Literature DB >> 23523483

Five-year results of the uncemented RM pressfit cup clinical evaluation and migration measurements by EBRA.

Tobias Wyss1, Peter Kägi, Peter Mayrhofer, Hubert Nötzli, Dominik Pfluger, Karl Knahr.   

Abstract

This was a prospective consecutive, study of 50 patients (mean age 72 years, 56% males) treated unilaterally for primary osteoarthrosis using the uncemented, isoelastic, monoblock RM Pressfit Cup. Migration and wear were assessed using the EBRA (Ein-Bild-Röntgen-Analyse) software (201 radiographs from 36 patients). Mean migration was 0.82 mm after 2 years and 1.25 mm after 5 years. A decreasing migration rate over the period was observed. The mean annual wear rate was 0.09 mm/y. Five years after surgery, 84% of patients reached good or excellent Harris hip score values. No revisions related to the acetabular component were necessary. All cups appeared to have high primary stability.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  EBRA; RM Pressfit Cup; migration; total hip arthroplasty

Mesh:

Year:  2013        PMID: 23523483     DOI: 10.1016/j.arth.2012.11.004

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Does a titanium-coated polyethylene press-fit cup give reliable midterm results?

Authors:  Nikki Hooper; Harry Sargeant; Chris Frampton; Gary Hooper
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

2.  Stability of small pegs for cementless implant fixation.

Authors:  Diogo M Geraldes; Ulrich Hansen; Jonathan Jeffers; Andrew A Amis
Journal:  J Orthop Res       Date:  2017-05-23       Impact factor: 3.494

3.  The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.

Authors:  Yama Afghanyar; Sebastian Joser; Jonas Tecle; Philipp Drees; Jens Dargel; Philipp Rehbein; Karl Philipp Kutzner
Journal:  BMC Musculoskelet Disord       Date:  2021-01-23       Impact factor: 2.362

4.  Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-09       Impact factor: 3.067

5.  Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA.

Authors:  Dietmar Dammerer; Alexander Ruzicka; Philipp Blum; David Putzer; Maximilian Liebsch; Julian Lair; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-30       Impact factor: 3.067

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.