Literature DB >> 15707242

A comparison of human and model observers in multislice LROC studies.

Howard C Gifford1, Michael A King, P Hendrik Pretorius, R Glenn Wells.   

Abstract

Model and human observers have been compared in a series of localization receiver operating characteristic (LROC) studies involving single-slice and multislice image displays. The task was detection of Ga-avid lymphomas within single photon emission computed tomography (SPECT)-reconstructed transverse slices of a mathematical phantom, and the studies involved four reconstruction strategies: the filtered-backprojection (FBP) and ordered-subset expectation-maximization (OSEM) algorithms with two- and three-dimensional postreconstruction filtering. The human-observer data was drawn from studies performed by Wells et al. (2000), while multiclass versions of the nonprewhitening (NPW), channelized nonprewhitening (CNPW), and channelized Hotelling (CH) model observers, each capable of performing the tumor search task, were applied. The channelized observers were evaluated with multiple square-channel models and both with and without internal noise. For the multislice studies, two different capacities for integrating the slice information were also tested. The CH observer gave good quantitative agreement with the human data from both image-display studies when the internal-noise model was used. The CNPW observer performed similarly with the iterative strategies. Wells et al. had shown that human observers are imperfect integrators of multislice information, and this is characterized as increased internal noise with the model observers.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15707242     DOI: 10.1109/tmi.2004.839362

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  38 in total

1.  Rapid Optimization of SPECT Scatter Correction Using Model LROC Observers.

Authors:  Santosh Kulkarni; Parmeshwar Khurd; Lili Zhou; Gene Gindi
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

2.  Anthropomorphic model observer performance in three-dimensional detection task for low-contrast computed tomography.

Authors:  Alexandre Ba; Miguel P Eckstein; Damien Racine; Julien G Ott; Francis Verdun; Sabine Kobbe-Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-29

3.  Channelized Hotelling observer correlation with human observers for low-contrast detection in liver CT images.

Authors:  Alexandre Ba; Craig K Abbey; Damien Racine; Anaïs Viry; Francis R Verdun; Sabine Schmidt; François O Bochud
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-20

4.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

5.  A Vector Uniform Cramer-Rao Bound for SPECT System Design.

Authors:  Ling-Jian Meng; Nan Li
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

6.  An Evaluation of Iterative Reconstruction Strategies on Mediastinal Lesion Detection Using Hybrid Ga-67 SPECT Images.

Authors:  N F Pereira; H C Gifford; P H Pretorius; T Farncombe; M Smyczynski; R Licho; P Schneider; M A King
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

7.  A visual-search model observer for multislice-multiview SPECT images.

Authors:  Howard C Gifford
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

8.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

9.  Aperture optimization in emission imaging using ideal observers for joint detection and localization.

Authors:  Lili Zhou; Parmeshwar Khurd; Santosh Kulkarni; Anand Rangarajan; Gene Gindi
Journal:  Phys Med Biol       Date:  2008-03-26       Impact factor: 3.609

10.  Approximating the Ideal Observer for Joint Signal Detection and Localization Tasks by use of Supervised Learning Methods.

Authors:  Weimin Zhou; Hua Li; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.