Accuracy of EBRA-cup measurements after reconstruction of severe acetabular defects at revision THR.

John M Abrahams1,2, Stuart A Callary1,2, Sung W Jang3, Joseph Hewitt1,2, Donald W Howie1,2, Lucian B Solomon1,2.   

Abstract

Radiostereometric analysis (RSA) is the most accurate method of measuring component migration using radiographs but is restricted to use in prospective studies. Ein-Bild-Roentgen-analyze (EBRA)-Cup can be used retrospectively, but its accuracy to measure component migration following revision is unknown. This study aimed to determine the accuracy of EBRA-Cup measurements of uncemented acetabular component migration after revision total hip replacement (THR). The secondary aim was to compare the number of cases identified using EBRA-Cup and RSA as having proximally migrated above and below 1 mm at 2 years postoperatively. EBRA-Cup measurements were performed on plain antero-posterior pelvic radiographs taken at the same time as RSA radiographs in a prospective cohort of 53 hips undergoing acetabular revision. At 2 years, the mean difference between the RSA and EBRA-Cup measurements for 17 components used to treat pelvic discontinuity was 0.90 mm, significantly greater than the mean difference of 0.28 mm for 36 components without discontinuity (P = .0001). The mean difference between the RSA and EBRA-Cup measurements at 2 years for hips that were reconstructed with an acetabular component alone, 0.28 mm, was significantly lower than hips that were reconstructed with an acetabular component in combination with an augment and/or cage, 0.74 mm (P = .0005). In conclusion, EBRA-Cup can accurately measure migration of uncemented acetabular components used at revision THR. The presence of pelvic discontinuity, and addition of augments and cages, significantly influenced the accuracy of EBRA-Cup measurements. EBRA-Cup and RSA had good agreement on classification of components that migrated proximally above or below 1 mm at 2 years, with 100% sensitivity, and 87% specificity.
© 2020 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  arthroplasty-hip; clinical outcomes; diagnostic imaging; hip; implant fixation

Year:  2020        PMID: 32039492     DOI: 10.1002/jor.24623

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  9 in total

1.  Clinical evaluation of a novel press-fit acetabular cup using "Ein-Bild-Roentgen-Analysis" (EBRA): A positive short-term prognosis.

Authors:  B A Ishaque; J Wieczorek; C A Fonseca Ulloa; J B Seeger; G A Ahmed; M Rickert; A Jahnke
Journal:  J Orthop       Date:  2020-03-30

2.  Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-09       Impact factor: 3.067

3.  Outcome and EBRA migration analysis of a reconstruction cage in acetabular revision arthroplasty: a clinical and radiological study.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Annelies van Beeck; Michael Nogler; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-12-22       Impact factor: 3.067

4.  Different wear in two highly cross-linked polyethylene liners in THA: wear analysis with EBRA.

Authors:  D Dammerer; A Keiler; D Putzer; F Lenze; M Liebensteiner; M Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-04       Impact factor: 3.067

5.  EBRA Migration Analysis of a Modular, Distally Fixed Stem in Hip Revision Arthroplasty: A Clinical and Radiological Study.

Authors:  Philipp Blum; David Putzer; Johannes Neugebauer; Markus Neubauer; Markus Süß; Dietmar Dammerer
Journal:  J Clin Med       Date:  2022-10-03       Impact factor: 4.964

6.  High risk of hip dislocation following polyethylene liner exchange in total hip arthroplasty-is cup revision necessary?

Authors:  D Dammerer; F Schneider; T Renkawitz; D Putzer; M Bogensperger; R Biedermann
Journal:  Arch Orthop Trauma Surg       Date:  2020-09-19       Impact factor: 3.067

7.  Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA.

Authors:  Dietmar Dammerer; Alexander Ruzicka; Philipp Blum; David Putzer; Maximilian Liebsch; Julian Lair; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-30       Impact factor: 3.067

8.  Migration characteristics of the Corail hydroxyapatite-coated femoral stem-a retrospective clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Dietmar Krappinger; Christof Pabinger; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2021-05-17       Impact factor: 3.067

Review 9.  Subsidence of a metaphyseal-anchored press-fit stem after 4-year follow-up: an EBRA-FCA analysis.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Dietmar Krappinger; Michael C Liebensteiner; Michael Nogler; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-21       Impact factor: 2.928

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.