| Literature DB >> 26908992 |
Hyun Woo Kwon1, Jong Phil Kim2, Hong Jae Lee2, Jin Chul Paeng3, Jae Sung Lee2, Gi Jeong Cheon3, Dong Soo Lee4, June-Key Chung3, Keon Wook Kang3.
Abstract
The purpose of this study was to estimate average radiation exposure from (18)F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) examinations and to analyze possible factors affecting the radiation dose. A nation-wide questionnaire survey was conducted involving all institutions that operate PET/CT scanners in Korea. From the response, radiation doses from injected FDG and CT examination were calculated. A total of 105 PET/CT scanners in 73 institutions were included in the analysis (response rate of 62.4%). The average FDG injected activity was 310 ± 77 MBq and 5.11 ± 1.19 MBq/kg. The average effective dose from FDG was estimated to be 5.89 ± 1.46 mSv. The average CT dose index and dose-length product were 4.60 ± 2.47 mGy and 429.2 ± 227.6 mGy∙cm, which corresponded to 6.26 ± 3.06 mSv. The radiation doses from FDG and CT were significantly lower in case of newer scanners than older ones (P < 0.001). Advanced PET technologies such as time-of-flight acquisition and point-spread function recovery were also related to low radiation dose (P < 0.001). In conclusion, the average radiation dose from FDG PET/CT is estimated to be 12.2 mSv. The radiation dose from FDG PET/CT is reduced with more recent scanners equipped with image-enhancing algorithms.Entities:
Keywords: Dose Reference Level; FDG PET/CT; National Survey; Radiation Exposure
Mesh:
Substances:
Year: 2016 PMID: 26908992 PMCID: PMC4756346 DOI: 10.3346/jkms.2016.31.S1.S69
Source DB: PubMed Journal: J Korean Med Sci ISSN: 1011-8934 Impact factor: 2.153
Surveyed items and questions in the questionnaire
| Part | Surveyed item or question |
|---|---|
| Equipment | Model name, manufacturer, installation date |
| Image protocol of each scanner | Is TOF acquisition used in PET acquisition? |
| Is PSF-recovery algorithm used in PET acquisition? | |
| Is FDG activity adjusted by body weight or fixed? | |
| Is there any other consideration point in activity determination? | |
| What is injected FDG activity? | |
| How many times of CT scan are acquired? | |
| Is contrast agent is used in CT acquisition? | |
| Is CT dose is reported routinely? | |
| Is dose-reduction software is used in CT imaging? | |
| What are CT acquisition parameters (kVp, mA, rotation time, slice thickness, pitch factor)? | |
| Dosimetry of real patients | Age, sex, body weight, scan coverage, injected FDG activity, CT factors (total mAs, CTDIvol, DLP) |
Fig. 1Geometric distribution of the 73 institutions included in this survey.
Characteristics of the dedicated PET/CT scanners included in the survey
| Characteristics | No. |
|---|---|
| Manufacturer and model (No.) | |
| GE | 45 |
| Discovery 600 (5), 690 (8) 710 (7) ST (4), STE (12), STE8 (1), STE16 (6), VCT (2) | |
| Philips | 18 |
| GXL6 (1), 16POWER (1), TF (4), TF16 (4), TF64 (8) | |
| Siemens | 41 |
| DUO (2), TruePoint (1), TruePoint2 (2), TruePoint6 (4), TruePoint16 (2), TruePoint40 (12), TruePoint64 (1), mCT20 (2), mCT40 (1), mCT 64 (5), mCT128 (6), mCT X4R (1), mCT FLOW (2) | |
| No information | 1 |
| Scintillator crystal of PET scanners | |
| BGO | 30 |
| GSO | 3 |
| LBS | 15 |
| LSO | 42 |
| LYSO | 14 |
| No information | 1 |
| Installation yr | |
| 2000–2005 | 13 |
| 2006–2010 | 50 |
| 2011–2015 | 41 |
| No information | 1 |
| Total | 105 |
BGO, bismuth germanium oxide; CT, computed tomography; GSO, cerium-doped gadolinium oxyorthosilicate; LBS, lutetium based scintillators (not otherwise specified); LSO, cerium-doped lutetium oxyorthosilicate; LYSO, cerium-doped lutetium-yttrium oxyorthosilicate; PET, positron emission tomography.
Fig. 2Distribution of injected FDG activity and CTDIvol values of CT examinations in each institution. (A) Median value of injected FDG activity is 5.00 MBq/kg (25th–75th percentile, 4.24–5.62 MBq/kg; gray box). (B) Median value of CTDIvol is 4.10 mGy (25th–75th percentile, 2.80–5.96 mGy; gray box).
Fig. 3Distribution of injected FDG activity (A), CTDIvol (B), and DLP (C) of each PET/CT examination.
Radiation dose of FDG PET/CT according to installation year
| Installation yr | No. | FDG activity, | CTDIvol, | DLP, |
|---|---|---|---|---|
| 2000-2005 | 13 | 6.10 ± 1.19 | 6.04 ± 2.58 | 514.5 ± 246.5 |
| 2006-2010 | 50 | 5.30 ± 1.22 | 4.87 ± 2.85 | 460.7 ± 241.2 |
| 2011-2015 | 42 | 4.60 ± 0.85 | 3.95 ± 1.97 | 369.6 ± 185.4 |
| < 0.001 | < 0.001 | < 0.001 |
CTDIvol, volume computed tomography dose index; DLP, dose-length product; FDG, F-18 fluorodeoxyglucose.