Literature DB >> 10069933

"Proper" Binormal ROC Curves: Theory and Maximum-Likelihood Estimation.

.   

Abstract

The conventional binormal model, which assumes that a pair of latent normal decision-variable distributions underlies ROC data, has been used successfully for many years to fit smooth ROC curves. However, if the conventional binormal model is used for small data sets or ordinal-category data with poorly allocated category boundaries, a "hook" in the fitted ROC may be evident near the upper-right or lower-left corner of the unit square. To overcome this curve-fitting artifact, we developed a "proper" binormal model and a new algorithm for maximum-likelihood (ML) estimation of the corresponding ROC curves. Extensive simulation studies have shown the algorithm to be highly reliable. ML estimates of the proper and conventional binormal ROC curves are virtually identical when the conventional binormal ROC shows no "hook," but the proper binormal curves have monotonic slope for all data sets, including those for which the conventional model produces degenerate fits. Copyright 1999 Academic Press.

Entities:  

Year:  1999        PMID: 10069933     DOI: 10.1006/jmps.1998.1218

Source DB:  PubMed          Journal:  J Math Psychol        ISSN: 0022-2496            Impact factor:   2.223


  82 in total

1.  Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization.

Authors:  Mitra Noroozian; Lubomir Hadjiiski; Sahand Rahnama-Moghadam; Katherine A Klein; Deborah O Jeffries; Renee W Pinsky; Heang-Ping Chan; Paul L Carson; Mark A Helvie; Marilyn A Roubidoux
Journal:  Radiology       Date:  2011-10-13       Impact factor: 11.105

2.  Improved detection of focal pneumonia by chest radiography with bone suppression imaging.

Authors:  Feng Li; Roger Engelmann; Lorenzo Pesce; Samuel G Armato; Heber Macmahon
Journal:  Eur Radiol       Date:  2012-07-05       Impact factor: 5.315

Review 3.  ROC analysis in medical imaging: a tutorial review of the literature.

Authors:  Charles E Metz
Journal:  Radiol Phys Technol       Date:  2007-10-27

4.  Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD.

Authors:  Keita Takahashi; Junji Morishita; Takeshi Hiwasa; Shiro Hatanaka; Shuji Sakai; Noriyuki Hashimoto; Yasuhiko Nakamura; Fukai Toyofuku; Yoshiharu Higashida; Masafumi Ohki
Journal:  Radiol Phys Technol       Date:  2010-06-12

5.  Detectability of a lung nodule displayed on a liquid-crystal display monitor with different maximum luminance settings.

Authors:  Keita Takahashi; Masaki Sueoka; Yongsu Yoon; Takeshi Hiwasa; Shiro Hatanaka; Yasuhiko Nakamura; Noriyuki Hashimoto; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2009-09-01

6.  Use of likelihood ratios for comparisons of binary diagnostic tests: underlying ROC curves.

Authors:  Andriy I Bandos; Howard E Rockette; David Gur
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

7.  Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: validation on a physical dynamic cardiac phantom.

Authors:  Martin King; Zachary Rodgers; Maryellen L Giger; Dianna M E Bardo; Amit R Patel
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

8.  Comparison of semiparametric receiver operating characteristic models on observer data.

Authors:  Frank W Samuelson; Xin He
Journal:  J Med Imaging (Bellingham)       Date:  2014-08-28

9.  Lung texture in serial thoracic CT scans: correlation with radiologist-defined severity of acute changes following radiation therapy.

Authors:  Alexandra R Cunliffe; Samuel G Armato; Christopher Straus; Renuka Malik; Hania A Al-Hallaq
Journal:  Phys Med Biol       Date:  2014-08-26       Impact factor: 3.609

10.  Reliable and computationally efficient maximum-likelihood estimation of "proper" binormal ROC curves.

Authors:  Lorenzo L Pesce; Charles E Metz
Journal:  Acad Radiol       Date:  2007-07       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.