Literature DB >> 20533634

Effects of blood contamination on microtensile bond strength to dentin of three self-etch adhesives.

Seok Woo Chang1, Byeong Hoon Cho, Ran Yeob Lim, Seung Hyun Kyung, Dong Sung Park, Tae Seok Oh, Hyun Mi Yoo.   

Abstract

This study evaluated the effects of blood contamination and decontamination methods during different steps of bonding procedures on the microtensile bond strength of two-step self-etch adhesives to dentin. Sixty extracted human molars were ground flat to expose occlusal dentin. The 60 molars were randomly assigned to three groups, each treated with a different two-step self-etch adhesive: Clearfil SE Bond, AdheSE and Tyrian SPE. In turn, these groups were subdivided into five subgroups (n = 20), each treated using different experimental conditions as follows: control group-no contamination; contamination group 1-CG1: primer application/ contamination/primer re-application; contamination group 2-CG2: primer application/contamination/wash/dry/primer re-application; contamination group 3-CG3: primer application/adhesive application/light curing/contamination/ adhesive re-application/light curing; contamina- tion group 4-CG4: primer application/adhesive application/light curing/contamination/wash/ dry/adhesive re-application/light curing. Composite buildup was performed using Z250. After 24 hours of storage in distilled water at 37 degrees C, the bonded specimens were trimmed to an hourglass shape and serially sectioned into slabs with 0.6 mm2 cross-sectional areas. Microtensile bond strengths (MTBS) were assessed for each specimen using a universal testing machine. The data were analyzed by two-way ANOVA followed by a post hoc LSD test. SEM evaluations of the fracture modes were also performed. The contaminated specimens showed lower bond strengths than specimens in the control group (p < 0.05), with the exception of CG1 in the Clearfil SE group and CG2 and CG3 in the Tyrian SPE group. Among the three self-etch adhesives, the Tyrian SPE group exhibited a significantly lower average MTBS compared to the Clearfil SE Bond and AdheSE (p < 0.05) groups. Based on the results of the current study, it was found that blood contamination reduced the MTBS of all three self-etch adhesives to dentin, and water-rinsing was unable to overcome the effects of blood contamination.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20533634     DOI: 10.2341/09-244-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  9 in total

1.  Effect of saliva and blood contamination on the bond strength of self-etching adhesive system- An in vitro study.

Authors:  Madhusudhana Koppolu; Dorasani Gogala; Vinod B Mathew; Venugopal Thangala; Mandava Deepthi; Nalluru Sasidhar
Journal:  J Conserv Dent       Date:  2012-07

2.  Assessment of post-contamination treatments affecting different bonding stages to dentin.

Authors:  Dina Elkassas; Abla Arafa
Journal:  Eur J Dent       Date:  2016 Jul-Sep

3.  Combination Effect of Hemostatic and Disinfecting Agents on Micro-leakage of Restorations Bonded with Different Bonding Systems.

Authors:  Farhadpour H; Sharafeddin F; Akbarian Sc; Azarian B
Journal:  J Dent Biomater       Date:  2016-09

4.  Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood-Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin.

Authors:  Satheesh B Haralur; Salem Mohammed Alharthi; Saeed Aied Abohasel; Khalid Mohammed Alqahtani
Journal:  Healthcare (Basel)       Date:  2019-11-01

5.  Use of rubber dam versus cotton roll isolation on composite resin restorations' survival in primary molars: 2-year results from a non-inferiority clinical trial.

Authors:  Isabel C Olegário; Bruna L P Moro; Tamara K Tedesco; Raiza D Freitas; Ana Laura Pássaro; Jonathan Rafael Garbim; Rodolfo Oliveira; Fausto M Mendes; Daniela Prócida Raggio
Journal:  BMC Oral Health       Date:  2022-10-10       Impact factor: 3.747

6.  Effect of a plant-based hemostatic agent on microleakage of self-etching adhesives.

Authors:  Soley Arslan; Hüseyin Ertaş; Yahya-Orçun Zorba
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-01-01

7.  Evaluation of Shear Bond Strength of Total- and Self-etching Adhesive Systems after Application of Chlorhexidine to Dentin Contaminated with a Hemostatic Agent.

Authors:  Farahnaz Sharafeddin; Hajar Farhadpour
Journal:  J Dent (Shiraz)       Date:  2015-09

8.  Do blood contamination and haemostatic agents affect microtensile bond strength of dual cured resin cement to dentin?

Authors:  Kerem Kilic; Soley Arslan; Goknil Alkan Demetoglu; Gokmen Zararsiz; Bulent Kesim
Journal:  J Appl Oral Sci       Date:  2013 Jan-Feb       Impact factor: 2.698

9.  Effect of rinsing time and surface contamination on the bond strength of silorane-based and dimethacrylate-based composites to enamel.

Authors:  Farnoosh Fallahzadeh; Mohammad Atai; Shirin Ghasemi; Ailin Mahdkhah
Journal:  J Clin Exp Dent       Date:  2018-11-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.