Literature DB >> 26811959

Long-term Results of a First-Generation Annealed Highly Cross-Linked Polyethylene in Young, Active Patients.

Chitranjan S Ranawat, Amar S Ranawat, Alankar A Ramteke, Danyal Nawabi, Morteza Meftah.   

Abstract

The survivorship of total hip arthroplasty in younger patients is dependent on the wear characteristics of the bearing surfaces. Long-term results with conventional polyethylene in young patients show a high failure rate. This study assessed the long-term results of a first-generation annealed highly cross-linked polyethylene (HCLPE) in uncemented total hip arthroplasty in young, active patients. Between 1999 and 2003, 112 total hip arthroplasty procedures performed in 91 patients with an average University of California Los Angeles activity score of 8 and mean age of 53 years (range, 24-65 years) were included from a prospective database. In all patients, a 28-mm metal femoral head on annealed HCLPE (Crossfire; Stryker, Mahwah, New Jersey) was used. At minimum 10-year follow-up (11.5±0.94 years), Kaplan-Meier survivorship was 97% for all failures (1 periprosthetic infection and 1 late dislocation) and 100% for mechanical failure (no revisions for osteolysis or loosening). This study showed low revision rates for wear-related failure and superior survivorship in young, active patients. Oxidation causing failure of the locking mechanism has not been a problem with Crossfire for up to 10 years. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26811959     DOI: 10.3928/01477447-20160119-02

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

Review 1.  Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.

Authors:  Julio J Jauregui; Joseph K Kim; William P Shield; Matthew Harb; Emmanuel M Illical; Farshad Adib; Aditya V Maheshwari
Journal:  Int Orthop       Date:  2017-03-27       Impact factor: 3.075

2.  Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

Authors:  Rajkumar Thangaraj; Jan Kuiper; Ralph D Perkins
Journal:  J Clin Orthop Trauma       Date:  2018-01-03

3.  Third-Generation Medium Cross-Linked Polyethylene Demonstrates Very Low Wear in Total Hip Arthroplasty.

Authors:  Omid Jalali; Travis Scudday; Marie-Claire Fickenscher; Steven Barnett; Robert Gorab
Journal:  Arthroplast Today       Date:  2020-06-02

4.  Observed effect of femoral component undersizing and a collarless design in the development of radiolucent lines in cementless total hip arthroplasty.

Authors:  Paul Magill; Janet Hill; Seamus O'Brien; Michael Stevenson; Alain Machenaud; David Beverland
Journal:  Arthroplast Today       Date:  2020-01-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.