Literature DB >> 2002427

The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis.

R A Jaffin, C L Berman.   

Abstract

The predictability of branemark implants has been well documented. High success rates in the maxilla and mandible in fully and partially edentulous patients can be expected. A host of factors may be attributed to the etiology of fixture loss. However, the quality of bone stands out as the single greatest determinant in fixture loss. Types I, II, and III bone offer good strength. Type IV bone has a thin cortex and poor medullary strength with low trabecular density. Ninety percent of 1,054 implants placed were in Types I, II, and III bone. Only 3% of these fixtures were lost; of the 10% of the fixtures placed in Type IV bone, 35% failed. Presurgical determination of Type IV bone may be one method to decrease implant failure.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2002427     DOI: 10.1902/jop.1991.62.1.2

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  85 in total

Review 1.  Role of implant diameter on long-term survival of dental implants placed in posterior maxilla: a systematic review.

Authors:  Fawad Javed; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-11-01       Impact factor: 3.573

Review 2.  Periodontal surgery in furcation-involved maxillary molars revisited--an introduction of guidelines for comprehensive treatment.

Authors:  Clemens Walter; Roland Weiger; Nicola Ursula Zitzmann
Journal:  Clin Oral Investig       Date:  2010-06-23       Impact factor: 3.573

Review 3.  Efficacy of parathyroid hormone supplementation on the osseointegration of implants: a systematic review.

Authors:  Fawad Javed; Mohammad D Al Amri; Sergio Varela Kellesarian; Abdulaziz A Al-Kheraif; Fahim Vohra; José Luis Calvo-Guirado; Hans Malmstrom; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

4.  Comparative study of axial and femoral bone mineral density and parameters of mandibular bone quality in patients receiving dental implants.

Authors:  M A L Amorim; L Takayama; V Jorgetti; R M R Pereira
Journal:  Osteoporos Int       Date:  2006-06-24       Impact factor: 4.507

Review 5.  Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives.

Authors:  Fabio Variola; John B Brunski; Giovanna Orsini; Paulo Tambasco de Oliveira; Rima Wazen; Antonio Nanci
Journal:  Nanoscale       Date:  2010-10-26       Impact factor: 7.790

Review 6.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

7.  Implant stability evaluation by resonance frequency analysis in the fit lock technique. A clinical study.

Authors:  Giovanni Falisi; Massimo Galli; Pedro Vittorini Velasquez; Juan Carlos Gallegos Rivera; Carlo Di Paolo
Journal:  Ann Stomatol (Roma)       Date:  2013-06-25

8.  Pterygomaxillary implants: a graftless solution to deficient maxillary bone.

Authors:  G N Anandakrishna; Girish Rao
Journal:  J Indian Prosthodont Soc       Date:  2012-06-12

9.  Histomorphometric evaluation of implants coated with enamel or dentine derived fluoride-substituted apatite.

Authors:  Mehmet Kürkcü; Mehmet Emre Benlidayi; Serhat Ozsoy; Lütfiye Sevgi Ozyeğin; Faik Nuzhet Oktar; Cem Kurtoğlu
Journal:  J Mater Sci Mater Med       Date:  2007-06-19       Impact factor: 3.896

10.  Implants coated with bioactive glass by CO2-laser, an in vivo study.

Authors:  N Moritz; S Rossi; E Vedel; T Tirri; H Ylänen; H Aro; T Närhi
Journal:  J Mater Sci Mater Med       Date:  2004-07       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.