Literature DB >> 19681964

Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets.

Murat Cavit Cehreli1, Ali Murat Kökat, Ayhan Comert, Murat Akkocaoğlu, Ibrahim Tekdemir, Kivanç Akça.   

Abstract

OBJECTIVE: To compare the primary stability of implants placed in conventional and osteotome sites and to evaluate the level of correlation between cutting torque measurements, resonance frequency analysis (RFA), and bone density.
MATERIALS AND METHODS: Eight human femoral heads were scanned with computed tomography for bone density measurements as Hounsfield units (HU), and individualized computed tomography-based surgical stents were prepared for placement of implants. Five implant sockets were prepared in each collum (CoF), caput (CaF), and trochanter (Tr-MM) section of the femoral heads using the conventional drilling technique or by a combination of drilling and use of an osteotome. Cutting-torque values (CTV) of the implants were measured by a manual torque wrench, followed by determination of implant stability quotients (ISQ) by RFA.
RESULTS: The CTVs of implants were similar in the conventional group, but different in the osteotome group (P<0.05). There was a general tendency toward achieving higher CTV and ISQ values in CoF than CaF and Tr-MM (P<0.05), and measurements in CaF and Tr-MM were comparable (P>0.05). The mean HU of sites were similar, although CoF had higher HU values (P>0.05). CTV of implants in CaF and Tr-MM and ISQ values in CoF in the conventional groups were higher than those in the osteotome groups (P<0.05). The correlation between CTV and HU in Tr-MM was significant in the osteotome group, although no other correlations between CTV, ISQ, and HU could be detected (P>0.025).
CONCLUSIONS: Conventional placement led to higher implant stability than the drilling and osteotome technique used in the study. No correlation could be found between CTV, RFA, and bone density.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19681964     DOI: 10.1111/j.1600-0501.2009.01758.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  14 in total

1.  Effects of Condensation on Peri-implant Bone Density and Remodeling.

Authors:  L Wang; Y Wu; K C Perez; S Hyman; J B Brunski; U Tulu; C Bao; B Salmon; J A Helms
Journal:  J Dent Res       Date:  2017-01-03       Impact factor: 6.116

2.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

3.  Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study.

Authors:  J Barberá-Millán; C Larrazábal-Morón; J-J Enciso-Ripoll; E Pérez-Pevida; D Chávarri-Prado; M-D Gómez-Adrián
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2021-05-01

4.  Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value.

Authors:  Hong-Gi Yoon; Seong-Joo Heo; Jai-Young Koak; Seong-Kyun Kim; Su-Young Lee
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

5.  The effect of the thread depth on the mechanical properties of the dental implant.

Authors:  Sun-Young Lee; Sung-Jun Kim; Hyun-Wook An; Hyun-Seung Kim; Dong-Guk Ha; Kyung-Ho Ryo; Kwang-Bum Park
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

Review 6.  Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review.

Authors:  Rola Muhammed Shadid; Nasrin Rushdi Sadaqah; Sahar Abdo Othman
Journal:  Int J Dent       Date:  2014-07-07

7.  A Comparison between the Implant Stability Quotient and the Fractal Dimension of Alveolar Bone at the Implant Site.

Authors:  Tomasz Kulczyk; Agata Czajka-Jakubowska; Agnieszka Przystańska
Journal:  Biomed Res Int       Date:  2018-10-15       Impact factor: 3.411

8.  Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size.

Authors:  Vasilena Ivanova; Ivan Chenchev; Stefan Zlatev; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2021-06-30       Impact factor: 3.390

9.  An ex vivo model in human femoral heads for histopathological study and resonance frequency analysis of dental implant primary stability.

Authors:  Pedro Hernández-Cortés; Alberto Monje; Pablo Galindo-Moreno; Andrés Catena; Inmaculada Ortega-Oller; José Salas-Pérez; Francisco Mesa; Rafael Gómez-Sánchez; Mariano Aguilar; David Aguilar; Francisco O'Valle
Journal:  Biomed Res Int       Date:  2014-06-04       Impact factor: 3.411

10.  Comparison of Implant Stability Using Resonance Frequency Analysis: Osteotome Versus Conventional Drilling.

Authors:  Rokhsareh Sadeghi; Amir Reza Rokn; Asghar Miremadi
Journal:  J Dent (Tehran)       Date:  2015-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.