Literature DB >> 32746143

Approximating the Ideal Observer for Joint Signal Detection and Localization Tasks by use of Supervised Learning Methods.

Weimin Zhou, Hua Li, Mark A Anastasio.   

Abstract

Medical imaging systems are commonly assessed and optimized by use of objective measures of image quality (IQ). The Ideal Observer (IO) performance has been advocated to provide a figure-of-merit for use in assessing and optimizing imaging systems because the IO sets an upper performance limit among all observers. When joint signal detection and localization tasks are considered, the IO that employs a modified generalized likelihood ratio test maximizes observer performance as characterized by the localization receiver operating characteristic (LROC) curve. Computations of likelihood ratios are analytically intractable in the majority of cases. Therefore, sampling-based methods that employ Markov-Chain Monte Carlo (MCMC) techniques have been developed to approximate the likelihood ratios. However, the applications of MCMC methods have been limited to relatively simple object models. Supervised learning-based methods that employ convolutional neural networks have been recently developed to approximate the IO for binary signal detection tasks. In this paper, the ability of supervised learning-based methods to approximate the IO for joint signal detection and localization tasks is explored. Both background-known-exactly and background-known-statistically signal detection and localization tasks are considered. The considered object models include a lumpy object model and a clustered lumpy model, and the considered measurement noise models include Laplacian noise, Gaussian noise, and mixed Poisson-Gaussian noise. The LROC curves produced by the supervised learning-based method are compared to those produced by the MCMC approach or analytical computation when feasible. The potential utility of the proposed method for computing objective measures of IQ for optimizing imaging system performance is explored.

Entities:  

Mesh:

Year:  2020        PMID: 32746143      PMCID: PMC7768793          DOI: 10.1109/TMI.2020.3009022

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  "Proper" Binormal ROC Curves: Theory and Maximum-Likelihood Estimation.

Authors: 
Journal:  J Math Psychol       Date:  1999-03       Impact factor: 2.223

2.  Visual detection and localization of radiographic images.

Authors:  S J Starr; C E Metz; L B Lusted; D J Goodenough
Journal:  Radiology       Date:  1975-09       Impact factor: 11.105

3.  Experimental determination of object statistics from noisy images.

Authors:  Matthew A Kupinski; Eric Clarkson; John W Hoppin; Liying Chen; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2003-03       Impact factor: 2.129

4.  Ideal-observer computation in medical imaging with use of Markov-chain Monte Carlo techniques.

Authors:  Matthew A Kupinski; John W Hoppin; Eric Clarkson; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2003-03       Impact factor: 2.129

5.  A comparison of human and model observers in multislice LROC studies.

Authors:  Howard C Gifford; Michael A King; P Hendrik Pretorius; R Glenn Wells
Journal:  IEEE Trans Med Imaging       Date:  2005-02       Impact factor: 10.048

6.  Aperture optimization for emission imaging: effect of a spatially varying background.

Authors:  K J Myers; J P Rolland; H H Barrett; R F Wagner
Journal:  J Opt Soc Am A       Date:  1990-07       Impact factor: 2.129

7.  Deep Convolutional Neural Networks for Image Classification: A Comprehensive Review.

Authors:  Waseem Rawat; Zenghui Wang
Journal:  Neural Comput       Date:  2017-06-09       Impact factor: 2.026

8.  Toward realistic and practical ideal observer (IO) estimation for the optimization of medical imaging systems.

Authors:  Xin He; Brian S Caffo; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

9.  Optimal Joint Detection and Estimation That Maximizes ROC-Type Curves.

Authors:  Adam Wunderlich; Bart Goossens; Craig K Abbey
Journal:  IEEE Trans Med Imaging       Date:  2016-04-13       Impact factor: 10.048

10.  Collimator optimization in SPECT based on a joint detection and localization task.

Authors:  Lili Zhou; Gene Gindi
Journal:  Phys Med Biol       Date:  2009-06-26       Impact factor: 3.609

View more
  2 in total

1.  Learning stochastic object models from medical imaging measurements by use of advanced ambient generative adversarial networks.

Authors:  Weimin Zhou; Sayantan Bhadra; Frank J Brooks; Hua Li; Mark A Anastasio
Journal:  J Med Imaging (Bellingham)       Date:  2022-02-23

2.  A Hybrid Approach for Approximating the Ideal Observer for Joint Signal Detection and Estimation Tasks by Use of Supervised Learning and Markov-Chain Monte Carlo Methods.

Authors:  Kaiyan Li; Weimin Zhou; Hua Li; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2022-05-02       Impact factor: 11.037

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.