Literature DB >> 11203816

The influence of blood contamination on bond strengths between dentin and an adhesive resin cement.

T Kaneshima1, H Yatani, T Kasai, E K Watanabe, A Yamashita.   

Abstract

The objective of this study was to determine in which step of adherent surface treatments blood contamination affects the bond strength between an adhesive resin and dentin. The coronal part of bovine incisors was polished flat to expose the dentin. The specimens were randomly divided into three groups and specific surface treatments were applied to each group: (1) a self-etching primer application (SP group); (2) 38% phosphoric acid etching followed by primer (non-HC group); (3) acid etching followed by 10% sodium hypochlorite solution application and primer (HC group). The dentin surface was contaminated by human blood before or after either step of the surface treatments. The contaminated surfaces were washed with water after 30-second exposure and air-dried. A stainless-steel rod was adhered on the dentin surface with Panavia 21 after completing the surface treatment(s), and the tensile bond strength was measured. Fifteen subgroups including control groups were tested. If blood contamination occurred before collagen fibers were exposed by either phosphoric acid etching or self-etching primer application, the contamination presented almost no influence on bond strength. Blood contamination of the dentin surface where collagen fibers had been exposed decreased the bond strength. However, when the contaminated collagen fibers were dissolved or when the contamination occurred after the exposed collagen fibers were dissolved, the bond strength was maintained. The bond strength was markedly decreased when the contamination occurred after the primer application (Scheffé's Comparison, SP group: p = 0.0003, non-HC group: p < 0.0001), but was restored by reapplication of the self-etching primer. This study revealed that the effects of blood contamination on the bond strength of adhesive resin to dentin vary greatly depending on the adherent surface conditions.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11203816

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Influence of blood contamination on bond strength of a self-etching system.

Authors:  Ellen Cristina de Carvalho Mendonça; Samuel Nilo Vieira; Fernando Aparecido Kawaguchi; John Powers; Adriana Bona Matos
Journal:  Eur J Dent       Date:  2010-07

2.  Effect of Decontamination Treatments on Micro-Shear Bond Strength between Blood-Saliva-Contaminated Post-Etched Dentin Substrate and Composite Resin.

Authors:  Satheesh B Haralur; Salem Mohammed Alharthi; Saeed Aied Abohasel; Khalid Mohammed Alqahtani
Journal:  Healthcare (Basel)       Date:  2019-11-01

3.  Effect of ferric sulfate contamination on the bonding effectiveness of etch-and-rinse and self-etch adhesives to superficial dentin.

Authors:  Shahram Farzin Ebrahimi; Niloofar Shadman; Arezoo Abrishami
Journal:  J Conserv Dent       Date:  2013-03

4.  Do blood contamination and haemostatic agents affect microtensile bond strength of dual cured resin cement to dentin?

Authors:  Kerem Kilic; Soley Arslan; Goknil Alkan Demetoglu; Gokmen Zararsiz; Bulent Kesim
Journal:  J Appl Oral Sci       Date:  2013 Jan-Feb       Impact factor: 2.698

5.  Effect of saliva and blood contamination on the shear bond strength of fifth-, seventh-, and eighth-generation bonding agents: An in vitro study.

Authors:  Sonali Taneja; Manju Kumari; Shreya Bansal
Journal:  J Conserv Dent       Date:  2017 May-Jun
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.