis suggested that lung lesion radiomics to be more accurate with reduced pixel size and slice thickness. For COPD quantifications, higher doses, thinner slices, and softer kernels yielded more accurate quantification of density-based biomarkers. Our developed virtual imaging platform enables systematic comparison of new PCCT technologies as well as optimization of the imaging parameters for specific clinical tasks.

Entities:  

Keywords:  COPD; CT Quantifications; CT simulator; Computed Tomography; DukeSim; Photon-counting CT; Radiomics; Virtual clinical trial; Virtual imaging trials; XCAT

Year:  2022        PMID: 35611365      PMCID: PMC9125732          DOI: 10.1117/12.2612079

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  7 in total

1.  DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography.

Authors:  Ehsan Abadi; Brian Harrawood; Shobhit Sharma; Anuj Kapadia; William P Segars; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2018-12-12       Impact factor: 10.048

2.  A GPU-accelerated framework for rapid estimation of scanner-specific scatter in CT for virtual imaging trials.

Authors:  Shobhit Sharma; Ehsan Abadi; Anuj Kapadia; W Paul Segars; Ehsan Samei
Journal:  Phys Med Biol       Date:  2021-03-23       Impact factor: 3.609

Review 3.  Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.

Authors:  W Paul Segars; B M W Tsui; George S K Fung; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2017-08-10       Impact factor: 10.048

4.  Modeling Lung Architecture in the XCAT Series of Phantoms: Physiologically Based Airways, Arteries and Veins.

Authors:  Ehsan Abadi; William P Segars; Gregory M Sturgeon; Justus E Roos; Carl E Ravin; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2018-03       Impact factor: 10.048

5.  Development of a scanner-specific simulation framework for photon-counting computed tomography.

Authors:  Ehsan Abadi; Brian Harrawood; Jayasai R Rajagopal; Shobhit Sharma; Anuj Kapadia; William Paul Segars; Karl Stierstorfer; Martin Sedlmair; Elizabeth Jones; Ehsan Samei
Journal:  Biomed Phys Eng Express       Date:  2019-08-09

6.  Photon-counting CT versus conventional CT for COPD quantifications: intra-scanner optimization and inter-scanner assessments using virtual imaging trials.

Authors:  Saman Sotoudeh-Paima; W Paul Segars; Ehsan Samei; Ehsan Abadi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

Review 7.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.