Literature DB >> 16761152

Modes of failure of a threaded acetabular cup : a radiographic study with EBRA of 42 revised cups.

Thomas Ilchmann1, Severin Neher, Franz Maurer, Kuno Weise.   

Abstract

A radiographic study of a singular type of threaded cup, revised due to aseptic loosening, was performed with Einzel-Bild-Roentgen-Analyse (EBRA) to detect eventual risk factors and patterns of loosening. Fifty-three cups of 50 patients were revised. Forty-two cups could be measured with EBRA. No cup had obvious osteolysis, 33 cups demonstrated early migration, and all cups had migrated at the time of revision. Twenty-eight of the cups had a change of inclination and 21 of anteversion, respectively. The mean migration was 1.9 mm in the medial and 7.9 mm in the cranial direction; the mean wear rate was 0.2 mm/year. Cups with early migration had a higher migration rate. All male patients had early migration; medially placed cups had less migration than the other cups. Wear was not significantly affected by the migration of the implant. No cup had a complete radiolucent line, and the only radiographic sign for loosening was the change of position of the cup. Medial placement showed less migration in case of loosening. Regular radiographic follow-up is recommended for the examined implant, and the cup should not be used in the future.

Entities:  

Mesh:

Year:  2006        PMID: 16761152      PMCID: PMC2267560          DOI: 10.1007/s00264-006-0155-2

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis.

Authors:  M Krismer; R Biedermann; B Stöckl; M Fischer; R Bauer; C Haid
Journal:  J Bone Joint Surg Br       Date:  1999-03

2.  Survivorship of rough-surfaced threaded acetabular cups. 382 consecutive primary Zweymüller cups followed for 0.2-12 years.

Authors:  C P Delaunay; A I Kapandji
Journal:  Acta Orthop Scand       Date:  1998-08

3.  Early migration predicts late aseptic failure of hip sockets.

Authors:  M Krismer; B Stöckl; M Fischer; R Bauer; P Mayrhofer; M Ogon
Journal:  J Bone Joint Surg Br       Date:  1996-05

4.  Migration and wear of long-term successful Charnley total hip replacements.

Authors:  T Ilchmann; L Markovic; A Joshi; K Hardinge; J Murphy; H Wingstrand
Journal:  J Bone Joint Surg Br       Date:  1998-05

5.  Finite element analysis of acetabular reconstruction. Noncemented threaded cups.

Authors:  R Huiskes
Journal:  Acta Orthop Scand       Date:  1987-12

Review 6.  Radiographic assessment of cup migration and wear after hip replacement.

Authors:  T Ilchmann
Journal:  Acta Orthop Scand Suppl       Date:  1997-10

7.  Factors affecting aseptic failure of fixation after primary Charnley total hip arthroplasty. Multivariate survival analysis.

Authors:  S Kobayashi; K Takaoka; N Saito; K Hisa
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

Review 8.  The theory of early loosening of hip prostheses.

Authors:  B Mjöberg
Journal:  Orthopedics       Date:  1997-12       Impact factor: 1.390

9.  Revision for aseptic loosening of uncemented cups in 4,352 primary total hip prostheses. A report from the Norwegian Arthroplasty Register.

Authors:  L I Havelin; S E Vollset; L B Engesaeter
Journal:  Acta Orthop Scand       Date:  1995-12

10.  Strength of initial mechanical fixation of screw ring acetabular components.

Authors:  M H Kody; J M Kabo; K L Markolf; F J Dorey; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1990-08       Impact factor: 4.176

View more
  6 in total

1.  Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup.

Authors:  Martin Kaipel; Anton Prenner; Sebastian Bachl; Sebastian Farr; Günter Sinz
Journal:  Wien Klin Wochenschr       Date:  2014-01-18       Impact factor: 1.704

Review 2.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

3.  Is there a risk in placing a ceramic head on a previously implanted trunion?

Authors:  Didier Hannouche; Jérôme Delambre; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

4.  Clinical evaluation of a novel press-fit acetabular cup using "Ein-Bild-Roentgen-Analysis" (EBRA): A positive short-term prognosis.

Authors:  B A Ishaque; J Wieczorek; C A Fonseca Ulloa; J B Seeger; G A Ahmed; M Rickert; A Jahnke
Journal:  J Orthop       Date:  2020-03-30

5.  Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-09       Impact factor: 3.067

6.  Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA.

Authors:  Dietmar Dammerer; Alexander Ruzicka; Philipp Blum; David Putzer; Maximilian Liebsch; Julian Lair; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-30       Impact factor: 3.067

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.