Literature DB >> 22117707

Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study.

Hamdan Alghamdi1, Pradeep S Anand, Sukumaran Anil.   

Abstract

PURPOSE: Achieving primary implant stability in areas with poor bone density is often challenging to the clinician. Previous research has suggested that modified surgical protocols might be beneficial in such situations. The objective of the present clinical study was to evaluate the survival rate of implants placed using undersized implant site preparation in areas with poor bone density.
MATERIALS AND METHODS: A total of 52 implants were placed in 29 patients. Of the 52 implants, 26 were surgically placed according to the standard drilling protocol (control group) and 26 were placed in low-density bone using an adapted bone drilling method (test group). The maximum insertion torque values and resonance frequency analysis measurements were also recorded. All implants were examined clinically and radiographically at follow-up visits during the study period. Oral hygiene status, bleeding on probing, peri-implant probing depth, and implant survival rate were assessed.
RESULTS: According to the survival criteria used in the present study, no failure was recorded, and the overall survival rate was 100% for both groups after 12 months. The mean probing depth was 2.75 ± 0.75 mm in the test group and 2.87 ± 0.79 mm in the control group. The mean insertion torque value was 35.19 ± 4.79 Ncm in the test group and 34.62 ± 5.82 Ncm in the control group. The resonance frequency analysis value was 68.58 ± 4.81 implant stability quotient and 66.69 ± 5.41 implant stability quotient in the test and control groups, respectively. The observed differences were not statistically significant (P > .05).
CONCLUSIONS: The results of the present study suggest that placement of implants by an adapted drilling technique in sites with poor bone density is beneficial in enhancing primary implant stability and improving the implant survival rate.
Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22117707     DOI: 10.1016/j.joms.2011.08.007

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  18 in total

1.  Implant stability in different techniques of surgical sites preparation: an in vitro study.

Authors:  C Rastelli; G Falisi; R Gatto; M Galli; E Saccone; M Severino; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

2.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

Review 3.  Osseodensification -- A systematic review and qualitative analysis of published literature.

Authors:  Ninad Milind Padhye; Ashvini Mukul Padhye; Neel B Bhatavadekar
Journal:  J Oral Biol Craniofac Res       Date:  2019-11-02

4.  Implant-supported fixed prostheses in a Patient with Osteogenesis Imperfecta: A 4-year follow-up.

Authors:  Mario Caicedo-Rubio; Elvira Ferrés-Amat; Eduard Ferrés-Padró
Journal:  J Clin Exp Dent       Date:  2017-12-01

5.  Drilling dimension effects in early stages of osseointegration and implant stability in a canine model.

Authors:  Felipe-Eduardo Baires-Campos; Ryo Jimbo; Estevam-Augusto Bonfante; Maiolino-Thomaz Fonseca-Oliveira; Camila Moura; Darceny Zanetta-Barbosa; Paulo-Guilherme Coelho
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-07-01

Review 6.  Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review.

Authors:  Rola Muhammed Shadid; Nasrin Rushdi Sadaqah; Sahar Abdo Othman
Journal:  Int J Dent       Date:  2014-07-07

7.  The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study.

Authors:  G Falisi; M Severino; C Rastelli; S Bernardi; S Caruso; M Galli; L Lamazza; C Di Paolo
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-03-01

8.  The effect of implant length and diameter on the primary stability in different bone types.

Authors:  Hamidreza Barikani; Shadab Rashtak; Soolmaz Akbari; Samareh Badri; Niloufar Daneshparvar; Amirreza Rokn
Journal:  J Dent (Tehran)       Date:  2013-09-30

9.  New Osseodensification Implant Site Preparation Method to Increase Bone Density in Low-Density Bone: In Vivo Evaluation in Sheep.

Authors:  Paolo Trisi; Marco Berardini; Antonello Falco; Michele Podaliri Vulpiani
Journal:  Implant Dent       Date:  2016-02       Impact factor: 2.454

10.  Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.

Authors:  Domenico Baldi; Teresa Lombardi; Jacopo Colombo; Gabriele Cervino; Giuseppe Perinetti; Roberto Di Lenarda; Claudio Stacchi
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.