Literature DB >> 12375253

Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty.

Nicholas J Phillips1, Ian Stockley, J Mark Wilkinson.   

Abstract

We aimed to determine whether the precision and sensitivity of migration measurements after total hip arthroplasty (THA) using direct plain radiographic techniques could be made comparable to those of digital methods (EBRA-Digital; University of Innsbruck, Innsbruck, Austria) by careful control of radiographic technique and use of modern measuring tools. Precision was examined by analysis of consecutive radiographs taken after repositioning in 20 patients after hybrid THA. The precision (95% confidence interval) of measurements for cup migration using direct methods was +/-1.11 to 3.07 mm (x-axis) and +/-1.28 to 1.92 mm (y-axis). The precision of EBRA for cup measurements was +/-1.00 mm (x-axis) and +/-0.82 mm (y-axis). The precision of stem y-axis migration measurements was +/-1.12 to 6.91 mm using direct methods and +/-0.80 mm using EBRA. Migration of the stem (1.53 mm subsidence; P<.01) and the cup (0.53 mm cranial migration, P<.05) was detected using EBRA in 10 patients followed for 6 months after hybrid THA, but significant migration was not detectable using the most precise of the direct methods. Careful measures to standardize plain radiographs improve precision of direct radiographic measurements; however, their long-term sensitivity remains inferior to methods that employ quality control and measurement algorithms to measure migration from digitized radiographs. Copyright 2002, Elsevier Science (USA)

Entities:  

Mesh:

Year:  2002        PMID: 12375253     DOI: 10.1054/arth.2002.34529

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  21 in total

1.  Comment on: Markmiller M, Weiss T, Kreuz P, Rüter A, Konrad G. Partial weightbearing is not necessary after cementless total hip arthroplasty. Int Orthop. 2011 Aug;35(8):1139-43.

Authors:  Mandeep Dhillon; Vikas Bachhal; Devendra Chouhan; Vishal Kumar
Journal:  Int Orthop       Date:  2011-12-03       Impact factor: 3.075

2.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

3.  Migration of the Duraloc cup after 5 years.

Authors:  Christoph Stihsen; Christof Pabinger; Roman Radl; Peter Rehak; Reinhard Windhager
Journal:  Int Orthop       Date:  2007-07-03       Impact factor: 3.075

4.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

5.  Preoperative digital planning versus postoperative outcomes in total hip arthroplasty using a calcar-guided short stem: frequent valgization can be avoided.

Authors:  Karl Philipp Kutzner; Joachim Pfeil; Mark Predrag Kovacevic
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-08

6.  Biomechanical assays for the study of the effects of hip prostheses: application to the reconstruction of bone defects with femoral allografts.

Authors:  Alberto Francés; Rafael Claramunt; Juan-Luis Cebrian; Fernando Marco; Yaiza Lópiz; Ramon Muiña Rullanç; Antonio Ros; Luis López-Durán
Journal:  Musculoskelet Surg       Date:  2012-12-30

7.  Midterm results following uncemented, modular, fully porous coated stem used in revision total hip arthroplasty: Comparison of two stem systems.

Authors:  Konrad Sebastian Wronka; Peter Herman Johan Cnudde
Journal:  J Orthop       Date:  2016-07-02

8.  Proximal cement fixation in total hip arthroplasty--first results with a new stem design.

Authors:  Thomas Einsiedel; Florian Gebhard; Ilaria Bregolato; Anja Hiemeier; Lothar Kinzl; Markus Schultheiss
Journal:  Int Orthop       Date:  2007-03-13       Impact factor: 3.075

9.  Subsidence of titanium straight stems in combination with highly viscous bone cement.

Authors:  Christian Hendrich; Ulf Sauer; Tobias Albrecht; Christof P Rader
Journal:  Int Orthop       Date:  2005-02-10       Impact factor: 3.075

10.  Mid-term results using a cementless hip prosthesis in young Chinese patients: a five- to seven-year follow-up study.

Authors:  XueYong Qiu; Jing Yang; Bin Shen; ZongKe Zhou; Hui Zhang; FuXing Pei
Journal:  Int Orthop       Date:  2008-12-03       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.