Literature DB >> 26680411

Long-term Bone Remodeling in HA-coated Stems: A Radiographic Review of 208 Total Hip Arthroplasties (THAs) with 15 to 20 Years Follow-up.

Jens G Boldt1, Jean-Claude Cartillier2, Alain Machenaud3, Jean-Pierre Vidalain3.   

Abstract

We present a prospective study focused on radiographic long-term outcomes and bone remodeling at a mean of 17.0 years (range: 15 to 20) in 208 cementless fully HA-coated femoral stems (Corail, DePuy International Ltd, Leeds, UK). Total hip replacements in this study were performed by three members of the surgeon design group between 1986 and 1991. Radiographic evaluation focused on periprosthetic osteolysis, bone remodeling, osseous integration, subsidence, metaphyseal or diaphyseal load transfer, and femoral stress shielding. The radiographs were digitized and examined with contrast-enhancing software for analysis of the trabecular architecture. Radiographic signs of aseptic stem loosening were visible in two cases (1%). Three stems (1.4%) showed metaphyseal periprosthetic osteolysis in four of seven Gruen zones associated with eccentric polyethylene wear awaiting metaphyseal bone grafting and cup liner exchange. One stem (0.5%) was revised due to infection. No stem altered in varus or valgus alignment more than two degrees, and mean subsidence was 0.1 mm (range: 0 to 2 mm) after a mean of 17.0 years. A total of 5 stems (2.4%) required or are awaiting revision surgery. Trabecular orientation and micro-anatomy suggested main proximal load-transfer patterns in all except 3 cases (98.6%). Combined metaphyseal and diaphyseal osseointegration and bone remodeling were visible in 100 stems (48%). Diaphyseal stress shielding and cortical thickening were observed in 3 stems (1.4%). Other radiographic features are discussed in depth. This long-term study of 208 fully HA-coated Corail stems showed satisfactory osseointegration and fixation in 203 cases (97.6%) after a mean of 17.0 years follow-up. Stem failures were associated with extreme eccentric polyethylene wear.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26680411

Source DB:  PubMed          Journal:  Surg Technol Int        ISSN: 1090-3941


  3 in total

1.  The direct anterior approach provokes varus stem alignment when using a collarless straight tapered stem.

Authors:  Marcel Haversath; Martin Lichetzki; Sebastian Serong; André Busch; Stefan Landgraeber; Marcus Jäger; Tjark Tassemeier
Journal:  Arch Orthop Trauma Surg       Date:  2020-05-30       Impact factor: 3.067

2.  Observed effect of femoral component undersizing and a collarless design in the development of radiolucent lines in cementless total hip arthroplasty.

Authors:  Paul Magill; Janet Hill; Seamus O'Brien; Michael Stevenson; Alain Machenaud; David Beverland
Journal:  Arthroplast Today       Date:  2020-01-06

3.  Straight stem and threaded cup in patients under 60 years of age: 28.8-30.2 years of follow-up.

Authors:  L Pisecky; J Allerstorfer; B Schauer; G Hipmair; R Hochgatterer; N Böhler; T Gotterbarm; M C Klotz
Journal:  J Orthop Surg Res       Date:  2020-11-26       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.