Satheesh B Haralur1, Salem Mohammed Alharthi2, Saeed Aied Abohasel3, Khalid Mohammed Alqahtani4.
Abstract
Blood-saliva contamination negatively affects the bonding potential of adhesive agents. The study aimed to assess the effect of various cleaning protocols on micro-shear bond strength (μSBS) between blood-saliva-contaminated post-etched dentin and composite resin in total-etch and self-etch adhesives. The cleaning methods tested were water rinsing, 37.5% phosphoric acid (H3PO4) re-etching, 6% sodium hypochlorite (NaoCl), 2% chlorhexidine gluconate (CXG), isopropyl alcohol (IPA), and pumice. Nono-hybrid composite cylinders with a 3-mm diameter and 2-mm height were directly cured over the dentin substrate, stored for 24 h, and subjected to 12,000 thermocycles. The shear force was exerted with a 200-μm knife-edged chisel-shaped head from a universal testing machine. The type of failure was assessed with stereomicroscope magnified images. The obtained data were evaluated by Kruskal-Wallis and Mann-Whitney U post-hoc tests. Water-rinsed contaminated dentin surfaces showed substantially reduced μSBS in the total etch from 25.93 to 20.29 Mpa and the corresponding values for the one-step self-etch adhesive were 10.10 to 8.8. Re-etching with 37.5% H3Po4 resulted in a recovery of bonding potential in both total-etch (24.58 Mpa) and self-etch adhesive (9.23 Mpa). Alternately, NaoCl and pumice cleaning showed promising results for the total-etch (23.51 Mpa) and self-etch (7.79 Mpa).Entities:
Keywords: blood–saliva contamination; dentin bonding agents; dentin decontamination method; micro-shear bond strength
Year: 2019 PMID: 31683858 PMCID: PMC6956069 DOI: 10.3390/healthcare7040128
Source DB: PubMed Journal: Healthcare (Basel) ISSN: 2227-9032
Figure 1Embedded teeth sample in acrylic resin.
Figure 2Flowchart of the method: Sample distribution.
Description of the surface treatment and bonding procedure for each subgroup as follows.
| Group | Total-Etch | Self-Etch |
|---|---|---|
| No contamination | 37.5% phosphoric acid gel (Kerr, Karlsruhe, Germany) 15 s. Water rinse 10 s, gentle air dry. Apply bonding agent (Tetric-N Bond total etch, Ivoclar Vivadent AG, Schaan, Liechtenstein). Brush the material gently into the dentin for 10 s, air dry and light cure 10 s (LED unit (700 mW/cm2) | Applied one layer of one bottle self-etch bonding agent (G-ænial, GC America Inc. St, Alsip, IL, USA) left undisturbed 10 s, dry thoroughly for 5 s, light cure 10 s with LED unit (700 mW/cm2) |
| Contamination water rinse | Contaminated the etched surface with blood/saliva mix for 1 min, water rinsed for 10 s, gently air dried for 5 s, application of bonding agent, composite application | Contaminated the self-etched surface with blood/saliva mix for 1 min, water rinsed for 10 s, Gently air dried for 5 s. Re-application of adhesive |
| Contamination, water wash, Re-etch | Blood/saliva contamination of etched surface, water rinsed, air dried, subsequently re-etched with 37.5% H3PO4 for 10 s, application of bonding agent | Contaminated the self-etched surface with blood/saliva mix, water rinsed, air dried, re-etched with 37.5% H3PO4 for 10 s, application of self-etch bonding agent |
| Contamination Naocl clean, water wash | Blood/saliva contamination of etched surface, 6% sodium hypochlorite (Vita dental products, Racine, WI, USA) applied with micro brush for 15 s, water rinse for 10 s, application of bonding agent | Contaminated the self-etched surface with blood/saliva mix, 6% sodium hypochlorite applied with micro brush for 15 s, water rinse for 10 s, re-apply self-etch bonding |
| Contamination, water wash CHG disinfection | Blood/saliva contamination of etched surface, water rinse for 10 s, 2% chlorhexidine gluconate (Consepsis, Ultradent INC, South Jordan, UT, USA) rub the area for 10 s, air dried and bonding agent application | Contaminated the self-etched surface with blood/saliva mix, water rinse for 10 s, 2% chlorhexidine gluconate (Consepsis, Ultradent INC, South Jordan, UT, USA) rub the area for 10 s, air dried and re-apply self-etch bonding |
| Contamination, water wash, isopropyl alcohol swabs | Blood/saliva contamination of etched surface, water rinse for 10 s, rub the surface with 70% isopropyl alcohol swabs (sterie swab), for 10 s, bonding agent application | Contaminated the self-etched surface with blood/saliva mix, water rinse for 10 s, rub the surface with isopropyl alcohol swabs for 10 s, re-apply self–etch bonding |
| Contamination, cleaning with pumice, alcohol swabs | Blood/saliva contamination of etched surface, water rinse, rub the area with un-fluoridated pumice for 15 s at 2000 rpm prophy brush, water rinse, bond agent application | Blood/saliva contamination of etched surface, water rinse, rub the area with un-fluoridated pumice for 15 g, water rinse, re-apply self-etch bonding |
Figure 3Custom-made additional silicone mold to standardize the composite cylinder size and location.
Figure 4Macro shear bond strength evaluation with INSTRON.
Descriptive statistics of the Shear bond strength (Mpa) measured in the different groups.
| Group |
| Total-Etch | Self-Etch |
|---|---|---|---|
| Mean (SD) | Mean (SD) | ||
| No Contamination | 10 | 25.93 (0.96) | 10.10 (0.59) |
| Wash | 10 | 20.29 (1.08) | 8.83 (0.81) |
| Re-Etch | 10 | 24.58 (0.94) | 9.23 (0.83) |
| NaOCl | 10 | 23.25 (1.08) | 7.20 (0.56) |
| CHG | 10 | 14.95 (0.80) | 6.58 (0.45) |
| IPA | 10 | 13.14 (0.86) | 6.25 (0.66) |
| Pumice | 10 | 9.73 (0.83) | 7.79 (0.97) |
NaOCl = sodium hypochlorite, CHG = chlorhexidine gluconate, IPA = isopropyl alcohol.
Kruskal–Wallis analysis on SBS measured on different groups.
| Surface Treatment | Total-Etch Bonding | Self-Etch Bonding | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean Rank | χ2 | df |
| Mean Rank | χ2 | df |
| |
| No Contamn | 63.50 | 65.768 | 6 | 0.000 | 62.30 | 54.33 | 6 | 0.000 |
| Wash | 35.60 | 48.25 | ||||||
| Re-Etch | 55.95 | 52.30 | ||||||
| NaOCl | 46.95 | 26.25 | ||||||
| CHG | 25.00 | 15.35 | ||||||
| IPA | 16.00 | 11.25 | ||||||
| Pumice | 5.50 | 32.80 | ||||||
χ2 = chi-square, significance level is 0.05.
Mann–Whitney post-hoc comparison between the SBS recorded in total-etch groups.
| Group | Wash | Re-Etch | NaOCl | CHG | IPA | Pumice |
|---|---|---|---|---|---|---|
| No Contamn | 0.000 | 0.016 | 0.000 | 0.000 | 0.000 | 0.000 |
| Wash | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
| Re-Etch | 0.006 | 0.000 | 0.000 | 0.000 | ||
| NaOCl | 0.000 | 0.000 | 0.000 | |||
| CHG | 0.001 | 0.000 | ||||
| IPA | 0.000 |
Significance p ≤ 0.05.
Mann–Whitney post-hoc comparison between the SBS recorded in self-etch groups.
| Group | Wash | Re-Etch | NaOCl | CHG | IPA | Pumice |
|---|---|---|---|---|---|---|
| No Contamn | 0.003 | 0.023 | 0.000 | 0.000 | 0.000 | 0.000 |
| Wash | 0.199 | 0.000 | 0.000 | 0.000 | 0.007 | |
| Re-Etch | 0.000 | 0.000 | 0.000 | 0.010 | ||
| NaOCl | 0.021 | 0.002 | 0.173 | |||
| CHG | 0.273 | 0.007 | ||||
| IPA | 0.004 |
Significance p ≤ 0.05.
Fracture mode recorded for each group (in number).
| Group | Total-Etch | One-Step Self-Etch | ||||
|---|---|---|---|---|---|---|
| Adhesive | Cohesive | Mixed | Adhesive | Cohesive | Mixed | |
| No contamination | 0 | 3 | 7 | 1 | 3 | 6 |
| Water Irrigation | 4 | 2 | 4 | 3 | 2 | 5 |
| Re-etch (37% H3PO4) | 1 | 3 | 6 | 2 | 2 | 6 |
| NaOCl | 3 | 1 | 6 | 2 | 1 | 7 |
| CHG | 4 | 1 | 5 | 4 | 2 | 4 |
| IPA | 5 | 1 | 4 | 6 | 0 | 4 |
| Pumice | 6 | 0 | 4 | 2 | 2 | 6 |