Literature DB >> 27909119

Impact of a learning curve on the survivorship of 4802 cementless total hip arthroplasties.

P Magill1, J Blaney1, J C Hill1, M P Bonnin2, D E Beverland1.   

Abstract

AIMS: Our aim was to report survivorship data and lessons learned with the Corail/Pinnacle cementless total hip arthroplasty (THA) system. PATIENTS AND METHODS: Between August 2005 and March 2015, a total of 4802 primary cementless Corail/Pinnacle THAs were performed in 4309 patients. In March 2016, we reviewed these hips from a prospectively maintained database.
RESULTS: A total of 80 hips (1.67%) have been revised which is equivalent to a cumulative risk of revision of 2.5% at ten years. The rate of revision was not significantly higher in patients aged ≥ 70 years (p = 0.93). The leading indications for revision were instability (n = 22, 0.46%), infection (n = 20, 0.42%), aseptic femoral loosening (n = 15, 0.31%) and femoral fracture (n = 6, 0.12%). There were changes in the surgical technique with respect to the Corail femoral component during the ten-year period involving a change to collared components and a trend towards larger size. These resulted in a decrease in the rate of iatrogenic femoral fracture and a decrease in the rate of aseptic loosening.
CONCLUSION: The rate of revision in this series is comparable with the best performing THAs in registry data. Most revisions were not directly related to the implants. Despite extensive previous experience with cemented femoral components, the senior author noted a learning curve requiring increased focus on primary stability. The number of revisions related to the femoral component is reducing. Any new technology has a learning curve that may be independent of surgical experience. Cite this article: Bone Joint J 2016;98-B:1589-96. ©2016 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Cementless; Corail; Hip; Pinnacle; Revision; Uncemented

Mesh:

Substances:

Year:  2016        PMID: 27909119     DOI: 10.1302/0301-620X.98B12.BJJ-2016-0203.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  9 in total

1.  CORR Insights®: Is Cemented or Cementless Femoral Stem Fixation More Durable in Patients Older Than 75 Years of Age? A Comparison of the Best-performing Stems.

Authors:  Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2018-07       Impact factor: 4.176

2.  Total Hip Replacement Revision in a Single Brand Small Cementless Stem - Our Experience after the Findings of the National Joint Registry.

Authors:  Robert Pearse Piggott; Rebecca Lyons; Colin Gerard Murphy; William Curtin
Journal:  Arch Bone Jt Surg       Date:  2018-11

3.  Uncemented total hip arthroplasty; increased risk of early periprosthetic fracture requiring revision surgery in elderly females.

Authors:  S R Hopman; T S de Windt; J H J van Erp; J E J Bekkers; A de Gast
Journal:  J Orthop       Date:  2021-04-02

4.  Acetabular Liner Dissociation: A Comparative Study of Two Contemporary Uncemented Acetabular Components.

Authors:  David P Gwynne-Jones; Adeel Memon
Journal:  Arthroplast Today       Date:  2020-06-12

5.  Femur Strength is Similar Before and After Iatrogenic Fracture During Total Hip Arthroplasty: A Biomechanical Analysis.

Authors:  Bailey J Ross; Akshar H Patel; J Heath Wilder; John M Weldy; Charles S Dranoff; Matthew J Weintraub; Nathan E Kim; Hao Wang; William F Sherman
Journal:  Arthroplast Today       Date:  2022-04-04

6.  Combining autologous bone marrow buffy coat and angioconductive bioceramic rod grafting with advanced core decompression improves short-term outcomes in early avascular necrosis of the femoral head: a prospective, randomized, comparative study.

Authors:  Qingtian Li; Weihong Liao; Guangtao Fu; Junxing Liao; Ruiying Zhang; Mengyuan Li; Yuhui Yang; Yuanchen Ma; Minghao Zheng; Qiujian Zheng
Journal:  Stem Cell Res Ther       Date:  2021-06-19       Impact factor: 6.832

7.  Observed effect of femoral component undersizing and a collarless design in the development of radiolucent lines in cementless total hip arthroplasty.

Authors:  Paul Magill; Janet Hill; Seamus O'Brien; Michael Stevenson; Alain Machenaud; David Beverland
Journal:  Arthroplast Today       Date:  2020-01-06

8.  Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up.

Authors:  Oskari A Pakarinen; Perttu S Neuvonen; Aleksi R P Reito; Antti P Eskelinen
Journal:  Acta Orthop       Date:  2020-04-01       Impact factor: 3.717

9.  Does Proximal Femoral Morphology Impact Morbidity and Mortality? A Cohort Study of Uncemented Hemiarthroplasties in the Treatment of Femoral Neck Fractures.

Authors:  Evelyn P Murphy; Christopher Fenelon; Adrian Cassar-Gheiti; Padhraig O'Loughlin; William Curtin; Colin G Murphy
Journal:  Arthroplast Today       Date:  2021-07-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.