Literature DB >> 19556684

Collimator optimization in SPECT based on a joint detection and localization task.

Lili Zhou1, Gene Gindi.   

Abstract

In SPECT the collimator is a crucial element of the imaging chain and controls the noise-resolution tradeoff of the collected data. Optimizing collimator design has been a long studied topic, with many different criteria used to evaluate the design. One class of criteria is task based, in which the collimator is designed to optimize detection of a signal (lesion). Here we consider a new, more realistic task, the joint detection and localization of a signal. Furthermore, we use an ideal observer-one that attains a theoretically maximum task performance-to optimize collimator design. The ideal observer operates on the sinogram data. We consider a family of parallel-hole low-energy collimators of varying resolution and efficiency and optimize over this set. We observe that for a 2D object characterized by noise due to background variability and a sinogram with photon noise, the optimal collimator tends to be of lower resolution and higher efficiency than equivalent commercial collimators. Furthermore, this optimal design is insensitive to the tolerance radius within which the signal must be localized. So for this scenario, the addition of a localization task does not change the optimal collimator. Optimal collimator resolution gets worse as signal size grows, and improves as the level of background variability noise increases. These latter two trends are also observed when the detection task is signal-known-exactly and background variable.

Entities:  

Mesh:

Year:  2009        PMID: 19556684      PMCID: PMC2860871          DOI: 10.1088/0031-9155/54/14/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  An accelerated convergent ordered subsets algorithm for emission tomography.

Authors:  Ing-Tsung Hsiao; Anand Rangarajan; Parmeshwar Khurd; Gene Gindi
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

2.  Experimental task-based optimization of a four-camera variable-pinhole small-animal SPECT system.

Authors:  Jacob Y Hesterman; Matthew A Kupinski; Lars R Furenlid; Donald W Wilson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005-02-12

3.  Decision strategies that maximize the area under the LROC curve.

Authors:  Parmeshwar Khurd; Gene Gindi
Journal:  IEEE Trans Med Imaging       Date:  2005-12       Impact factor: 10.048

4.  Small nodule detectability evaluation using a generalized scan-statistic model.

Authors:  Lucreţiu M Popescu; Robert M Lewitt
Journal:  Phys Med Biol       Date:  2006-11-15       Impact factor: 3.609

5.  Aperture optimization for emission imaging: effect of a spatially varying background.

Authors:  K J Myers; J P Rolland; H H Barrett; R F Wagner
Journal:  J Opt Soc Am A       Date:  1990-07       Impact factor: 2.129

6.  Ideal AFROC and FROC observers.

Authors:  Parmeshwar Khurd; Bin Liu; Gene Gindi
Journal:  IEEE Trans Med Imaging       Date:  2010-02       Impact factor: 10.048

7.  Collimator optimization for lesion detection incorporating prior information about lesion size.

Authors:  S C Moore; D J deVries; B Nandram; M F Kijewski; S P Mueller
Journal:  Med Phys       Date:  1995-06       Impact factor: 4.071

8.  A comparison of optimum detector spatial resolution in nuclear imaging based on statistical theory and on observer performance.

Authors:  B M Tsui; C E Metz; F B Atkins; S J Starr; R N Beck
Journal:  Phys Med Biol       Date:  1978-07       Impact factor: 3.609

9.  Efficiency of the human observer detecting random signals in random backgrounds.

Authors:  Subok Park; Eric Clarkson; Matthew A Kupinski; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2005-01       Impact factor: 2.129

10.  Impact of Mismatched Detector-Blur Models on Ga SPECT Tumor Detection.

Authors:  H C Gifford; M A King
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007
View more
  11 in total

Review 1.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Joint optimization of collimator and reconstruction parameters in SPECT imaging for lesion quantification.

Authors:  Sarah J McQuaid; Sudeepti Southekal; Marie Foley Kijewski; Stephen C Moore
Journal:  Phys Med Biol       Date:  2011-11-07       Impact factor: 3.609

Review 3.  Task-based measures of image quality and their relation to radiation dose and patient risk.

Authors:  Harrison H Barrett; Kyle J Myers; Christoph Hoeschen; Matthew A Kupinski; Mark P Little
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

4.  Assessment of cardiac single-photon emission computed tomography performance using a scanning linear observer.

Authors:  Chih-Jie Lee; Matthew A Kupinski; Lana Volokh
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

6.  Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.

Authors:  Michael Ghaly; Yong Du; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

7.  Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric Frey
Journal:  J Med Imaging (Bellingham)       Date:  2015-01

8.  Design Studies of a CZT-based Detector Combined with a Pixel-Geometry-Matching Collimator for SPECT Imaging.

Authors:  Fenghua Weng; Srijeeta Bagchi; Qiu Huang; Youngho Seo
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2013-10

9.  Approximating the Ideal Observer for Joint Signal Detection and Localization Tasks by use of Supervised Learning Methods.

Authors:  Weimin Zhou; Hua Li; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

10.  Optimal Joint Detection and Estimation That Maximizes ROC-Type Curves.

Authors:  Adam Wunderlich; Bart Goossens; Craig K Abbey
Journal:  IEEE Trans Med Imaging       Date:  2016-04-13       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.