BACKGROUND: Computed tomography (CT) scans are routinely performed in positron emission tomography (PET) and single photon emission computed tomography (SPECT) examinations globally, yet few surveys have been conducted to gather national diagnostic reference level (NDRL) data for CT radiation doses in positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT). In this first Nordic-wide study of CT doses in hybrid imaging, Nordic NDRL CT doses are suggested for PET/CT and SPECT/CT examinations specific to the clinical purpose of CT, and the scope for optimisation is evaluated. Data on hybrid imaging CT exposures and clinical purpose of CT were gathered for 5 PET/CT and 8 SPECT/CT examinations via designed booklet. For each included dataset for a given facility and scanner type, the computed tomography dose index by volume (CTDIvol) and dose length product (DLP) was interpolated for a 75-kg person (referred to as CTDIvol,75kg and DLP75kg). Suggested NDRL (75th percentile) and achievable doses (50th percentile) were determined for CTDIvol,75kg and DLP75kg according to clinical purpose of CT. Differences in maximum and minimum doses (derived for a 75-kg patient) between facilities were also calculated for each examination and clinical purpose.Entities:
Keywords: Computed tomography; Diagnostic reference levels; Dosimetry; Hybrid imaging; PET/CT; SPECT/CT
Year: 2019 PMID: 31845047 PMCID: PMC6915162 DOI: 10.1186/s40658-019-0266-7
Source DB: PubMed Journal: EJNMMI Phys ISSN: 2197-7364
Fig. 1Boxplot showing spread in DLP75kg data for reliable PET/CT and SPECT/CT datasets (Mean DLP data (not weight-derived) normalised to a 16-cm CTDI phantom are given for PET/CT brain)
Suggested NDRL and achievable doses for PET/CT and SPECT/CT examinations according to clinical purpose (Mean DLP data (not weight-derived) normalised to a 16-cm CTDI phantom are given for PET/CT brain; NDRL and achievable doses are not presented for PET/CT oncology diagnostic CT scans as standalone diagnostic NDRLs should be used for comparison)
| Examination | Clinical purpose | Suggested NDRL (75th percentile) | Achievable dose (50th percentile) | ||
|---|---|---|---|---|---|
| CTDIvol (mGy) | DLP (mGy.cm) | CTDIvol (mGy) | DLP (mGy.cm) | ||
| PET/CT oncology | Localisation/characterisation | 2.9 | 310 | 2.6 | 258 |
| PET/CT infection/inflammation | Localisation/characterisation | 3.5 | 431 | 2.5 | 326 |
| PET/CT brain | AC only | 6.4 | 148 | 5.7 | 104 |
| PET/CT and SPECT/CT cardiac | AC only | 2.2 | 53 | 1.6 | 35 |
| SPECT/CT lung | Localisation/characterisation | 2.9 | 117 | 2.5 | 89 |
| SPECT/CT bone (main body) | Localisation/characterisation | 4.0 | 215 | 2.0 | 108 |
| SPECT/CT parathyroid | Localisation/characterisation | 5.7 | 199 | 3.5 | 131 |
Summary data for CTDIvol, 75kg, DLP75kg, and scan length, for all examinations and clinical purposes (Mean DLP data (not weight-derived) normalised to a 16cm CTDI phantom are given for PET/CT brain)
| Examination | Clinical purpose of CT | Number of datasets | CTDIvol,75kg (mGy) | DLP75kg (mGy.cm) | Scan length (cm) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mean | Median | Min | Max | Max/min | Mean | Median | Min | Max | Max/min | Mean | Median | Min | Max | Max/min | |||
| PET/CT oncology | AC only | 6 | 1.4 | 1.4 | 0.3 | 2.4 | 8.0 | 141 | 136 | 29 | 263 | 9.0 | 102 | 103 | 87 | 114 | 1.3 |
| L/C | 15 | 2.7 | 2.6 | 1.8 | 4.9 | 2.7 | 270 | 258 | 169 | 498 | 2.9 | 99 | 99 | 80 | 116 | 1.5 | |
| Diagnostica | 11 | 9.9 | 8.5 | 6.4 | 14.8 | 2.3 | 963 | 825 | 683 | 1445 | 2.1 | 100 | 98 | 85 | 124 | 1.5 | |
| PET/CT infection/inflammation | AC only | 4 | 1.8 | 1.4 | 0.3 | 4.4 | 14.7 | 194 | 131 | 27 | 488 | 18.1 | 101 | 98 | 95 | 113 | 1.2 |
| L/C | 13 | 3.3 | 2.5 | 1.8 | 7.0 | 3.9 | 346 | 326 | 169 | 619 | 3.7 | 110 | 104 | 89 | 167 | 1.9 | |
| Diagnostic | 1 | 8.5 | - | - | - | - | 766 | - | - | - | - | 90 | - | - | - | - | |
| PET/CT brain | AC only | 11 | 4.2 | 5.7 | 0.5 | 8.5 | 17.0 | 94 | 104 | 13 | 196 | 15.0 | 22 | 23 | 17 | 25 | 1.5 |
| L/C | 9 | 15.0 | 10.7 | 3.1 | 66.9 | 21.6 | 302 | 211 | 71 | 1194 | 16.8 | 22 | 23 | 18 | 25 | 1.4 | |
| Diagnostic | 1 | 45.8 | - | - | - | - | 1068 | - | - | - | - | 23 | - | - | - | - | |
| PET/CT and SPECT/CT cardiac | AC only | 30 | 2.1 | 1.6 | 0.4 | 7.1 | 17.8 | 40 | 35 | 5 | 98 | 19.6 | 23 | 23 | 14 | 33 | 2.4 |
| L/C | 7 | 2.7 | 1.9 | 1.3 | 8.0 | 6.2 | 67 | 39 | 28 | 157 | 5.6 | 20 | 20 | 19 | 21 | 1.1 | |
| SPECT/CT lung | AC only | 2 | 5.7 | 5.7 | 0.4 | 11 | 27.5 | 185 | 185 | 13 | 356 | 27.4 | 34 | 34 | 32 | 36 | 1.1 |
| L/C | 12 | 2.6 | 2.5 | 1.1 | 5.6 | 5.1 | 93 | 89 | 42 | 177 | 4.2 | 36 | 35 | 30 | 43 | 1.5 | |
| SPECT/CT bone | AC only | 1 | 2.1 | - | - | - | - | 235 | - | - | - | - | 111 | - | - | - | - |
| L/C | 30 | 2.8 | 2.0 | 1.1 | 7.3 | 6.6 | 153 | 108 | 40 | 402 | 10.0 | 55 | 43 | 37 | 114 | 3.1 | |
| Diagnostic | 1 | 2.34 | - | - | - | - | 255 | - | - | - | - | 69 | - | - | - | - | |
| SPECT/CT parathyroid | AC only | 1 | 3.2 | - | - | - | - | 100 | - | - | - | - | 32 | - | - | - | - |
| L/C | 13 | 4.1 | 3.5 | 1.5 | 10.6 | 7.1 | 150 | 131 | 37 | 292 | 7.8 | 40 | 40 | 24 | 62 | 2.6 | |
| Diagnostic | 1 | 15.6 | - | - | - | - | 365 | - | - | - | - | 24 | - | - | - | - | |
aNDRL and achievable doses are not presented for PET/CT oncology diagnostic CT scans as standalone diagnostic NDRLs should be used for comparison
Fig. 2Distribution of DLP75kg according to system number and clinical purpose for PET/CT oncology whole body (Data submissions from a system for more than one clinical purpose are labelled with a letter suffix) (a), PET/CT infection/inflammation (b), PET/CT brain (Mean DLP data (not weight-derived) normalised to a 16-cm CTDI phantom are given for PET/CT brain; Data submissions from a system for more than one clinical purpose are labelled with a letter suffix) (c). SPECT/CT lung (d)
Comparison of key protocol settings contributing to dose differences between maximum and minimum DLP75kg systems
| Examination | Clinical purpose of CT | Max/min DLP75kg | Max or min DLP75kg protocol | Scan length (cm) | Summary of main protocol differences contributing to variation in DLP75kg |
|---|---|---|---|---|---|
| PET/CT brain | Localisation/characterisation | 16.8 | Max | 18 | Exceptionally high effective mAs for localisation/characterisation (images originally intended for diagnostic use) |
| Min | 23 | ||||
| PET/CT and SPECT/CT cardiac | AC only | 19.6 | Max | 29 | High effective mAs for AC only; long scan length |
| Min | 16 | Attempted to optimise for AC only with low effective mAs (low mA, high pitch) and low kV; use of IR | |||
| SPECT/CT lung | AC only | 27.4 | Max | 32 | High kV; high effective mAs for AC only |
| Min | 36 | Attempted to optimise for AC only with low effective mAs (low mA, high pitch); use of IR | |||
| Localisation/characterisation | 4.2 | Max | 32 | Higher kV and effective mAs than minimum DLP75kg protocol | |
| Min | 33 | Low kV and effective mAs | |||
| SPECT/CT bone | Localisation/characterisation | 10.0 | Max | 106 | Three times greater scan length, higher kV and effective mAs than minimum DLP75kg protocol |
| Min | 37 | Use of IR | |||
| SPECT/CT parathyroid | Localisation/characterisation | 7.8 | Max | 28 | Much higher effective mAs (but lower kV) than minimum DLP75kg protocol |
| Min | 24 |