Early migration characteristics of a 180° porous-coated cup with 1-mm press fit.

Christoph Stihsen1, Christopher Rath, Roman Radl, Ali A Saalabian, Wilfried Materna, Peter Rehak, Reinhard Windhager.   

Abstract

INTRODUCTION: Evaluation of early cup movement is an important diagnostic tool to predict the likelihood of long-term implant loosening and clinical failure. The investigated cementless cup is clinically proven over 10 years, but there is a paucity of information that accurately describes the migration characteristics of this component.
MATERIALS AND METHODS: We retrospectively analysed the clinical outcome and migration behaviour of 60 Pinnacle 100 shells after an average 3.8-year follow-up (range 2.1-5.4 years). For migration measurement, EBRA (Einzel-Bild-Röntgen-Analyse) digital software was applied. Clinical assessment was performed using the HHS, the UCLA score and the SF-36 health survey.
RESULTS: The clinical outcome showed excellent results with a mean HHS of 95.4 (SD 7.1) and mean UCLA of 6.9 (SD 1.3). All implants were radiologically stable within the observation period and none of the cups was at risk for aseptical loosening. EBRA analysis revealed a mean total migration of 1.4 mm (SD 0.9) (95 % CI 1.1-1.6) at 3 years. Eight cups migrated more than 1 mm within the first three postoperative months, thereafter the migration curves flattened down.
CONCLUSION: Surgeons may expect to find a variable amount of early migration when using the Pinnacle cup. To our knowledge, these are the first results, which show an early "impaction" of a cementless cup, followed by subsequent osseointegration. We believe that an appropriate long-term outcome of the investigated cup is ensured. The data of the present investigation will provide clinicians with useful baseline information with which to compare new cup designs.

Mesh:

Year:  2013        PMID: 23475053     DOI: 10.1007/s00402-013-1713-x

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  Early aseptic loosening of cementless monoblock acetabular components.

Authors:  Simo S A Miettinen; Tatu J Mäkinen; Inari Laaksonen; Keijo Mäkelä; Heini Huhtala; Jukka Kettunen; Ville Remes
Journal:  Int Orthop       Date:  2016-08-10       Impact factor: 3.075

2.  Outcome and EBRA migration analysis of a reconstruction cage in acetabular revision arthroplasty: a clinical and radiological study.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Annelies van Beeck; Michael Nogler; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-12-22       Impact factor: 3.067

3.  Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA.

Authors:  Dietmar Dammerer; Alexander Ruzicka; Philipp Blum; David Putzer; Maximilian Liebsch; Julian Lair; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-30       Impact factor: 3.067

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.