Literature DB >> 21570801

Does a collar improve the immediate stability of uncemented femoral hip stems in total hip arthroplasty? A bilateral comparative cadaver study.

Guillaume Demey1, Camdon Fary, Sébastien Lustig, Philippe Neyret, Tarik Aït si Selmi.   

Abstract

The aim of this study was to compare the immediate stability of collared vs collarless uncemented femoral stems in total hip arthroplasty. A bilateral comparative study of 20 cadavers (40 hips: 20 collarless, 20 collared) was performed. Forces in the vertical and horizontal planes required to initiate subsidence of femoral stem and subsequent femoral fracture were measured. In vertical plane, subsidence began at an average force of 3129 ± 494 N for collarless stems and 6283 ± 3584 N for collared stems (P = .02). Fracture occurred at a significantly higher force for collared stems (P = <.001). In horizontal plane, subsidence began at an average force of 540 ± 170 N for collarless stems and 678 ± 206 N for collared stems (P = .01). Fracture occurred at a significantly higher force for collared stems (P = .005). Collared uncemented stems have significantly greater immediate stability than collarless. They are able to withstand greater vertical and horizontal forces before the initiation of subsidence and subsequent fracture. Crown
Copyright © 2011. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21570801     DOI: 10.1016/j.arth.2011.03.030

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Comparative outcomes between collared versus collarless and short versus long stem of direct anterior approach total hip arthroplasty: a systematic review and indirect meta-analysis.

Authors:  Phonthakorn Panichkul; Suthorn Bavonratanavech; Alisara Arirachakaran; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-07-30

2.  Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography.

Authors:  Valérie Malfroy Camine; Hannes A Rüdiger; Dominique P Pioletti; Alexandre Terrier
Journal:  Int Orthop       Date:  2017-06-07       Impact factor: 3.075

3.  Long-term survivorship of a monoblock long cementless stem in revision total hip arthroplasty.

Authors:  Yannick Herry; Anthony Viste; Hugo Bothorel; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2018-10-01       Impact factor: 3.075

4.  Protrusio After Medial Acetabular Wall Breach in Total Hip Arthroplasty.

Authors:  Christopher T Martin; Anneliese D Heiner; Thomas E Baer; Andrew J Pugely; Nicolas O Noiseux
Journal:  Iowa Orthop J       Date:  2015

5.  Total Hip Replacement Revision in a Single Brand Small Cementless Stem - Our Experience after the Findings of the National Joint Registry.

Authors:  Robert Pearse Piggott; Rebecca Lyons; Colin Gerard Murphy; William Curtin
Journal:  Arch Bone Jt Surg       Date:  2018-11

Review 6.  Long-term survival of CLS Spotorno femoral stem: a systematic review of literature.

Authors:  Mandeep Singh Dhillon; Karan Jindal; Prasoon Kumar; Rajesh Kumar Rajnish; Deepak Neradi
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-06       Impact factor: 3.067

7.  Comparison of short-stem with conventional-stem prostheses in total hip arthroplasty: an 8-year follow-up study.

Authors:  Alexander Zimmerer; Stefanie Slouka; Stefan Kinkel; Thomas Fritz; Stefan Weiss; Christian Sobau; Wolfgang Miehlke
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-22       Impact factor: 2.928

8.  The influence of femoral component design on postoperative periprosthetic femoral fracture after uncemented direct anterior total hip arthroplasty in the elderly.

Authors:  R M Fuller; D I Wicker; C P Christensen
Journal:  J Orthop       Date:  2021-05-14

9.  Design modifications of the uncemented Furlong hip stem result in minor early subsidence but do not affect further stability: a randomized controlled RSA study with 5-year follow-up.

Authors:  Erik Weber; Martin Sundberg; Gunnar Flivik
Journal:  Acta Orthop       Date:  2014-09-01       Impact factor: 3.717

10.  Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?

Authors:  Nicolas Bonin; Jean-Emmanuel Gedouin; Vincent Pibarot; Jacques Bejui-Hughues; Hugo Bothorel; Mo Saffarini; Cécile Batailler
Journal:  J Exp Orthop       Date:  2017-10-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.