Literature DB >> 26530645

A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components.

J Langlois1, F Atlan1, C Scemama1, J P Courpied1, M Hamadouche1.   

Abstract

Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component. We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components. A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed. After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (sd 0.108): in the annealed group it was 0.1382 mm/year (sd 0.129) (Mann-Whitney U test, p < 0.001). No complication specific to either material was recorded. These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  cemented cup; highly cross-linked polyethylene; total hip arthroplasty

Mesh:

Substances:

Year:  2015        PMID: 26530645     DOI: 10.1302/0301-620X.97B11.36219

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  7 in total

1.  Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study.

Authors:  Gaël Gaudin; André Ferreira; Romain Gaillard; Jean Louis Prudhon; Jacques H Caton; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-22       Impact factor: 3.075

2.  Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.

Authors:  Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2016-11-04       Impact factor: 3.075

3.  A higher degree of polyethylene irradiation is associated with a reduced risk of revision for aseptic loosening in total hip arthroplasties using cemented acetabular components: an analysis of 290,770 cases from the National Joint Registry of England, Wales, Northern Island and the Isle of Man.

Authors:  Edward T Davis; Joseph Pagkalos; Branko Kopjar
Journal:  Bone Joint Res       Date:  2020-09-20       Impact factor: 5.853

4.  Radiographic evaluation of linear wear of bipolar hemiarthroplasty devices in vivo.

Authors:  Nobuhiro Kaku; Shouhei Noda; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2018-07-20

5.  Surgical trial design - learning curve and surgeon volume: Determining whether inferior results are due to the procedure itself, or delivery of the procedure by the surgeon.

Authors:  A H R W Simpson; C R Howie; J Norrie
Journal:  Bone Joint Res       Date:  2017-04       Impact factor: 5.853

6.  Observed effect of femoral component undersizing and a collarless design in the development of radiolucent lines in cementless total hip arthroplasty.

Authors:  Paul Magill; Janet Hill; Seamus O'Brien; Michael Stevenson; Alain Machenaud; David Beverland
Journal:  Arthroplast Today       Date:  2020-01-06

Review 7.  Overview of Randomized Controlled Trials in Primary Total Hip Arthroplasty (34,020 Patients): What Have We Learnt?

Authors:  Hosam E Matar; Simon R Platt; Tim N Board; Martyn L Porter
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.