| Literature DB >> 32211484 |
Paul Magill1, Janet Hill1, Seamus O'Brien1, Michael Stevenson2, Alain Machenaud3, David Beverland1.
Abstract
BACKGROUND: The objective of this study was to determine the prevalence of radiolucent lines (RLLs) around the femoral component in a cohort of patients who underwent well-functioning cementless total hip arthroplasty (THA).Entities:
Keywords: Cementless; Collar; Corail; Hip; Templating; Uncemented
Year: 2020 PMID: 32211484 PMCID: PMC7083744 DOI: 10.1016/j.artd.2019.11.009
Source DB: PubMed Journal: Arthroplast Today ISSN: 2352-3441
Figure 1Plain radiograph comparison of a KS collarless (a and b) and KA collared (c) corail cementless femoral component, both at ten years after implantation, and both in patients with no pain. Note in 1a and 1b the radiolucent lines in Gruen zones 1,7,8 and 14.
Figure 2Implant choices and operative technique changes during the catchment period of the study. Only reviewed stems (n = 636) included. NXLPE, non cross-linked polyethylene; XLPE, cross-linked polyethylene; CoC, ceramic on ceramic; CoM, ceramic on metal; MoM, metal on metal..
Demographics of study participants.
| Implant | KS (n = 159) | KHO (n = 159) | KA (n = 161) | KLA (n = 157) |
|---|---|---|---|---|
| Variable | ||||
| Median follow-up in years (IQR) | 7.0 (6.0-7.0) | 6.5 (6.2-6.9) | 5.4 (5.1-5.8) | 5.1 (4.7-5.5) |
| Median patient age in years at time of surgery (IQR) | 65 (62-68) | 65 (62-68) | 64 (58-68) | 63 (58-67) |
| Median stem size (IQR) | 11 (9-12) | 11 (10-13) | 10 (9-12) | 11 (10-12) |
| Pinnacle acetabular component, % | 100 | 100 | 100 | 100 |
| Female, number (%) | 102 (64.6%) | 61 (38.4%) | 135 (84.0%) | 53 (33.7%) |
| Bearing type, n (% per stem) | ||||
| Metal on NXLPE | 25 (15.7%) | 24 (15.1%) | 3 (1.9%) | 2 (1.3%) |
| Metal on XLPE | 0 | 0 | 84 (52.2%) | 80 (51.0%) |
| Ceramic on NXLPE | 77 (48.4%) | 84 (52.8%) | 0 | 3 (1.9%) |
| Ceramic on XLPE | 0 | 0 | 1 (0.6%) | 0 |
| CoC | 57 (35.8%) | 50 (31.4%) | 5 (3.1%) | 36 (22.9%) |
| CoM | 0 | 1 (0.6%) | 67 (41.6%) | 35 (22.3%) |
| MoM | 0 | 0 | 1 (0.6%) | 1 (0.6%) |
CoC, ceramic on ceramic; CoM, ceramic on metal; IQR, interquartile range; MoM, metal on metal.
Prevalence outcome from the radiographic analysis of the 636 femoral components at latest follow-up.
| Radiographic report | All stems n = 636 | Collarless cohort | Collared cohort | |||||
|---|---|---|---|---|---|---|---|---|
| Total (n = 318) | KHO (n = 159) | KS (n = 159) | Total (n = 318) | KA (n = 161) | KLA (n = 157) | |||
| RLL any zone | 260 (40.9%) | 141 (44.3%) | 80 (50.3%) | 61 (38.4%) | 119 (37.4%) | 53 (32.9%) | 66 (42.0%) | .08 |
| RLL only zone 1 and/or 8 | 137 (21.5%) | 35 (11.0%) | 24 (15.1%) | 11 (6.9%) | 103 (32.4%) | 45 (28.0%) | 58 (36.9%) | <.001 |
| Any RLL pattern involving zone 7 | 83 (13.1%) | 75 (23.6%) | 50 (31.4%) | 25 (15.7%) | 8 (2.6%) | 2 (1.2%) | 6 (3.8%) | <.001 |
| Undersized by 2 sizes or more | 58 (9.1%) | 25 (7.9%) | 17 (10.7%) | 8 (5.0%) | 33 (10.4%) | 20 (12.4%) | 13 (8.3%) | .27 |
Comparing collarless and collared cohorts using the Chi-square test.
Results of multivariable analysis on the collarless cohort with respect to the presence of any RLL involving zone 7.
| Variable | Odds ratio | 95% CI | Interpretation | |
|---|---|---|---|---|
| Non–cross-linked polyethylene | 1.3 | 0.7-2.2 | .42 | NXLPE is not a significant factor for development of RLL in zone 7 |
| Undersized ≥2 sizes | 2.6 | 1.1-6.2 | .03 | If a femoral component is undersized ≥ 2 sizes, it is 2.6 times more likely to develop RLL in zone 7 |
| Follow-up years | 0.6 | 0.4-0.9 | .01 | RLL in zone 7 is seen in those with shorter follow-up |
CI, confidence interval.