Literature DB >> 18686766

Effect of blood contamination on the shear bond strength at resin/dentin interface in primary teeth.

Maria Stella Raffaini1, Jaciara Miranda Gomes-Silva, Carolina Paes Torres-Mantovani, Regina Guenka Palma-Dibb, Maria Cristina Borsatto.   

Abstract

PURPOSE: To assess in vitro the shear bond strength at the resin/dentin interface in primary teeth after contamination with fresh human blood.
METHODS: 75 crowns of primary molars were embedded in acrylic resin and mechanically ground to expose a flat dentin surface. The specimens were randomly assigned to five groups (n=15), according to the surface treatment. Group 1 (control) had no blood contamination. The other groups were blood-contaminated and subjected to different post-contamination protocols: in Group 2, the surfaces were rinsed with water; in Group 3, the surfaces were air-dried; in Group 4, the surfaces were rinsed and air-dried; and in Group 5, no post-contamination treatment was done. In all groups, a 3-mm dentin bonding site was demarcated, Single Bond adhesive system was applied and resin composite cylinders were bonded. After 24 hours in distilled water, shear bond strength was tested at a crosshead speed of 0.5 mm/minute.
RESULTS: Means (in MPa) were: Group 1: 7.1 (+/- 4.2); Group 2: 4.0 (+/- 1.8); Group 3: 0.9 (+/- 0.7); Group 4: 3.9 (+/- 2.2) and Group 5: 1.3 (+/- 1.5). Data were analyzed statistically by the Kruskal-Wallis test at 5% significance level. Groups 2 and 4 were similar to each other (P > 0.05) and both ware similar to Group 1 (P > 0.05). These groups (2, 3 and 4) had statistically significantly higher bond strengths than Groups 3 and 5 (P < 0.05). Blood contamination negatively affected the shear bond strength to primary tooth dentin. Among the blood-contaminated groups, water-rinsed specimens had higher bond strengths than those that were exclusively air-dried or not submitted to any post-contamination protocol before adhesive application.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18686766

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  5 in total

1.  Effect of gamma radiation on bonding to human enamel and dentin.

Authors:  Lucas Z Naves; Veridiana R Novais; Steven R Armstrong; Lourenço Correr-Sobrinho; Carlos J Soares
Journal:  Support Care Cancer       Date:  2012-03-14       Impact factor: 3.603

2.  Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood-Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin.

Authors:  Satheesh B Haralur; Salem Mohammed Alharthi; Saeed Aied Abohasel; Khalid Mohammed Alqahtani
Journal:  Healthcare (Basel)       Date:  2019-11-01

3.  Effect of a plant-based hemostatic agent on microleakage of self-etching adhesives.

Authors:  Soley Arslan; Hüseyin Ertaş; Yahya-Orçun Zorba
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-01-01

4.  Do blood contamination and haemostatic agents affect microtensile bond strength of dual cured resin cement to dentin?

Authors:  Kerem Kilic; Soley Arslan; Goknil Alkan Demetoglu; Gokmen Zararsiz; Bulent Kesim
Journal:  J Appl Oral Sci       Date:  2013 Jan-Feb       Impact factor: 2.698

5.  Comparative study between laser and conventional techniques for class V cavity preparation in gamma-irradiated teeth (in vitro study).

Authors:  Amr H M Rasmy; Tarek A Harhash; Rami M S Ghali; Eman M F El Maghraby; Dalia H El Rouby
Journal:  J Appl Oral Sci       Date:  2017 Nov-Dec       Impact factor: 2.698

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.