Literature DB >> 25737511

Early surveillance of ceramic-on-metal total hip arthroplasty.

J C Hill1, O J Diamond1, S O'Brien1, J G Boldt2, M Stevenson3, D E Beverland1.   

Abstract

Ceramic-on-metal (CoM) is a relatively new bearing combination for total hip arthroplasty (THA) with few reported outcomes. A total of 287 CoM THAs were carried out in 271 patients (mean age 55.6 years (20 to 77), 150 THAs in female patients, 137 in male) under the care of a single surgeon between October 2007 and October 2009. With the issues surrounding metal-on-metal bearings the decision was taken to review these patients between March and November 2011, at a mean follow-up of 34 months (23 to 45) and to record pain, outcome scores, radiological analysis and blood ion levels. The mean Oxford Hip Score was 19.2 (12 to 53), 254 patients with 268 hips (95%) had mild/very mild/no pain, the mean angle of inclination of the acetabular component was 44.8(o) (28(o) to 63(o)), 82 stems (29%) had evidence of radiolucent lines of > 1 mm in at least one Gruen zone and the median levels of cobalt and chromium ions in the blood were 0.83 μg/L (0.24 μg/L to 27.56 μg/L) and 0.78 μg/L (0.21 μg/L to 8.84 μg/L), respectively. The five-year survival rate is 96.9% (95% confidence interval 94.7% to 99%). Due to the presence of radiolucent lines and the higher than expected levels of metal ions in the blood, we would not recommend the use of CoM THA without further long-term follow-up. We plan to monitor all these patients regularly. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  ceramic-on-metal; hard on hard bearings; total hip replacement

Mesh:

Substances:

Year:  2015        PMID: 25737511     DOI: 10.1302/0301-620X.97B3.33242

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  5 in total

1.  Pseudotumor in ceramic-on-metal total hip arthroplasty.

Authors:  Yoni M Blau; Andrew J Meyers; Mauro Giordani; John P Meehan
Journal:  Arthroplast Today       Date:  2017-10-06

2.  Clinical Results and Serum Metal Ion Concentrations following Ceramic-on-Metal Total Hip Arthroplasty at a Mean Follow-Up of 60 Months.

Authors:  W Maurer-Ertl; D Pranckh-Matzke; J Friesenbichler; G Bratschitsch; L A Holzer; M Maier; A Leithner
Journal:  Biomed Res Int       Date:  2017-03-08       Impact factor: 3.411

3.  Ceramic-on-metal coupling in THA: long term clinical and radiographic outcomes using two different short stems.

Authors:  Giandomenico Logroscino; Michela Saracco; Giulio Maccauro; Andrea Urbani; Domenico Ciavardelli; Ada Consalvo; Daniele Ferraro; Francesco Falez
Journal:  BMC Musculoskelet Disord       Date:  2022-02-22       Impact factor: 2.362

4.  Functional outcomes & metal ion levels following ceramic on metal total hip arthroplasty: 9 Year follow-up.

Authors:  Nisarg Mehta; Dhawal Patel; Justin Leong; Phil Brown; Fintan Adrian Carroll
Journal:  J Orthop       Date:  2021-02-23

5.  Observed effect of femoral component undersizing and a collarless design in the development of radiolucent lines in cementless total hip arthroplasty.

Authors:  Paul Magill; Janet Hill; Seamus O'Brien; Michael Stevenson; Alain Machenaud; David Beverland
Journal:  Arthroplast Today       Date:  2020-01-06
  5 in total