Literature DB >> 29463428

Swiss survey on hybrid imaging CTs doses in Nuclear Medicine and proposed national dose reference levels.

Thiago V M Lima1, Silvano Gnesin2, Nick Ryckx2, Klaus Strobel3, Nicolas Stritt4, Reto Linder4.   

Abstract

A multidisciplinary working group led by the Swiss Federal Office of Public Health was formed to plan and perform a nationwide survey of patient radiation exposure from computed tomography (CT) in hybrid devices across Nuclear Medicine departments. The survey included 16 departments (of which 5 were university hospitals) and the submitted responses included 10,673 entries for the 33 different protocols proposed (11 in PET and 22 in SPECT). The working group determined the selection and exclusion criteria applied to the analysis. This work presents the survey preparation and data analysis including the exclusion criteria used. The results are used to inform recommendations for National Diagnostic Reference Levels (DRL) for CT procedures in Nuclear Medicine in Switzerland. Of the 33 protocols initially proposed, 10 protocols for both PET and SPECT modalities were retained after exclusion criteria and thresholds were applied. The results obtained in terms of volume-weighted computed tomography dose index (CTDIvol) and dose length product (DLP) have been put forward as recommendations for national Diagnostic Reference Levels for protocols in hybrid imaging devices in Nuclear Medicine in Switzerland and will be published by the Federal Office of Public Health.
Copyright © 2018. Published by Elsevier GmbH.

Entities:  

Keywords:  CT doses; DRL; Hybrid devices; National survey; Nuclear Medicine; Patient exposure

Mesh:

Year:  2018        PMID: 29463428     DOI: 10.1016/j.zemedi.2018.01.005

Source DB:  PubMed          Journal:  Z Med Phys        ISSN: 0939-3889            Impact factor:   4.820


  2 in total

1.  A Nordic survey of CT doses in hybrid PET/CT and SPECT/CT examinations.

Authors:  Natalie A Bebbington; Bryan T Haddock; Henrik Bertilsson; Eero Hippeläinen; Ellen M Husby; Virpi I Tunninen; Marcus Söderberg
Journal:  EJNMMI Phys       Date:  2019-12-16

2.  National Diagnostic Reference Level (DRL) for nuclear medicine computed tomography-positron emission tomography hybrid imaging studies for kuwait population: second phase dose audit-2019.

Authors:  Michael Masoomi; Iman Al-Shammeri; Latifah Al-Kandari; Hany Elrahman; Jehan Al-Shammeri
Journal:  BJR Open       Date:  2021-11-24
  2 in total