| Literature DB >> 32089594 |
Jayant N Palaskar1, Nikhil Joshi1, Pooja M Shah1, Poorva Gullapalli1, Vineet Vinay2.
Abstract
AIM: The aim of this study is to assess the influence of different implant placement techniques to improve primary implant stability (PIS) in the low-density bone.Entities:
Keywords: Bone density; guided drilling; osseointegration; primary implant stability
Year: 2020 PMID: 32089594 PMCID: PMC7008617 DOI: 10.4103/jips.jips_244_18
Source DB: PubMed Journal: J Indian Prosthodont Soc ISSN: 0972-4052
Figure 1Selection of articles
Studies on primary implant stability
| Author and year | Implant and manufacturer | Implant size | Implant number | Region | Bone type | Technique of evaluation of stability | Result of evaluation | Insertion technique | Other findings |
|---|---|---|---|---|---|---|---|---|---|
| Pozzi | 57 nobel speedy replace implants and 24 nobel speedy groovy (PS1) | Not specified | 29 axial and 42 straight | Atrophied maxillary posterior | Not specified | IT | 40-50 Ncm | Underprepared osteotomy | |
| Alghamdi | Straumann (standard plus) (PS2) | 4.1 mm × 12 mm | 26 | Posterior maxilla and mandible | Lekholm and Zarb 3 and 4 according to radiographic assessment and drilling resistance | IT and RFA | IT - 35.19±4.79 ISQ - 68.58±4.81 | Undersized drilling | Comparison of standard osteotomy in normal bone and undersized osteotomy in bone with low bone mineral density |
| Herekar | Nobel replace select (Nobel Biocare) and GSIII/TSIII (Osstem) | Not specified | 20 | Not specified | D4 | RFA | 60±4.15 | Standard drilling protocol | Comparison of primary and secondary ISQ of the different types of bone |
| Alsaadi | Mark III TiUnitet implants (Branemark systems, Nobel Biocare, (PS3) | Not specified | 47 | Not specified | Lekholm and Zarb 4 | Periotest | 3.28 - crestal, 5.49 - middle, 8.38 - Apical | Standard drilling protocol | |
| Makary | Tapered Screw-Vent MTX, Zimmer Dental | 4.1 or 4.7 mm diameter | 9 | D4 | IT | 40.22 Ncm | Standard drilling protocol | Trephine drill used initially to obtain biopsy to determine the bone type | |
| Anitua | BTI implants (BTI, Vitoria, Spain) | 8.5 mm-long | Lekholm and Zarb 4 | IT | 34.84±2.38 Ncm | Socket under-preparation by 1 mm | |||
| O’Sullivan 2004[ | Branemark Standard implants (Nobel Biocare AB, Gothenburg, Sweden), Branemark SystemR Mk IV implant (Nobel Biocare AB) | Not specified | 9 (4 Standard implant and 5 Mk IV implant) | Not specified | Lekholm and Zarb 4 | IT RFA | 14.0 and 12.3 Ncm respectively 5.6 and 5.86 KHz | IT increases due to inherent cutting property of implant | Inducing greater stresses in cortical bone |
IT: Insertion torque, ISQ: Implant stability quotient, RFA: Resonance frequency analysis